Search Results (15 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2026-81532 1 Mongodb 1 Bi Connector Odbc Driver 2026-08-29 8.8 High
A user able to submit SQL through an application using the MongoDB Connector for BI ODBC driver can supply a positioned-cursor statement whose cursor name exceeds the size of an internal fixed-length buffer. Because the name length is not bounded before the driver builds its diagnostic message, memory adjacent to that buffer is overwritten with user-supplied content. This can terminate the hosting application process and may allow unintended code to run within it.
CVE-2026-81533 1 Mongodb 1 Bi Connector Odbc Driver 2026-08-29 7.1 High
An application using the MongoDB BI Connector ODBC Driver may encounter a memory-safety issue when a submitted SQL statement contains an unusually long run of digits following a LIMIT clause. The issue occurs only on connections where the driver's optional prefetch setting is enabled, and stems from the driver copying the digit sequence into a fixed-size internal buffer without checking its length. A user able to influence the numeric portion of a LIMIT clause could cause the hosting application process to terminate unexpectedly or corrupt adjacent memory in that process.
CVE-2026-81520 1 Mongodb 1 Bi Connector 2026-08-29 7.5 High
A network-reachable client that has not yet authenticated can hold a MongoDB Connector for BI authentication session open indefinitely by beginning a SASL-based login exchange and then declining to complete it. Because the negotiation loop had no overall time bound and the read from the client had no deadline, each such session retains a worker, a client connection slot, and its associated backend database connections until the process is restarted. Repeated use of this behavior can consume the configured connection capacity and prevent legitimate users from establishing new sessions.
CVE-2026-81490 1 Mongodb 1 Bi Connector 2026-08-29 7.7 High
A database user able to create a view in a namespace that MongoDB Connector for BI samples can cause the schema-sampling routine to stop functioning by defining a view whose evaluation reliably fails. The sampling logic classifies the resulting server message as transient and, after the configured retries are exhausted, proceeds without a valid result, ending the schema refresh routine. The mongosqld process continues running without a usable schema, so SQL clients are unable to obtain results until an operator removes the view or excludes its namespace from sampling.
CVE-2026-81517 1 Mongodb 1 Bi Connector 2026-08-29 7.5 High
An unauthenticated party able to reach the port of a MongoDB Connector for BI (mongosqld) instance may generate enough routine connection log activity to exhaust the storage backing the configured log path. When a log write or log rotation operation subsequently fails, the resulting error is not handled and the shared mongosqld process ends, ending service for all connected SQL clients. The process continues to end on startup until an operator restores available storage, and the diagnostic message explaining the condition is not recorded.
CVE-2026-81518 1 Mongodb 1 Bi Connector 2026-08-29 7.5 High
When mongosqld is configured with a client certificate authority file, the listener requests a client certificate during the TLS handshake but does not require one, so a client that presents no certificate is still accepted. In deployments that rely on client certificates as the sole means of identifying users, a remote party with network access to the listener can therefore establish a session and read the MongoDB data exposed through the connector.
CVE-2026-77184 1 Mongodb 1 Bi Connector 2026-08-28 5.2 Medium
In MongoDB Connector for BI, the description text of a collection's JSON schema validator is incorporated into the comment text of the DDL returned by SHOW CREATE statements without complete escaping of backslash characters. A user with permission to modify a collection's schema validator, in deployments configured to build their SQL schema from those validators, can cause additional SQL text to be embedded in that generated output. If an operator or automated tool later replays that generated statement against a SQL server, the additional text is executed with the privileges of that session.
CVE-2026-77586 1 Mongodb 1 Bi Connector 2026-08-28 8 High
In MongoDB Connector for BI, MongoDB object names such as collection, field, and index names are placed into the quoted identifiers of the DDL text returned by SHOW CREATE statements without escaping the identifier delimiter. A user with permission to write to a sampled MongoDB collection can choose a name that closes the quoted identifier early, so that additional SQL text becomes part of the generated output. If an operator or automated tool later replays that generated statement against a SQL server, the additional text is executed with the privileges of that session.
CVE-2026-75159 1 Mongodb 1 Bi Connector 2026-08-28 5.9 Medium
An unauthenticated client that can reach a MongoDB Connector for BI deployment configured with Kerberos authentication may cause mongosqld to terminate when a crafted authentication exchange encounters a specific GSSAPI error-handling condition. This can interrupt BI Connector availability until the process restarts.
CVE-2026-75573 1 Mongodb 1 Bi Connector 2026-08-28 4.4 Medium
In MongoDB Connector for BI, mongodrdl may write a TLS private-key password to standard error when the password is supplied through both the connection URI and the corresponding command-line option. A local user with access to the captured command output and encrypted key file may use the disclosed password to access the associated TLS client key.
CVE-2026-19004 1 Mongodb 1 Bi Connector Odbc Driver 2026-08-13 8.1 High
An application using the MongoDB BI Connector ODBC Driver may experience a memory-safety issue when processing output parameters from a stored procedure. Triggering this issue requires connecting to an untrusted or impersonated database server that returns crafted metadata. This may result in process termination, disclosure of process memory, or, under certain conditions, arbitrary code execution.
CVE-2026-18888 1 Mongodb 1 Bi Connector Odbc Driver 2026-08-13 6.5 Medium
The MongoDB BI Connector ODBC Driver converts floating point column values into text without checking that the result fits within the destination buffer. When an application reads a sufficiently large floating point value as text, the driver may write beyond the end of that buffer and corrupt adjacent memory. A user who can store data in a collection read through the BI Connector could use this to crash the application performing the read.
CVE-2026-19003 1 Mongodb 1 Bi Connector Odbc Driver 2026-08-13 7.8 High
A data source definition containing an over-length file path setting may cause the MongoDB BI Connector ODBC Driver setup dialog to write outside the bounds of an allocated buffer. The issue stems from an incorrect buffer capacity calculation in the dialog's file and folder selection handling, and is reached only when a user opens the setup dialog for such a data source and initiates a file or folder selection. Depending on build configuration, the result may range from abnormal process termination to, under certain conditions, execution of unintended code in the context of the user running the dialog.
CVE-2026-19002 1 Mongodb 1 Bi Connector Odbc Driver 2026-08-13 8.1 High
A missing bounds check when parsing stored procedure parameter metadata in the MongoDB BI Connector ODBC Driver can result in an out-of-bounds write in the client application process. Triggering this issue requires control over the server the driver connects to, or the ability to respond in its place, in order to return malformed metadata. The resulting memory corruption may cause the client application to terminate abnormally or, under certain conditions, execute unintended code.
CVE-2026-19001 1 Mongodb 1 Bi Connector Odbc Driver 2026-08-13 9.8 Critical
The MongoDB BI Connector ODBC Driver may write outside the bounds of a fixed-size buffer when an application supplies an unusually long catalog, schema, or object name to a metadata retrieval function. This may result in memory corruption within the calling application's process, leading to abnormal termination and, under certain conditions, the potential for arbitrary code execution.