| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| This vulnerability exists in Philips lighting devices due to storage of Wi-Fi credentials in plain text within the device firmware. An attacker with physical access could exploit this by extracting the firmware and analyzing the binary data to obtain the plaintext Wi-Fi credentials stored on the vulnerable device.
Successful exploitation of this vulnerability could allow an attacker to gain unauthorized access to the Wi-Fi network to which vulnerable device is connected. |
| A vulnerability has been found in Coinomi up to 1.7.6. This issue affects some unknown processing. Such manipulation leads to cleartext transmission of sensitive information. The attack can be launched remotely. This attack is characterized by high complexity. The exploitability is assessed as difficult. The exploit has been disclosed to the public and may be used. The vendor replied with: "(...) there isn't any security implication associated with your findings." |
| Unencrypted storage in the database in Two App Studio Journey v5.5.9 for iOS allows local attackers to extract sensitive data via direct access to the app’s filesystem. |
| Insufficiently Protected Credentials in the Mail Server Configuration in GoPhish v0.12.1 allows an attacker to access cleartext passwords for the configured IMAP and SMTP servers. |
| A vulnerability was found in Ruijie EG306MG 3.0(1)B11P309. It has been rated as problematic. This issue affects some unknown processing of the file /etc/strongswan.conf of the component strongSwan. The manipulation of the argument i_dont_care_about_security_and_use_aggressive_mode_psk leads to missing encryption of sensitive data. The attack may be initiated remotely. The complexity of an attack is rather high. The exploitation is known to be difficult. The vendor was contacted early about this disclosure but did not respond in any way. |
| Medtronic MyCareLink Patient Monitor uses an unencrypted filesystem on internal storage, which allows an attacker with physical access to read and modify files.
This issue affects MyCareLink Patient Monitor models 24950 and 24952: before June 25, 2025 |
| This vulnerability exists in Digisol DG-GR6821AC Router due to cleartext transmission of credentials in its web management interface. A remote attacker could exploit this vulnerability by intercepting the network traffic and capturing cleartext credentials.
Successful exploitation of this vulnerability could allow the attacker to gain unauthorized access to the targeted device. |
| An flaw was found in the OpenStack Platform (RHOSP) director, a toolset for installing and managing a complete RHOSP environment. Plaintext passwords may be stored in log files, which can expose sensitive information to anyone with access to the logs. |
| The YoSmart YoLink Smart Hub firmware 0382 is unencrypted, and data extracted from it can be used to determine network access credentials. |
| In Unify CP IP Phone firmware 1.10.4.3, files are not encrypted and contain sensitive information such as the root password hash. |
| A Credential Exposure Vulnerability exists in the above-mentioned product and version. The vulnerability is due to using HTTP resulting in credentials being sent in clear text. |
| DuraComm SPM-500 DP-10iN-100-MU
transmits sensitive data without encryption over a channel that could be intercepted by attackers. |
| The Temporal api-go library prior to version 1.44.1 did not send `update response` information to Data Converter when the proxy package within the api-go module was used in a gRPC proxy prior to transmission. This resulted in information contained within the `update response` field not having Data Converter transformations (e.g. encryption) applied. This is an issue only when using the UpdateWorkflowExecution APIs (released on 13th January 2025) with a proxy leveraging the api-go library before version 1.44.1.
Other data fields were correctly sent to Data Converter. This issue does not impact the Data Converter server. Data was encrypted in transit. Temporal Cloud services are not impacted. |
| An issue was discovered on Marbella KR8s Dashcam FF 2.0.8 devices. When a new SD card is inserted into the dashcam, the existing password is written onto the SD card in cleartext automatically. An attacker with temporary access to the dashcam can switch the SD card to steal this password. |
| A vulnerability has been identified in POWER METER SICAM Q100 (7KG9501-0AA01-0AA1) (All versions >= V2.60 < V2.62), POWER METER SICAM Q100 (7KG9501-0AA01-2AA1) (All versions >= V2.60 < V2.62), POWER METER SICAM Q100 (7KG9501-0AA31-0AA1) (All versions >= V2.60 < V2.62), POWER METER SICAM Q100 (7KG9501-0AA31-2AA1) (All versions >= V2.60 < V2.62), POWER METER SICAM Q200 family (All versions >= V2.70 < V2.80). Affected devices export the password for the SMTP account as plain text in the Configuration File. This could allow an authenticated local attacker to extract it and use the configured SMTP service for arbitrary purposes. |
| Local Deep Research is an AI-powered research assistant for deep, iterative research. Versions 0.2.0 through 0.6.7 stored confidential information, including API keys, in a local SQLite database without encryption. This behavior was not clearly documented outside of the database architecture page. Users were not given the ability to configure the database location, allowing anyone with access to the container or host filesystem to retrieve sensitive data in plaintext by accessing the .db file. This is fixed in version 1.0.0. |
| ispdbservice.cpp in KDE Kmail before 6.2.0 allows man-in-the-middle attackers to trigger use of an attacker-controlled mail server because cleartext HTTP is used for a URL such as http://autoconfig.example.com or http://example.com/.well-known/autoconfig for retrieving the configuration. This is related to kmail-account-wizard. |
| The MOD3 command traffic between the monitoring application and the
inverter is transmitted in plaintext without encryption or obfuscation.
This vulnerability may allow an attacker with access to a local network
to intercept, manipulate, replay, or forge critical data, including
read/write operations for voltage, current, and power configuration,
operational status, alarms, telemetry, system reset, or inverter control
commands, potentially disrupting power generation or reconfiguring
inverter settings. |
| The device uses an unencrypted, proprietary protocol for communication. Through this protocol, configuration data is transmitted and device authentication is performed. An attacker can thereby intercept the authentication hash and use it to log into the device using a pass-the-hash attack. |
| A vulnerability has been found in youth-is-as-pale-as-poetry e-learning 1.0. Impacted is the function encryptSecret of the file e-learning-master\exam-api\src\main\java\com\yf\exam\ability\shiro\jwt\JwtUtils.java of the component JWT Token Handler. The manipulation leads to insufficiently random values. The attack can be initiated remotely. The complexity of an attack is rather high. The exploitability is considered difficult. The exploit has been disclosed to the public and may be used. |