A moved device keeps its key and certificate, joins the target organization's matching deployment groups, and is sent their firmware with a download URL, which the view role cannot otherwise obtain. The user cannot change or control devices that already belong to the other organization.
This issue affects nerves_hub: from 1.0.0 before 2.5.3.
Metrics
Affected Vendors & Products
No advisories yet.
Solution
Every move is recorded in the target product's audit log as "User moved device to : ". After upgrading, review the audit_logs rows with resource type NervesHub.Products.Product and a description containing "moved device" whose actor does not hold the manage or admin role in that organization, and move or remove the devices they brought in. Roles may have changed since a move, and entries older than the retention period are gone when TRUNCATE_AUDIT_LOGS_ENABLED is on.
Workaround
No workaround given by the vendor.
Tue, 10 Nov 2026 11:00:00 +0000
| Type | Values Removed | Values Added |
|---|---|---|
| Description | Incorrect Authorization vulnerability in the devices page bulk move in nerves-hub nerves_hub_web allows an authenticated user with the manage role in one organization and only the view role in another to move devices into the second organization's product via the "Move device(s) to product" action. The target-product event in NervesHubWeb.Live.Devices.Index looks the product up with NervesHub.Products.get_by_id/2, which checks that the user is a member of the product's organization at any role, and move-devices-product then changes each selected device's organization and product. The device API's move requires manage in the target organization, and an earlier fix added the check on the organization the devices leave but not on the one they enter. A moved device keeps its key and certificate, joins the target organization's matching deployment groups, and is sent their firmware with a download URL, which the view role cannot otherwise obtain. The user cannot change or control devices that already belong to the other organization. This issue affects nerves_hub: from 1.0.0 before 2.5.3. | |
| Title | Incorrect authorization in the devices page bulk move allows view-role members to move devices into another organization and receive its firmware | |
| First Time appeared |
Nerves-hub
Nerves-hub nerves Hub Web |
|
| Weaknesses | CWE-863 | |
| CPEs | cpe:2.3:a:nerves-hub:nerves_hub_web:*:*:*:*:*:*:*:* | |
| Vendors & Products |
Nerves-hub
Nerves-hub nerves Hub Web |
|
| References |
|
|
| Metrics |
cvssV4_0
|
Projects
Sign in to view the affected projects.
Status: PUBLISHED
Assigner: EEF
Published:
Updated: 2026-11-10T10:43:26.342Z
Reserved: 2026-11-06T09:58:06.998Z
Link: CVE-2026-120295
No data.
Status : Received
Published: 2026-11-10T11:16:41.960
Modified: 2026-11-10T11:16:41.960
Link: CVE-2026-120295
No data.
OpenCVE Enrichment
No data.