| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| Ever Traduora 0.20.0 and below is vulnerable to Privilege Escalation due to the use of a hard-coded JWT signing key. |
| CWE-798 Use of Hard-coded Credentials |
| A vulnerability in the .sdd file allows an attacker to read default passwords stored in plain text within the code. By exploiting these plaintext credentials, an attacker can log into affected SICK products as an “Authorized Client” if the customer has not changed the default password. |
| Cypress Solutions CTM-200/CTM-ONE 1.3.6 contains hard-coded credentials vulnerability in Linux distribution that exposes root access. Attackers can exploit the static 'Chameleon' password to gain remote root access via Telnet or SSH on affected devices. |
| The `/etc/passwd` and `/etc/shadow` files reveal hard-coded password hashes for the operating system "root" user. The credentials are shipped with the update files. There is no option for deleting or changing their passwords for an enduser. An attacker can use the credentials to log into the device. Authentication can be performed via SSH backdoor or likely via physical access (UART shell). |
| All the Toshiba printers contain a shell script using the same hardcoded key to encrypt logs. An attacker can decrypt the encrypted files using the hardcoded key. This vulnerability can be executed in combination with other vulnerabilities and difficult to execute alone. So, the CVSS score for this vulnerability alone is lower than the score listed in the "Base Score" of this vulnerability. For detail on related other vulnerabilities, please ask to the below contact point.
https://www.toshibatec.com/contacts/products/
As for the affected products/models/versions, see the reference URL. |
| Deck Mate 2 is distributed with static, hard-coded credentials for the root shell and web user interface, while multiple management services (SSH, HTTP, Telnet, SMB, X11) are enabled by default. If an attacker can reach these interfaces - most often through local or near-local access such as connecting to the USB or Ethernet ports beneath the table - the built-in credentials permit administrative login and full control of the system. Once authenticated, an attacker can access firmware utilities, modify controller software, and establish persistent compromise. Remote attack paths via network, cellular, or telemetry links may exist in specific configurations but generally require additional capabilities or operator error. The vendor reports that USB access has been disabled in current firmware builds. |
| An authentication bypass vulnerability in the /web/um_open_telnet.cgi endpoint in Nexxt Solutions NCM-X1800 Mesh Router firmware UV1.2.7 and below, allowing an attacker to remotely enable the Telnet service without authentication, bypassing security controls. The Telnet server is then accessible with hard-coded credentials, allowing attackers to gain administrative shell access and execute arbitrary commands on the device. |
| all the Toshiba printers have programs containing a hardcoded key used to encrypt files. An attacker can decrypt the encrypted files using the hardcoded key. Insecure algorithm is used for the encryption. This vulnerability can be executed in combination with other vulnerabilities and difficult to execute alone. So, the CVSS score for this vulnerability alone is lower than the score listed in the "Base Score" of this vulnerability. For detail on related other vulnerabilities, please ask to the below contact point.
https://www.toshibatec.com/contacts/products/
As for the affected products/models/versions, see the reference URL. |
| A vulnerability exists in multiple Radiometer products that allow an attacker with physical access to the analyzer possibility to extract credential information. The vulnerability is due to a weakness in the design and insufficient credential protection in operating system.
Other related CVE's are CVE-2025-14095 & CVE-2025-14097.
Affected customers have been informed about this vulnerability. This CVE is being published to provide transparency.
Required Configuration for Exposure:
Attacker requires physical access to the analyzer.
Temporary work Around:
Only authorized people can physically access the analyzer.
Permanent solution:
Local Radiometer representatives will contact all affected customers to discuss a permanent solution.
Exploit Status:
Researchers have provided a working proof-of-concept (PoC). Radiometer is not aware of any public exploit code at the time of this publication. |
| A vulnerability has been found in TOZED ZLT M30S and ZLT M30S PRO 1.47/3.09.06. Affected is an unknown function of the component Web Interface. Such manipulation leads to hard-coded credentials. The attack needs to be initiated within the local network. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way. |
| An issue was discovered in the G-Net GNET APK 2.6.2. Hardcoded credentials exist in in APK for ports 9091 and 9092. The GNET mobile application contains hardcoded credentials that provide unauthorized access to the dashcam's API endpoints on ports 9091 and 9092. Once the GNET SSID is connected to, the attacker sends a crafted authentication command with TibetList and 000000 to list settings of the dashcam at port 9091. There's a separate set of credentials for port 9092 (stream) that is also exposed in cleartext: admin + tibet. For settings, the required credentials are adim + 000000. |
| A predefined administrative account is not documented and cannot
be deactivated. This account cannot be misused from the network, only by local
users on the server. |
| Use of Hard-coded Credentials vulnerability in GoodWe Technologies Co., Ltd. GW1500‑XS allows anyone in physical proximity to the device to fully access the web interface of the inverter via Wi‑Fi.This issue affects GW1500‑XS: 1.1.2.1. |
| Use of Hard-coded Credentials, Authorization Bypass Through User-Controlled Key vulnerability in PosCube Hardware Software and Consulting Ltd. Co. Assist allows Excavation, Authentication Bypass.This issue affects Assist: through 10.02.2025. |
| The firmware of all Wattsense Bridge devices contain the same hard-coded user and root credentials. The user password can be easily recovered via password cracking attempts. The recovered credentials can be used to log into the device via the login shell that is exposed by the serial interface. The backdoor user has been removed in firmware BSP >= 6.4.1. |
| Hardcoded credentials in gsigel14 ATLAS-EPIC commit f29312c (2025-05-26). |
| An unauthenticated remote attacker can use the hard-coded credentials to access the SmartSPS devices with high privileges.
|
| An issue was discovered on Marbella KR8s Dashcam FF 2.0.8 devices. All dashcams were shipped with the same default credentials of 12345678, which creates an insecure-by-default condition. For users who change their passwords, it's limited to 8 characters. These short passwords can be cracked in 8 hours via low-end commercial cloud resources. |
| Vulnerabilities* in ActADUR local server product, developed and maintained by ProTNS, allows Remote Code Inclusion on host systems.
* vulnerabilities:
*
Improper Neutralization of Special Elements used in a Command ('Command Injection')
* Use of Hard-coded Credentials
* Improper Authentication
* Binding to an Unrestricted IP Address
The vulnerability has been rated as critical.This issue affects ActADUR: from v2.0.1.9 before v2.0.2.0., hence updating to version v2.0.2.0. or above is required. |