| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| In resetSettingsLocked of SettingsProvider.java, there is a possible lockscreen bypass due to a permissions bypass. This could lead to local escalation of privilege with no additional execution privileges needed. User interaction is not needed for exploitation. |
| D-Link DIR-882 1.10B02 and 1.20B06 is vulnerable to Buffer Overflow via webGetVarString. |
| D-Link DIR-882 1.10B02 and 1.20B06 is vulnerable to Buffer Overflow. |
| D-Link DIR-882 1.10B02 and1.20B06 is vulnerable to Buffer Overflow via the websRedirect function. |
| D-Link DIR-878 1.02B05 is vulnerable to Incorrect Access Control. |
| D-Link DIR878 1.02B04 and 1.02B05 are vulnerable to Buffer Overflow. |
| Tenda AC18 V15.03.05.19 is vulnerable to Buffer Overflow via function R7WebsSecurityHandler. |
| Tenda AC18 V15.03.05.19 is vulnerable to Buffer Overflow via function form_fast_setting_wifi_set. |
| Tenda AC15 V15.03.05.18 is vulnerable to Buffer Overflow via function formSetVirtualSer. |
| Online Leave Management System v1.0 was discovered to contain a SQL injection vulnerability via the component /admin/?page=user/manage_user&id=. |
| A cross-site scripting (XSS) vulnerability in Beekeeper Studio v3.6.6 allows attackers to execute arbitrary web scripts or HTML via a crafted payload injected into the error modal container. |
| Sourcecodester Password Storage Application in PHP/OOP and MySQL 1.0 was discovered to contain multiple cross-site scripting (XSS) vulnerabilities via the Name, Username, Description and Site Feature parameters. |
| A vulnerability has been identified in syngo Dynamics (All versions < VA40G HF01). syngo Dynamics application server hosts a web service using an operation with improper write access control that could allow to write data in any folder accessible to the account assigned to the website’s application pool. |
| A vulnerability has been identified in syngo Dynamics (All versions < VA40G HF01). syngo Dynamics application server hosts a web service using an operation with improper write access control that could allow to write data in any folder accessible to the account assigned to the website’s application pool. |
| A vulnerability has been identified in syngo Dynamics (All versions < VA40G HF01). syngo Dynamics application server hosts a web service using an operation with improper read access control that could allow files to be retrieved from any folder accessible to the account assigned to the website’s application pool. |
| Backdrop CMS version 1.23.0 was discovered to contain a stored cross-site scripting (XSS) vulnerability via Post content. |
| Phpgurukul Blood Donor Management System 1.0 allows Cross Site Scripting via Add Blood Group Name Feature. |
| Cross-site Scripting (XSS) - Generic in GitHub repository librenms/librenms prior to 22.10.0. |
| IOBit IOTransfer V4 is vulnerable to Unquoted Service Path. |
| DLINK - DSL-224 Post-auth RCE.
DLINK router version 3.0.8 has an interface where you can configure NTP servers (Network Time Protocol) via jsonrpc API.
It is possible to inject a command through this interface that will run with ROOT permissions on the router.
|