| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| A path traversal vulnerability [CWE-22] in FortiAP-U CLI 6.2.0 through 6.2.3, 6.0.0 through 6.0.4, 5.4.0 through 5.4.6 may allow an admin user to delete and access unauthorized files and data via specifically crafted CLI commands. |
| An improper privilege management vulnerability [CWE-269] in Fortinet FortiSOAR before 7.2.1 allows a GUI user who has already found a way to modify system files (via another, unrelated and hypothetical exploit) to execute arbitrary Python commands as root. |
| In WebKitGTK through 2.36.0 (and WPE WebKit), there is a heap-based buffer overflow in WebCore::TextureMapperLayer::setContentsLayer in WebCore/platform/graphics/texmap/TextureMapperLayer.cpp. |
| In OpenCTI through 5.2.4, a broken access control vulnerability has been identified in the profile endpoint. An attacker can abuse the identified vulnerability in order to arbitrarily change their registered e-mail address as well as their API key, even though such action is not possible through the interface, legitimately. |
| Agoo before 2.14.3 does not reject GraphQL fragment spreads that form cycles, leading to an application crash. NOTE: the vendor has disputed this on the grounds that it is not the server's responsibility to "enforce all the various ways a developer could write code with logic errors. |
| Horde Groupware Webmail Edition through 5.2.22 allows a reflection injection attack through which an attacker can instantiate a driver class. This then leads to arbitrary deserialization of PHP objects. |
| pyscriptjs (aka PyScript Demonstrator) in PyScript through 2022-05-04 allows a remote user to read Python source code. |
| /SecurityManagement/html/createuser.jsf in Nokia NetAct 22 allows CSRF. A remote attacker is able to create users with arbitrary privileges, even administrative privileges. The application (even if it implements a CSRF token for the random GET request) does not ever verify a CSRF token. With a little help of social engineering/phishing (such as sending a link via email or chat), an attacker may trick the users of a web application into executing actions of the attacker's choosing. If the victim is a normal user, a successful CSRF attack can force the user to perform state changing requests like transferring funds, changing their email address, and so forth. If the victim is an administrative account, CSRF can compromise the entire web application. |
| An issue was discovered in Stormshield Network Security (SNS) 4.3.x before 4.3.8. The event logging of the ASQ sofbus lacbus plugin triggers the dereferencing of a NULL pointer, leading to a crash of SNS. An attacker could exploit this vulnerability via forged sofbus lacbus traffic to cause a firmware crash. |
| The Motorola MOSCAD and ACE line of RTUs through 2022-05-02 omit an authentication requirement. They feature IP Gateway modules which allow for interfacing between Motorola Data Link Communication (MDLC) networks (potentially over a variety of serial, RF and/or Ethernet links) and TCP/IP networks. Communication with RTUs behind the gateway is done by means of the proprietary IPGW protocol (5001/TCP). This protocol does not have any authentication features, allowing any attacker capable of communicating with the port in question to invoke (a subset of) desired functionality. |
| The Motorola MOSCAD Toolbox software through 2022-05-02 relies on a cleartext password. It utilizes an MDLC driver to communicate with MOSCAD/ACE RTUs for engineering purposes. Access to these communications is protected by a password stored in cleartext in the wmdlcdrv.ini driver configuration file. In addition, this password is used for access control to MOSCAD/STS projects protected with the Legacy Password feature. In this case, an insecure CRC of the password is present in the project file: this CRC is validated against the password in the driver configuration file. |
| The Motorola ACE1000 RTU through 2022-05-02 mishandles firmware integrity. It utilizes either the STS software suite or ACE1000 Easy Configurator for performing firmware updates. In case of the Easy Configurator, firmware updates are performed through access to the Web UI where file system, kernel, package, bundle, or application images can be installed. Firmware updates for the Front End Processor (FEP) module are performed via access to the SSH interface (22/TCP), where a .hex file image is transferred and a bootloader script invoked. File system, kernel, package, and bundle updates are supplied as RPM (RPM Package Manager) files while FEP updates are supplied as S-rec files. In all cases, firmware images were found to have no authentication (in the form of firmware signing) and only relied on insecure checksums for regular integrity checks. |
| Motorola ACE1000 RTUs through 2022-05-02 mishandle application integrity. They allow for custom application installation via either STS software, the C toolkit, or the ACE1000 Easy Configurator. In the case of the Easy Configurator, application images (as PLX/DAT/APP/CRC files) are uploaded via the Web UI. In case of the C toolkit, they are transferred and installed using SFTP/SSH. In each case, application images were found to have no authentication (in the form of firmware signing) and only relied on insecure checksums for regular integrity checks. |
| The Emerson ControlWave 'Next Generation' RTUs through 2022-05-02 mishandle firmware integrity. They utilize the BSAP-IP protocol to transmit firmware updates. Firmware updates are supplied as CAB archive files containing a binary firmware image. In all cases, firmware images were found to have no authentication (in the form of firmware signing) and only relied on insecure checksums for regular integrity checks. |
| Emerson DeltaV Distributed Control System (DCS) has insufficient verification of firmware integrity (an inadequate checksum approach, and no signature). This affects versions before 14.3 of DeltaV M-series, DeltaV S-series, DeltaV P-series, DeltaV SIS, and DeltaV CIOC/EIOC/WIOC IO cards. |
| Honeywell Alerton Ascent Control Module (ACM) through 2022-05-04 allows unauthenticated programming writes from remote users. This enables code to be store on the controller and then run without verification. A user with malicious intent can send a crafted packet to change and/or stop the program without the knowledge of other users, altering the controller's function. After the programming change, the program needs to be overwritten in order for the controller to restore its original operational function. |
| Honeywell Alerton Visual Logic through 2022-05-04 allows unauthenticated programming writes from remote users. This enables code to be stored on the controller and then run without verification. A user with malicious intent can send a crafted packet to change and/or stop the program without the knowledge of other users, altering the controller's function. After the programming change, the program needs to be overwritten in order for the controller to restore its original operational function. |
| An argument injection vulnerability in the browser-based authentication component of the Magnitude Simba Amazon Redshift JDBC Driver 1.2.40 through 1.2.55 may allow a local user to execute code. NOTE: this is different from CVE-2022-29972. |
| An argument injection vulnerability in the browser-based authentication component of the Magnitude Simba Amazon Athena JDBC Driver 2.0.25 through 2.0.28 may allow a local user to execute code. NOTE: this is different from CVE-2022-29971. |
| A CWE-287: Improper Authentication vulnerability exists that could allow an attacker to take over the admin account when an attacker hijacks a session. Affected Products: Wiser Smart, EER21000 & EER21001 (V4.5 and prior) |