| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| Tenda AC10U v1.0 US_AC10UV1.0RTL_V15.03.06.49_multi_TDE01 was discovered to contain a stack overflow via the ssid parameter in the form_fast_setting_wifi_set function. |
| Tenda AC10U v1.0 US_AC10UV1.0RTL_V15.03.06.49_multi_TDE01 was discovered to contain a stack overflow via the speed_dir parameter in the formSetSpeedWan function. |
| Tenda AC10U v1.0 US_AC10UV1.0RTL_V15.03.06.49_multi_TDE01 was discovered to contain a stack overflow via the formSetClientState function. |
| Tenda AC10U v1.0 US_AC10UV1.0RTL_V15.03.06.49_multi_TDE01 was discovered to contain a stack overflow via the security parameter in the formWifiBasicSet function. |
| Tenda AC10U v1.0 US_AC10UV1.0RTL_V15.03.06.49_multi_TDE01 was discovered to contain a stack overflow via the mac parameter in the GetParentControlInfo function. |
| Tenda AC10U v1.0 US_AC10UV1.0RTL_V15.03.06.49_multi_TDE01 was discovered to contain a stack overflow via the domain parameter in the add_white_node function. |
| Tenda AC10U v1.0 US_AC10UV1.0RTL_V15.03.06.49_multi_TDE01 was discovered to contain a stack overflow via the timeZone parameter in the fromSetSysTime function. |
| Tenda AC10U v1.0 US_AC10UV1.0RTL_V15.03.06.49_multi_TDE01 was discovered to contain a stack overflow via the deviceId parameter in the addWifiMacFilter function. |
| Tenda AC10U v1.0 US_AC10UV1.0RTL_V15.03.06.49_multi_TDE01 was discovered to contain a stack overflow via the schedEndTime parameter in the setSchedWifi function. |
| Tenda AC10U v1.0 US_AC10UV1.0RTL_V15.03.06.49_multi_TDE01 was discovered to contain multiple stack overflows in the formSetMacFilterCfg function via the macFilterType and deviceList parameters. |
| Tenda AC10U v1.0 US_AC10UV1.0RTL_V15.03.06.49_multi_TDE01 was discovered to contain a stack overflow via the list parameter in the fromSetIpMacBind function. |
| A stack based buffer overflow exists in Delta Electronics Delta Industrial Automation DOPSoft when parsing the wTitleTextLen field of a DPS file. A remote, unauthenticated attacker can exploit this vulnerability by enticing a user to open a specially crafted DPS file to achieve remote code execution. |
| A stack based buffer overflow exists in Delta Electronics Delta Industrial Automation DOPSoft when parsing the wLogTitlesActionLen field of a DPS file. A remote, unauthenticated attacker can exploit this vulnerability by enticing a user to open a specially crafted DPS file to achieve remote code execution.
|
| A stack based buffer overflow exists in Delta Electronics Delta Industrial Automation DOPSoft when parsing the wLogTitlesPrevValueLen field of a DPS file. A remote, unauthenticated attacker can exploit this vulnerability by enticing a user to open a specially crafted DPS file to achieve remote code execution. |
| A buffer overflow vulnerability exists in Delta Electronics Delta Industrial Automation DOPSoft version 2 when parsing the wKPFStringLen field of a DPS file. An anonymous attacker can exploit this vulnerability by enticing a user to open a specially crafted DPS file to achieve code execution.
|
| An issue was discovered in Croc through 9.6.5. A sender may place ANSI or CSI escape sequences in a filename to attack the terminal device of a receiver. |
| Improper restriction of operations within the bounds of a memory buffer issue exists in OnSinView2 versions 2.0.1 and earlier. If this vulnerability is exploited, information may be disclosed or arbitrary code may be executed by having a user open a specially crafted OnSinView2 project file. |
| lockss-daemon (aka Classic LOCKSS Daemon) before 1.77.3 performs post-Unicode normalization, which may allow bypass of intended access restrictions, such as when U+1FEF is converted to a backtick. |
| SHIRASAGI is a Content Management System. Prior to version 1.18.0, SHIRASAGI is vulnerable to a Post-Unicode normalization issue. This happens when a logical validation or a security check is performed before a Unicode normalization. The Unicode character equivalent of a character would resurface after the normalization. The fix is initially performing the Unicode normalization and then strip for all whitespaces and then checking for a blank string. This issue has been fixed in version 1.18.0.
|
| A vulnerability has been identified in Tecnomatix Plant Simulation V2201 (All versions < V2201.0008), Tecnomatix Plant Simulation V2302 (All versions < V2302.0002). The affected application is vulnerable to memory corruption while parsing specially crafted SPP files. This could allow an attacker to execute code in the context of the current process. |