| In JetBrains IntelliJ IDEA before 2021.3.1, local code execution via RLO (Right-to-Left Override) characters was possible. |
| In JetBrains IntelliJ IDEA before 2021.2.4, local code execution (without permission from a user) upon opening a project was possible. |
| In JetBrains TeamCity before 2021.2.1, URL injection leading to CSRF was possible. |
| In JetBrains TeamCity before 2021.2.1, editing a user account to change its password didn't terminate sessions of the edited user. |
| JetBrains TeamCity before 2021.2 was vulnerable to a Time-of-check/Time-of-use (TOCTOU) race-condition attack in agent registration via XML-RPC. |
| In JetBrains Hub before 2021.1.13890, integration with JetBrains Account exposed an API key with excessive permissions. |
| A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that could cause Denial of Service against the Geo SCADA server when receiving a malformed HTTP request. Affected Product: ClearSCADA (All Versions), EcoStruxure Geo SCADA Expert 2019 (All Versions), EcoStruxure Geo SCADA Expert 2020 (All Versions) |
| A CWE-326: Inadequate Encryption Strength vulnerability exists that could cause non-encrypted communication with the server when outdated versions of the ViewX client are used. Affected Product: ClearSCADA (All Versions), EcoStruxure Geo SCADA Expert 2019 (All Versions), EcoStruxure Geo SCADA Expert 2020 (All Versions) |
| A CWE-862: Missing Authorization vulnerability exists that could cause information exposure when an attacker sends a specific message. Affected Product: Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior) |
| A CWE-665: Improper Initialization vulnerability exists that could cause information exposure when an attacker sends a specially crafted message. Affected Product: Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior) |
| A CWE-125: Out-of-bounds Read vulnerability exists that could cause denial of service when an attacker repeatedly sends a specially crafted message. Affected Product: Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior) |
| A CWE-125: Out-of-bounds Read vulnerability exists that could cause memory leaks potentially resulting in denial of service when an attacker repeatedly sends a specially crafted message. Affected Product: Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior) |
| Improper input validation vulnerability in pfSense CE and pfSense Plus (pfSense CE software versions prior to 2.6.0 and pfSense Plus software versions prior to 22.01) allows a remote attacker with the privilege to change OpenVPN client or server settings to execute an arbitrary command. |
| Use of a Broken or Risky Cryptographic Algorithm vulnerability in Air Conditioning System G-150AD Ver. 3.21 and prior, Air Conditioning System AG-150A-A Ver. 3.21 and prior, Air Conditioning System AG-150A-J Ver. 3.21 and prior, Air Conditioning System GB-50AD Ver. 3.21 and prior, Air Conditioning System GB-50ADA-A Ver. 3.21 and prior, Air Conditioning System GB-50ADA-J Ver. 3.21 and prior, Air Conditioning System EB-50GU-A Ver. 7.10 and prior, Air Conditioning System EB-50GU-J Ver. 7.10 and prior, Air Conditioning System AE-200J Ver. 7.97 and prior, Air Conditioning System AE-200A Ver. 7.97 and prior, Air Conditioning System AE-200E Ver. 7.97 and prior, Air Conditioning System AE-50J Ver. 7.97 and prior, Air Conditioning System AE-50A Ver. 7.97 and prior, Air Conditioning System AE-50E Ver. 7.97 and prior, Air Conditioning System EW-50J Ver. 7.97 and prior, Air Conditioning System EW-50A Ver. 7.97 and prior, Air Conditioning System EW-50E Ver. 7.97 and prior, Air Conditioning System TE-200A Ver. 7.97 and prior, Air Conditioning System TE-50A Ver. 7.97 and prior and Air Conditioning System TW-50A Ver. 7.97 and prior allows a remote unauthenticated attacker to cause a disclosure of encrypted message of the air conditioning systems by sniffing encrypted communications. |
| Okta Advanced Server Access Client for Windows prior to version 1.57.0 was found to be vulnerable to command injection via a specially crafted URL. |
| A regular expression used in Apache MXNet (incubating) is vulnerable to a potential denial-of-service by excessive resource consumption. The bug could be exploited when loading a model in Apache MXNet that has a specially crafted operator name that would cause the regular expression evaluation to use excessive resources to attempt a match. This issue affects Apache MXNet versions prior to 1.9.1. |
| Certain HP Print devices may be vulnerable to potential information disclosure, denial of service, or remote code execution. |
| A vulnerability has been identified in Teamcenter V12.4 (All versions < V12.4.0.13), Teamcenter V13.0 (All versions < V13.0.0.9), Teamcenter V13.1 (All versions), Teamcenter V13.2 (All versions < V13.2.0.8), Teamcenter V13.3 (All versions < V13.3.0.3), Teamcenter V14.0 (All versions < V14.0.0.2). The tcserver.exe binary in affected applications is vulnerable to a stack overflow condition during the parsing of user input that may lead the binary to crash. |
| Hessian serialization is a network protocol that supports object-based transmission. Apache Cayenne's optional Remote Object Persistence (ROP) feature is a web services-based technology that provides object persistence and query functionality to 'remote' applications. In Apache Cayenne 4.1 and earlier, running on non-current patch versions of Java, an attacker with client access to Cayenne ROP can transmit a malicious payload to any vulnerable third-party dependency on the server. This can result in arbitrary code execution. |
| In Apache Airflow, prior to version 2.2.4, some example DAGs did not properly sanitize user-provided params, making them susceptible to OS Command Injection from the web UI. |