Search Results (9570 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2021-22752 1 Schneider-electric 1 Interactive Graphical Scada System 2024-11-21 7.8 High
A CWE-787: Out-of-bounds write vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that could result in loss of data or remote code execution due to missing size checks, when a malicious WSP (Workspace) file is being parsed by IGSS Definition.
CVE-2021-22750 1 Schneider-electric 1 Interactive Graphical Scada System 2024-11-21 7.8 High
A CWE-787: Out-of-bounds write vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21041 and prior that could result in loss of data or remote code execution due to missing length checks, when a malicious CGF file is imported to IGSS Definition.
CVE-2021-22748 1 Schneider-electric 1 C-bus Toolkit 2024-11-21 8.8 High
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists that could allow a remote code execution when a file is saved. Affected Product: C-Bus Toolkit (V1.15.9 and prior), C-Gate Server (V2.11.7 and prior)
CVE-2021-22735 1 Schneider-electric 4 Homelynk, Homelynk Firmware, Spacelynk and 1 more 2024-11-21 7.2 High
Improper Verification of Cryptographic Signature vulnerability exists inhomeLYnk (Wiser For KNX) and spaceLYnk V2.60 and prior which could allow remote code execution when unauthorized code is copied to the device.
CVE-2021-22734 1 Schneider-electric 4 Homelynk, Homelynk Firmware, Spacelynk and 1 more 2024-11-21 7.2 High
Improper Verification of Cryptographic Signature vulnerability exists in homeLYnk (Wiser For KNX) and spaceLYnk V2.60 and prior which could cause remote code execution when an attacker loads unauthorized code.
CVE-2021-22720 1 Schneider-electric 1 C-bus Toolkit 2024-11-21 7.2 High
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists in C-Bus Toolkit (V1.15.7 and prior) that could allow a remote code execution when restoring a project.
CVE-2021-22719 1 Schneider-electric 1 C-bus Toolkit 2024-11-21 8.8 High
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists in C-Bus Toolkit (V1.15.7 and prior) that could allow a remote code execution when a file is uploaded.
CVE-2021-22718 1 Schneider-electric 1 C-bus Toolkit 2024-11-21 7.8 High
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists in C-Bus Toolkit (V1.15.7 and prior) that could allow a remote code execution when restoring project files.
CVE-2021-22717 1 Schneider-electric 1 C-bus Toolkit 2024-11-21 8.8 High
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists in C-Bus Toolkit (V1.15.7 and prior) that could allow a remote code execution when processing config files.
CVE-2021-22716 1 Schneider-electric 1 C-bus Toolkit 2024-11-21 7.8 High
A CWE-732: Incorrect Permission Assignment for Critical Resource vulnerability exists that could allow remote code execution when an unprivileged user modifies a file. Affected Product: C-Bus Toolkit (V1.15.9 and prior)
CVE-2021-22714 1 Schneider-electric 6 Powerlogic Ion7400, Powerlogic Ion7400 Firmware, Powerlogic Ion9000 and 3 more 2024-11-21 9.8 Critical
A CWE-119:Improper restriction of operations within the bounds of a memory buffer vulnerability exists in PowerLogic ION7400, PM8000 and ION9000 (All versions prior to V3.0.0), which could cause the meter to reboot or allow for remote code execution.
CVE-2021-22710 1 Schneider-electric 1 Interactive Graphical Scada System 2024-11-21 7.8 High
A CWE-119:Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists in Interactive Graphical SCADA System (IGSS) Definition (Def.exe) V15.0.0.21041 and prior, which could cause remote code execution when malicious CGF (Configuration Group File) file is imported to IGSS Definition.
CVE-2021-22709 1 Schneider-electric 1 Interactive Graphical Scada System 2024-11-21 7.8 High
A CWE-119:Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists in Interactive Graphical SCADA System (IGSS) Definition (Def.exe) V15.0.0.21041 and prior, which could result in loss of data or remote code execution when malicious CGF (Configuration Group File) file is imported to IGSS Definition.
CVE-2021-22698 1 Schneider-electric 1 Ecostruxure Power Build - Rapsody 2024-11-21 7.8 High
A CWE-434: Unrestricted Upload of File with Dangerous Type vulnerability exists in the EcoStruxure Power Build - Rapsody software (V2.1.13 and prior) that could allow a stack-based buffer overflow to occur which could result in remote code execution when a malicious SSD file is uploaded and improperly parsed.
CVE-2021-22697 1 Schneider-electric 1 Ecostruxure Power Build - Rapsody 2024-11-21 7.8 High
A CWE-434: Unrestricted Upload of File with Dangerous Type vulnerability exists in the EcoStruxure Power Build - Rapsody software (V2.1.13 and prior) that could allow a use-after-free condition which could result in remote code execution when a malicious SSD file is uploaded and improperly parsed.
CVE-2021-22191 3 Debian, Oracle, Wireshark 3 Debian Linux, Zfs Storage Appliance, Wireshark 2024-11-21 6.3 Medium
Improper URL handling in Wireshark 3.4.0 to 3.4.3 and 3.2.0 to 3.2.11 could allow remote code execution via via packet injection or crafted capture file.
CVE-2021-22153 1 Blackberry 1 Unified Endpoint Management 2024-11-21 7.3 High
A Remote Code Execution vulnerability in the Management Console component of BlackBerry UEM version(s) 12.13.1 QF2 and earlier and 12.12.1a QF6 and earlier could allow an attacker to potentially cause the spreadsheet application to run commands on the victim’s local machine with the authority of the user.
CVE-2021-21984 1 Vmware 1 Vrealize Business For Cloud 2024-11-21 9.8 Critical
VMware vRealize Business for Cloud 7.x prior to 7.6.0 contains a remote code execution vulnerability due to an unauthorised end point. A malicious actor with network access may exploit this issue causing unauthorised remote code execution on vRealize Business for Cloud Virtual Appliance.
CVE-2021-21978 1 Vmware 1 View Planner 2024-11-21 9.8 Critical
VMware View Planner 4.x prior to 4.6 Security Patch 1 contains a remote code execution vulnerability. Improper input validation and lack of authorization leading to arbitrary file upload in logupload web application. An unauthorized attacker with network access to View Planner Harness could upload and execute a specially crafted file leading to remote code execution within the logupload container.
CVE-2021-21976 1 Vmware 1 Vsphere Replication 2024-11-21 7.2 High
vSphere Replication 8.3.x prior to 8.3.1.2, 8.2.x prior to 8.2.1.1, 8.1.x prior to 8.1.2.3 and 6.5.x prior to 6.5.1.5 contain a post-authentication command injection vulnerability which may allow an authenticated admin user to perform a remote code execution.