CVE-2023-52335 1 Advantech 1 Iview 2025-01-09 7.5 High
Advantech iView ConfigurationServlet SQL Injection Information Disclosure Vulnerability. This vulnerability allows remote attackers to disclose sensitive information on affected installations of Advantech iView. Authentication is not required to exploit this vulnerability. The specific flaw exists within the ConfigurationServlet servlet, which listens on TCP port 8080 by default. When parsing the column_value element, the process does not properly validate a user-supplied string before using it to construct SQL queries. An attacker can leverage this vulnerability to disclose stored credentials, leading to further compromise. Was ZDI-CAN-17863.
CVE-2023-32628 1 Advantech 1 Webaccess\/scada 2025-01-08 7.2 High
In Advantech WebAccss/SCADA v9.1.3 and prior, there is an arbitrary file upload vulnerability that could allow an attacker to modify the file extension of a certificate file to ASP when uploading it, which can lead to remote code execution.
CVE-2023-32540 1 Advantech 1 Webaccess\/scada 2025-01-08 7.2 High
In Advantech WebAccss/SCADA v9.1.3 and prior, there is an arbitrary file overwrite vulnerability, which could allow an attacker to overwrite any file in the operating system (including system files), inject code into an XLS file, and modify the file extension, which could lead to arbitrary code execution.
CVE-2023-22450 1 Advantech 1 Webaccess\/scada 2025-01-08 7.2 High
In Advantech WebAccss/SCADA v9.1.3 and prior, there is an arbitrary file upload vulnerability that could allow an attacker to upload an ASP script file to a webserver when logged in as manager user, which can lead to arbitrary code execution.
CVE-2024-50367 1 Advantech 3 Eki-6333ac-1gpo Firmware, Eki-6333ac-2g Firmware, Eki-6333ac-2gd Firmware 2024-11-26 7.2 High
A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The source of the vulnerability relies on multiple parameters belonging to the "sta_log_htm" API which are not properly sanitized before being concatenated to OS level commands.
CVE-2024-50362 1 Advantech 3 Eki-6333ac-1gpo Firmware, Eki-6333ac-2g Firmware, Eki-6333ac-2gd Firmware 2024-11-26 7.2 High
A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The source of the vulnerability relies on multiple parameters belonging to the "connection_profile_apply" API which are not properly sanitized before being concatenated to OS level commands.
CVE-2024-50361 1 Advantech 3 Eki-6333ac-1gpo Firmware, Eki-6333ac-2g Firmware, Eki-6333ac-2gd Firmware 2024-11-26 7.2 High
A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The source of the vulnerability relies on multiple parameters belonging to the "certificate_file_remove" API which are not properly sanitized before being concatenated to OS level commands.
CVE-2024-50363 1 Advantech 3 Eki-6333ac-1gpo Firmware, Eki-6333ac-2g Firmware, Eki-6333ac-2gd Firmware 2024-11-26 7.2 High
A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The source of the vulnerability relies on multiple parameters belonging to the "mp_apply" API which are not properly sanitized before being concatenated to OS level commands.
CVE-2024-50364 1 Advantech 3 Eki-6333ac-1gpo Firmware, Eki-6333ac-2g Firmware, Eki-6333ac-2gd Firmware 2024-11-26 7.2 High
A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The source of the vulnerability relies on multiple parameters belonging to the "export_log" API which are not properly sanitized before being concatenated to OS level commands.
CVE-2024-50365 1 Advantech 3 Eki-6333ac-1gpo Firmware, Eki-6333ac-2g Firmware, Eki-6333ac-2gd Firmware 2024-11-26 7.2 High
A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The source of the vulnerability relies on multiple parameters belonging to the "lan_apply" API which are not properly sanitized before being concatenated to OS level commands.
CVE-2024-50359 1 Advantech 3 Eki-6333ac-1gpo Firmware, Eki-6333ac-2g Firmware, Eki-6333ac-2gd Firmware 2024-11-26 7.2 High
A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The source of the vulnerability relies on multiple parameters belonging to the "scan_ap" API which are not properly sanitized before being concatenated to OS level commands.
CVE-2024-50360 1 Advantech 3 Eki-6333ac-1gpo Firmware, Eki-6333ac-2g Firmware, Eki-6333ac-2gd Firmware 2024-11-26 7.2 High
A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The source of the vulnerability relies on multiple parameters belonging to the "snmp_apply" API which are not properly sanitized before being concatenated to OS level commands.
CVE-2024-50366 1 Advantech 3 Eki-6333ac-1gpo Firmware, Eki-6333ac-2g Firmware, Eki-6333ac-2gd Firmware 2024-11-26 7.2 High
A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The source of the vulnerability relies on multiple parameters belonging to the "applications_apply" API which are not properly sanitized before being concatenated to OS level commands.
CVE-2024-50371 1 Advantech 3 Eki-6333ac-1gpo Firmware, Eki-6333ac-2g Firmware, Eki-6333ac-2gd Firmware 2024-11-26 9.8 Critical
A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The vulnerability can be exploited by remote unauthenticated users capable of interacting with the default "edgserver" service enabled on the access point and malicious commands are executed with root privileges. No authentication is enabled on the service and the source of the vulnerability resides in processing code associated to the "wlan_scan" operation.
CVE-2024-50372 1 Advantech 3 Eki-6333ac-1gpo Firmware, Eki-6333ac-2g Firmware, Eki-6333ac-2gd Firmware 2024-11-26 9.8 Critical
A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The vulnerability can be exploited by remote unauthenticated users capable of interacting with the default "edgserver" service enabled on the access point and malicious commands are executed with root privileges. No authentication is enabled on the service and the source of the vulnerability resides in processing code associated to the "backup_config_to_utility" operation.
CVE-2024-50373 1 Advantech 3 Eki-6333ac-1gpo Firmware, Eki-6333ac-2g Firmware, Eki-6333ac-2gd Firmware 2024-11-26 9.8 Critical
A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The vulnerability can be exploited by remote unauthenticated users capable of interacting with the default "edgserver" service enabled on the access point and malicious commands are executed with root privileges. No authentication is enabled on the service and the source of the vulnerability resides in processing code associated to the "restore_config_from_utility" operation.
CVE-2024-50374 1 Advantech 3 Eki-6333ac-1gpo Firmware, Eki-6333ac-2g Firmware, Eki-6333ac-2gd Firmware 2024-11-26 9.8 Critical
A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The vulnerability can be exploited by remote unauthenticated users capable of interacting with the default "edgserver" service enabled on the access point and malicious commands are executed with root privileges. No authentication is enabled on the service and the source of the vulnerability resides in processing code associated to the "capture_packages" operation.
CVE-2024-50375 1 Advantech 3 Eki-6333ac-1gpo Firmware, Eki-6333ac-2g Firmware, Eki-6333ac-2gd Firmware 2024-11-26 9.8 Critical
A CWE-306 "Missing Authentication for Critical Function" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The vulnerability can be exploited by remote unauthenticated users capable of interacting with the default "edgserver" service enabled on the access point.
CVE-2024-50377 1 Advantech 3 Eki-6333ac-1gpo Firmware, Eki-6333ac-2g Firmware, Eki-6333ac-2gd Firmware 2024-11-26 6.5 Medium
A CWE-798 "Use of Hard-coded Credentials" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The vulnerability is associated to the backup configuration functionality that by default encrypts the archives using a static password.
CVE-2023-5642 1 Advantech 1 R-seenet 2024-11-21 9.8 Critical
Advantech R-SeeNet v2.4.23 allows an unauthenticated remote attacker to read from and write to the snmpmon.ini file, which contains sensitive information.