| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| Delta Electronics TPEditor, Versions 1.94 and prior. Multiple stack-based buffer overflow vulnerabilities may be exploited by processing specially crafted project files, which may allow an attacker to remotely execute arbitrary code. |
| 3S-Smart Software Solutions GmbH CODESYS V3 Library Manager, all versions prior to 3.5.16.0, allows the system to display active library content without checking its validity, which may allow the contents of manipulated libraries to be displayed or executed. The issue also exists for source libraries, but 3S-Smart Software Solutions GmbH strongly recommends distributing compiled libraries only. |
| The IEC870IP driver for AVEVA’s Vijeo Citect and Citect SCADA and Schneider Electric’s Power SCADA Operation has a buffer overflow vulnerability that could result in a server-side crash. |
| Delta Electronics TPEditor, Versions 1.94 and prior. Multiple heap-based buffer overflow vulnerabilities may be exploited by processing specially crafted project files, which may allow an attacker to remotely execute arbitrary code. |
| Philips IntelliVue WLAN, portable patient monitors, WLAN Version A, Firmware A.03.09, WLAN Version A, Firmware A.03.09, Part #: M8096-67501, WLAN Version B, Firmware A.01.09, Part #: N/A (Replaced by Version C) and WLAN Version B, Firmware A.01.09, Part #: N/A (Replaced by Version C). The product downloads source code or an executable from a remote location and executes the code without sufficiently verifying the origin and integrity of the code. |
| CODESYS V3 web server, all versions prior to 3.5.14.10, allows an attacker to send specially crafted http or https requests which may allow access to files outside the restricted working directory of the controller. |
| Philips IntelliVue WLAN, portable patient monitors, WLAN Version A, Firmware A.03.09, WLAN Version A, Firmware A.03.09, Part #: M8096-67501, WLAN Version B, Firmware A.01.09, Part #: N/A (Replaced by Version C) and WLAN Version B, Firmware A.01.09, Part #: N/A (Replaced by Version C). An attacker can use these credentials to login via ftp and upload a malicious firmware. |
| GE PACSystems RX3i CPE100/115: All versions prior to R9.85,CPE302/305/310/330/400/410: All versions prior to R9.90,CRU/320 All versions(End of Life) may allow an attacker sending specially manipulated packets to cause the module state to change to halt-mode, resulting in a denial-of-service condition. An operator must reboot the CPU module after removing battery or energy pack to recover from halt-mode. |
| An attacker could use a specially crafted project file to corrupt the memory and execute code under the privileges of the EZ PLC Editor Versions 1.8.41 and prior. |
| Multiple buffer overflow issues have been identified in Alpha5 Smart Loader: All versions prior to 4.2. An attacker could use specially crafted project files to overflow the buffer and execute code under the privileges of the application. |
| In OSIsoft PI Web API and prior, the affected product is vulnerable to a direct attack due to a cross-site request forgery protection setting that has not taken effect. |
| In Delta Industrial Automation DOPSoft, Version 4.00.06.15 and prior, processing a specially crafted project file may trigger a use-after-free vulnerability, which may allow information disclosure, remote code execution, or crash of the application. |
| In Delta Industrial Automation DOPSoft, Version 4.00.06.15 and prior, processing a specially crafted project file may trigger multiple out-of-bounds read vulnerabilities, which may allow information disclosure, remote code execution, or crash of the application. |
| mq_parse_http in mongoose.c in Mongoose 6.15 has a heap-based buffer over-read. |
| One Identity Cloud Access Manager 8.1.3 does not use HTTP Strict Transport Security (HSTS), which may allow man-in-the-middle (MITM) attacks. This issue is fixed in version 8.1.4. |
| One Identity Cloud Access Manager before 8.1.4 Hotfix 1 allows OTP bypass via vectors involving a man in the middle, the One Identity Defender product, and replacing a failed SAML response with a successful SAML response. |
| An issue was discovered on D-Link DIR-818LW devices with firmware 2.06betab01. There is a command injection in HNAP1 (exploitable with Authentication) via shell metacharacters in the Type field to SetWanSettings. |
| An issue was discovered on D-Link DIR-818LW devices with firmware 2.06betab01. There is a command injection in HNAP1 (exploitable with Authentication) via shell metacharacters in the MTU field to SetWanSettings. |
| Western Digital SSD Dashboard before 2.5.1.0 and SanDisk SSD Dashboard before 2.5.1.0 have Incorrect Access Control. The “generate reports” archive is protected with a hard-coded password. An application update that addresses the protection of archive encryption is available. |
| An issue was discovered in the ROS communications-related packages (aka ros_comm or ros-melodic-ros-comm) through 1.14.3. ROS_ASSERT_MSG only works when ROS_ASSERT_ENABLED is defined. This leads to a problem in the remove() function in clients/roscpp/src/libros/spinner.cpp. When ROS_ASSERT_ENABLED is not defined, the iterator loop will run out of the scope of the array, and cause denial of service for other components (that depend on the communication-related functions of this package). NOTE: The reporter of this issue now believes it was a false alarm. |