The static codes used for information transmission
throughout the 433.92 MHz system of the Guardian 2 system allow an attacker in
proximity to monitor the movements of users inside the premises where the
sensors are set up. This is further aided by the fact that codes transmitted
reveal sensor type, although sensor location cannot be inferred from this
traffic alone.
Advisories

No advisories yet.

Fixes

Solution

Nexsmart reported suspending sales and described a phase-out of the current Guardian models. If you own an affected system and are concerned, contact Nexsmart through its official support channels and ask about any current remediation guidance.


Workaround

No workaround given by the vendor.

History

Thu, 19 Nov 2026 10:45:00 +0000

Type Values Removed Values Added
Description The static codes used for information transmission throughout the 433.92 MHz system of the Guardian 2 system allow an attacker in proximity to monitor the movements of users inside the premises where the sensors are set up. This is further aided by the fact that codes transmitted reveal sensor type, although sensor location cannot be inferred from this traffic alone.
Title Occupancy monitoring via unencrypted RF communication
Weaknesses CWE-319
References
Metrics cvssV4_0

{'score': 7.1, 'vector': 'CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N'}


Projects

Sign in to view the affected projects.

cve-icon MITRE

Status: PUBLISHED

Assigner: ENISA

Published:

Updated: 2026-11-19T10:32:13.090Z

Reserved: 2026-08-31T12:26:22.054Z

Link: CVE-2026-82949

cve-icon Vulnrichment

No data.

cve-icon NVD

No data.

cve-icon Redhat

No data.

cve-icon OpenCVE Enrichment

No data.

Weaknesses