| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| An attacker could exploit this vulnerability in Hitachi ABB Power Grids Ellipse Enterprise Asset Management (EAM) versions prior to and including 9.0.25 by tricking a user to click on a link containing malicious code that would then be run by the web browser. This can result in the compromise of confidential information, or even the takeover of the user’s session. |
| Axeda agent (All versions) and Axeda Desktop Server for Windows (All versions) uses hard-coded credentials for its UltraVNC installation. Successful exploitation of this vulnerability could allow a remote authenticated attacker to take full remote control of the host operating system. |
| Rockwell Automation ISaGRAF Runtime Versions 4.x and 5.x includes the functionality of setting a password that is required to execute privileged commands. The password value passed to ISaGRAF Runtime is the result of encryption performed with a fixed key value using the tiny encryption algorithm (TEA) on an entered or saved password. A remote, unauthenticated attacker could pass their own encrypted password to the ISaGRAF 5 Runtime, which may result in information disclosure on the device. |
| By having access to the hard-coded cryptographic key for GE Reason RT430, RT431 & RT434 GNSS clocks in firmware versions prior to version 08A06, attackers would be able to intercept and decrypt encrypted traffic through an HTTPS connection. |
| GE UR firmware versions prior to version 8.1x supports web interface with read-only access. The device fails to properly validate user input, making it possible to perform cross-site scripting attacks, which may be used to send a malicious script. Also, UR Firmware web server does not perform HTML encoding of user-supplied strings. |
| A reflected cross-site scripting (XSS) vulnerability in the B. Braun Melsungen AG SpaceCom Version L81/U61 and earlier, and the Data module compactplus Versions A10 and A11 allows remote attackers to inject arbitrary web script or HTML into various locations. |
| Hard-coded credentials in the B. Braun Melsungen AG SpaceCom Version L81/U61 and earlier, and the Data module compactplus Versions A10 and A11 enable attackers with command line access to access the device’s Wi-Fi module. |
| An attacker may be able to inject client-side JavaScript code on multiple instances within all versions of Uffizio GPS Tracker. |
| The Weintek cMT product line is vulnerable to a cross-site scripting vulnerability, which could allow an unauthenticated remote attacker to inject malicious JavaScript code. |
| xArrow SCADA versions 7.2 and prior is vulnerable to cross-site scripting due to parameter ‘bdate’ of the resource xhisvalue.htm, which may allow an unauthorized attacker to execute arbitrary code. |
| xArrow SCADA versions 7.2 and prior is vulnerable to cross-site scripting due to parameter ‘edate’ of the resource xhisalarm.htm, which may allow an unauthorized attacker to execute arbitrary code. |
| xArrow SCADA versions 7.2 and prior permits unvalidated registry keys to be run with application-level privileges. |
| The AGG Software Web Server version 4.0.40.1014 and prior is vulnerable to cross-site scripting, which may allow an attacker to remotely execute arbitrary code. |
| When a non-existent resource is requested, the LCDS LAquis SCADA application (version 4.3.1.1011 and prior) returns error messages which may allow reflected cross-site scripting. |
| An attacker can gain full access (read/write/delete) to sensitive folders due to hard-coded credentials on KUKA KR C4 control software for versions prior to 8.7 or any product running KSS. |
| A vulnerability was found in GE Voluson S8. It has been rated as critical. This issue affects the Service Browser which itroduces hard-coded credentials. Attacking locally is a requirement. It is recommended to change the configuration settings. |
| A user with administrative privileges in Distributed Data Systems WebHMI 4.1.1.7662 can store a script that could impact other logged in users. |
| A Stored Cross-site scripting (XSS) vulnerability via MAster.php in Sourcecodetester Simple Client Management System (SCMS) 1.0 allows remote attackers to inject arbitrary web script or HTML via the vulnerable input fields. |
| The MiCODUS MV720 GPS tracker API server has an authentication mechanism that allows devices to use a hard-coded master password. This may allow an attacker to send SMS commands directly to the GPS tracker as if they were coming from the GPS owner’s mobile number. |
| Multiple globally default credentials exist across all CMS8000 devices, that once exposed, allow a threat actor with momentary physical access to gain privileged access to any device. Privileged credential access enables the extraction of sensitive patient information or modification of device parameters |