| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| An issue was discovered on Humax Digital HG100R 2.0.6 devices. To download the backup file it's not necessary to use credentials, and the router credentials are stored in plaintext inside the backup, aka GatewaySettings.bin. |
| Apache OpenMeetings 1.0.0 uses not very strong cryptographic storage, captcha is not used in registration and forget password dialogs and auth forms missing brute force protection. |
| It was discovered that the fix for CVE-2017-12150 was not properly shipped in erratum RHSA-2017:2858 for Red Hat Gluster Storage 3.3 for RHEL 6. |
| It was discovered that the fix for CVE-2017-12151 was not properly shipped in erratum RHSA-2017:2858 for Red Hat Gluster Storage 3.3 for RHEL 6. |
| Weak access control methods on the TP-Link TL-SG108E 1.0.0 allow any user on a NAT network with an authenticated administrator to access the device without entering user credentials. The authentication record is stored on the device; thus if an administrator authenticates from a NAT network, the authentication applies to the IP address of the NAT gateway, and any user behind that NAT gateway is also treated as authenticated. |
| The admin terminal in Hawt.io does not require authentication, which allows remote attackers to execute arbitrary commands via the k parameter. |
| A vulnerability was discovered in Siemens OZW672 (all versions) and OZW772 (all versions) that could allow an attacker to read and manipulate data in TLS sessions while performing a man-in-the-middle (MITM) attack on the integrated web server on port 443/tcp. |
| OSRAM SYLVANIA Osram Lightify Home before 2016-07-26 allows remote attackers to execute arbitrary commands via TCP port 4000. |
| An unintended cleartext issue exists in Go before 1.8.4 and 1.9.x before 1.9.1. RFC 4954 requires that, during SMTP, the PLAIN auth scheme must only be used on network connections secured with TLS. The original implementation of smtp.PlainAuth in Go 1.0 enforced this requirement, and it was documented to do so. In 2013, upstream issue #5184, this was changed so that the server may decide whether PLAIN is acceptable. The result is that if you set up a man-in-the-middle SMTP server that doesn't advertise STARTTLS and does advertise that PLAIN auth is OK, the smtp.PlainAuth implementation sends the username and password. |
| An issue was discovered in BINOM3 Universal Multifunctional Electric Power Quality Meter. Lack of authentication for remote service gives access to application set up and configuration. |
| firewalld.py in firewalld before 0.4.3.3 allows local users to bypass authentication and modify firewall configurations via the (1) addPassthrough, (2) removePassthrough, (3) addEntry, (4) removeEntry, or (5) setEntries D-Bus API method. |
| In all Android releases from CAF using the Linux kernel, the Hypervisor API could be misused to bypass authentication. |
| Summer Baby Zoom Wifi Monitor & Internet Viewing System allows remote attackers to bypass authentication, related to the MySnapCam web service. |
| In Odoo 8.0, Odoo Community Edition 9.0 and 10.0, and Odoo Enterprise Edition 9.0 and 10.0, remote attackers can bypass authentication under certain circumstances because parameters containing 0x00 characters are truncated before reaching the database layer. This occurs because Psycopg 2.x before 2.6.3 is used. |
| JabberD 2.x (aka jabberd2) before 2.6.1 allows anyone to authenticate using SASL ANONYMOUS, even when the sasl.anonymous c2s.xml option is not enabled. |
| IBM BigFix Compliance (TEMA SUAv1 SCA SCM) uses an inadequate account lockout setting that could allow a remote attacker to brute force account credentials. IBM X-Force ID: 123672. |
| A Missing Authentication for Critical Function issue was discovered in Schneider Electric InduSoft Web Studio v8.0 SP2 or prior, and InTouch Machine Edition v8.0 SP2 or prior. InduSoft Web Studio provides the capability for an HMI client to trigger script execution on the server for the purposes of performing customized calculations or actions. A remote malicious entity could bypass the server authentication and trigger the execution of an arbitrary command. The command is executed under high privileges and could lead to a complete compromise of the server. |
| A Missing Authentication for Critical Function issue was discovered in OPW Fuel Management Systems SiteSentinel Integra 100, SiteSentinel Integra 500, and SiteSentinel iSite ATG consoles with the following software versions: older than V175, V175-V189, V191-V195, and V16Q3.1. An attacker may create an application user account to gain administrative privileges. |
| The Erlang otp TLS server answers with different TLS alerts to different error types in the RSA PKCS #1 1.5 padding. This allows an attacker to decrypt content or sign messages with the server's private key (this is a variation of the Bleichenbacher attack). |
| An issue was discovered in Veritas NetBackup 8.0 and earlier and NetBackup Appliance 3.0 and earlier. Unauthenticated CORBA interfaces permit inappropriate access. |