| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| LS ELECTRIC XBC-DN32U with operating system version 01.80 transmits sensitive information in cleartext when communicating over its XGT protocol. This could allow an attacker to gain sensitive information such as user credentials.
|
|
The affected product DIAEnergie (versions prior to v1.9.03.001) contains improper authorization, which could allow an unauthorized user to bypass authorization and access privileged functionality.
|
| SAUTER Controls Nova 200–220 Series with firmware version 3.3-006 and
prior and BACnetstac version 4.2.1 and prior have only FTP and Telnet
available for device management. Any sensitive information communicated
through these protocols, such as credentials, is sent in cleartext. An
attacker could obtain sensitive information such as user credentials to
gain access to the system.
|
| An attacker with physical access to the affected Moxa UC Series devices can initiate a restart of the device and gain access to its BIOS. Command line options can then be altered, allowing the attacker to access the terminal. From the terminal, the attacker can modify the device’s authentication files to create a new user and gain full access to the system. |
| The Akuvox E11 web server backend library allows command injection in the device phone-book contacts functionality. This could allow an attacker to upload files with executable command instructions. |
| The Akuvox E11 libvoice library provides unauthenticated access to the camera capture for image and video. This could allow an attacker to view and record image and video from the camera. |
| Akuvox E11 allows direct SIP calls. No access control is enforced by the SIP servers, which could allow an attacker to contact any device within Akuvox to call any other device. |
| The Akuvox E11 Media Access Control (MAC) address, a primary identifier, combined with the Akuvox E11 IP address, could allow an attacker to identify the device on the Akuvox cloud. |
| Akuvox E11 uses a weak encryption algorithm for stored passwords and uses a hard-coded password for decryption which could allow the encrypted passwords to be decrypted from the configuration file. |
| Akuvox E11 cloud login is performed through an unencrypted HTTP connection. An attacker could gain access to the Akuvox cloud and device if the MAC address of a device if known. |
|
GE Digital Proficy iFIX 2022, GE Digital Proficy iFIX v6.1, and GE Digital Proficy iFIX v6.5 are vulnerable to code injection, which may allow an attacker to insert malicious configuration files in the expected web server execution path and gain full control of the HMI software.
|
| Delta Electronics InfraSuite Device Master versions prior to 1.0.5 are affected by a deserialization vulnerability targeting the Device-gateway service, which could allow deserialization of requests prior to authentication, resulting in remote code execution. |
| Delta Electronics InfraSuite Device Master versions prior to 1.0.5 contain an improper access control vulnerability, which could allow an attacker to retrieve Gateway configuration files to obtain plaintext credentials. |
| Delta Electronics InfraSuite Device Master versions prior to 1.0.5 contains an improper access control vulnerability in which an attacker can use the Device-Gateway service and bypass authorization, which could result in privilege escalation. |
| In Delta Electronics InfraSuite Device Master versions prior to 1.0.5, an attacker could use Lua scripts, which could allow an attacker to remotely execute arbitrary code. |
| Delta Electronics InfraSuite Device Master versions prior to 1.0.5 are affected by a path traversal vulnerability, which could allow an attacker to read local files, disclose plaintext credentials, and escalate privileges. |
| In Delta Electronics InfraSuite Device Master versions prior to 1.0.5, an attacker could use URL decoding to retrieve system files, credentials, and bypass authentication resulting in privilege escalation. |
| Delta Electronics InfraSuite Device Master versions prior to 1.0.5 contain a command injection vulnerability that could allow an attacker to inject arbitrary commands, which could result in remote code execution. |
|
Delta Electronics InfraSuite Device Master versions prior to 1.0.5 are affected by a deserialization vulnerability targeting the Device-DataCollect service, which could allow deserialization of requests prior to authentication, resulting in remote code execution.
|
|
In Delta Electronics InfraSuite Device Master versions prior to 1.0.5, an attacker could set incorrect directory permissions, which could result in local privilege escalation.
|