| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| An issue in Debezium Community debezium-ui v.2.5 allows a local attacker to execute arbitrary code via the refresh page function. |
| This vulnerability exists in Digisol Router (DG-GR1321: Hardware version 3.7L; Firmware version : v3.2.02) due to lack of encryption or hashing in storing of passwords within the router's firmware/ database. An attacker with physical access could exploit this by extracting the firmware and reverse engineer the binary data to access the plaintext passwords on the vulnerable system.
Successful exploitation of this vulnerability could allow the attacker to gain unauthorized access to the targeted system. |
| A weakness has been identified in Intelbras UnniTI 24.07.11. The affected element is an unknown function of the file /xml/sistema/usuarios.xml. Executing manipulation of the argument Usuario/Senha can lead to unprotected storage of credentials. The attack can be executed remotely. The exploit has been made available to the public and could be exploited. |
| SAP GUI for Windows allows an unauthenticated attacker to exploit insecure obfuscation algorithms used by the GuiXT application to store user credentials. While this issue does not impact the Integrity or Availability of the application, it may have a Low impact on the Confidentiality of data. |
| LITEON IC48A firmware versions prior to 01.00.19r and LITEON IC80A firmware versions prior to 01.01.12e store FTP-server-access-credentials in cleartext in their system logs. |
|
In AutomationDirect C-MORE EA9 HMI,
credentials used by the platform are stored as plain text on the device.
|
| After gaining access to the firmware of a charging station, a file at <redacted> can be accessed to obtain default credentials that are the same across all Iocharger AC model EV chargers.
This issue affects Iocharger firmware for AC models before firmware version 25010801.
The issue is addressed by requiring a mandatory password change on first login, it is still recommended to change the password on older models.
Likelihood: Moderate – The attacker will first have to abuse a code execution or file inclusion vulnerability (for example by using <redacted>.sh) to gain access to the <redacted>.json file, or obtain a firmware dump of the charging station or obtain the firmware via other channels.
Impact: Critical – All chargers using Iocharger firmware for AC models started with the same initial password. For models with firmware version before 25010801 a password change was not mandatory. It is therefore very likely that this firmware password is still active on many chargers. These credentials could, once obtained, allow an attacker to log into many Iocharger charging station, and allow them to execute arbitrary commands via the System → Custom page.
CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, and requires high privileges (PR:H), there is no user interaction required (UI:N). The attack leads to a compromised of the confidentialy of the "super user" credentials of the device (VC:H/VI:N/VA:N), and can subsequently be used to full compromise and other devices (SC:H/SI:H/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y). |
| A vulnerability exists in the SOAP Web services of the Asset
Suite versions listed below. If successfully exploited, an attacker
could gain unauthorized access to the product and the time window of a possible password attack could be expanded. |
| Certain models of routers from Billion Electric has a Plaintext Storage of a Password vulnerability. Remote attackers with administrator privileges can access the user settings page to retrieve plaintext passwords. |
| User passwords are decrypted and stored on memory before any user logged in. Those decrypted passwords can be retrieved from the coredump file. As for the details of affected product names, model numbers, and versions, refer to the information provided by the respective vendors listed under [References]. |
| The access control in CemiPark software stores integration (e.g. FTP or SIP) credentials in plain-text. An attacker who gained unauthorized access to the device can retrieve clear text passwords used by the system.This issue affects CemiPark software: 4.5, 4.7, 5.03 and potentially others. The vendor refused to provide the specific range of affected products.
|
| The BackWPup plugin for WordPress is vulnerable to Plaintext Storage of Backup Destination Password in all versions up to, and including, 4.0.2. This is due to to the plugin improperly storing backup destination passwords in plaintext. This makes it possible for authenticated attackers, with administrator-level access, to retrieve the password from the password input field in the UI or from the options table where the password is stored. |
| NATS-Server is a High-Performance server for NATS.io, a cloud and edge native messaging system. Prior to versions 2.11.15 and 2.12.6, for MQTT deployments using usercodes/passwords: MQTT passwords are incorrectly classified as a non-authenticating identity statement (JWT) and exposed via monitoring endpoints. Versions 2.11.14 and 2.12.6 contain a fix. As a workaround, ensure monitoring end-points are adequately secured. Best practice remains to not expose the monitoring endpoint to the Internet or other untrusted network users. |
| IBM InfoSphere Information Server 11.7.0.0 through 11.7.1.6 product stores user credentials and other sensitive information in plain text which can be read by a local user. |
| Ksenia Security lares (legacy model) Home Automation version 1.6 contains an unprotected endpoint vulnerability that allows authenticated attackers to upload MPFS File System binary images. Attackers can exploit this vulnerability to overwrite flash program memory and potentially execute arbitrary code on the home automation system's web server. |
| An issue in the reset_pj.cgi endpoint of Weintek cMT-3072XH2 easyweb v2.1.53, OS v20231011 allows unauthorized attackers to execute arbitrary commands via supplying a crafted GET request. |
| Brocade SANnav before Brocade SANnav 2.4.0b logs database passwords in clear text in the standby SANnav server, after disaster recovery failover. The vulnerability could allow a remote authenticated attacker with admin privilege able to access the SANnav logs or the supportsave to read the database password. |
| Dell CloudLink, versions prior to 8.1.1, contain a vulnerability where a privileged user may exploit and gain parallel privilege escalation or access to the database to obtain confidential information. |
| IBM Db2 for Linux, UNIX and Windows (includes Db2 Connect Server) 11.5.0 through 11.5.9 and 12.1.0 through 12.1.3 could allow an authenticated user to obtain sensitive information under specific HADR configuration. |
| Several credentials for the local PostgreSQL database are stored in plain text (partially base64 encoded). |