Total
224 CVE
| CVE | Vendors | Products | Updated | CVSS v3.1 |
|---|---|---|---|---|
| CVE-2025-24288 | 1 Versa | 1 Director | 2025-06-23 | 9.8 Critical |
| The Versa Director software exposes a number of services by default and allow attackers an easy foothold due to default credentials and multiple accounts (most with sudo access) that utilize the same default credentials. By default, Versa director exposes ssh and postgres to the internet, alongside a host of other services. Versa Networks is not aware of any reported instance where this vulnerability was exploited. Proof of concept for this vulnerability has been disclosed by third party security researchers. Workarounds or Mitigation: Versa recommends the following security controls: 1) Change default passwords to complex passwords 2) Passwords must be complex with at least 8 characters that comprise of upper case, and lower case alphabets, as well as at at least one digit, and one special character 3) Passwords must be changed at least every 90 days 4) Password change history is checked to ensure that the at least the last 5 passwords must be used when changing password. 5) Review and audit logs for all authentication attempts to check for unauthorized/suspicious login attempts and enforce remediation steps. | ||||
| CVE-2025-46599 | 1 K3s | 1 K3s | 2025-06-23 | 6.8 Medium |
| CNCF K3s 1.32 before 1.32.4-rc1+k3s1 has a Kubernetes kubelet configuration change with the unintended consequence that, in some situations, ReadOnlyPort is set to 10255. For example, the default behavior of a K3s online installation might allow unauthenticated access to this port, exposing credentials. | ||||
| CVE-2024-22207 | 1 Smartbear | 1 Swagger Ui | 2025-06-17 | 5.3 Medium |
| fastify-swagger-ui is a Fastify plugin for serving Swagger UI. Prior to 2.1.0, the default configuration of `@fastify/swagger-ui` without `baseDir` set will lead to all files in the module's directory being exposed via http routes served by the module. The vulnerability is fixed in v2.1.0. Setting the `baseDir` option can also work around this vulnerability. | ||||
| CVE-2025-47945 | 1 Donetick | 1 Donetick | 2025-06-12 | 9.1 Critical |
| Donetick an open-source app for managing tasks and chores. Prior to version 0.1.44, the application uses JSON Web Tokens (JWT) for authentication, but the signing secret has a weak default value. While the responsibility is left to the system administrator to change it, this approach is inadequate. The vulnerability is proven by existence of the issue in the live version as well. This issue can result in full account takeover of any user. Version 0.1.44 contains a patch. | ||||
| CVE-2025-41438 | 2025-05-30 | 9.8 Critical | ||
| The CS5000 Fire Panel is vulnerable due to a default account that exists on the panel. Even though it is possible to change this by SSHing into the device, it has remained unchanged on every installed system observed. This account is not root but holds high-level permissions that could severely impact the device's operation if exploited. | ||||
| CVE-2025-31930 | 2025-05-13 | 8.8 High | ||
| A vulnerability has been identified in IEC 1Ph 7.4kW Child socket (8EM1310-2EH04-0GA0) (All versions < V2.135), IEC 1Ph 7.4kW Child socket/ shutter (8EM1310-2EN04-0GA0) (All versions < V2.135), IEC 1Ph 7.4kW Parent cable 7m (8EM1310-2EJ04-3GA1) (All versions < V2.135), IEC 1Ph 7.4kW Parent cable 7m incl. SIM (8EM1310-2EJ04-3GA2) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket (8EM1310-2EH04-3GA1) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket incl. SIM (8EM1310-2EH04-3GA2) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket/ shutter (8EM1310-2EN04-3GA1) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket/ shutter SIM (8EM1310-2EN04-3GA2) (All versions < V2.135), IEC 3Ph 22kW Child cable 7m (8EM1310-3EJ04-0GA0) (All versions < V2.135), IEC 3Ph 22kW Child socket (8EM1310-3EH04-0GA0) (All versions < V2.135), IEC 3Ph 22kW Child socket/ shutter (8EM1310-3EN04-0GA0) (All versions < V2.135), IEC 3Ph 22kW Parent cable 7m (8EM1310-3EJ04-3GA1) (All versions < V2.135), IEC 3Ph 22kW Parent cable 7m incl. SIM (8EM1310-3EJ04-3GA2) (All versions < V2.135), IEC 3Ph 22kW Parent socket (8EM1310-3EH04-3GA1) (All versions < V2.135), IEC 3Ph 22kW Parent socket incl. SIM (8EM1310-3EH04-3GA2) (All versions < V2.135), IEC 3Ph 22kW Parent socket/ shutter (8EM1310-3EN04-3GA1) (All versions < V2.135), IEC 3Ph 22kW Parent socket/ shutter SIM (8EM1310-3EN04-3GA2) (All versions < V2.135), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA0) (All versions < V2.135), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA1) (All versions < V2.135), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA2) (All versions < V2.135), IEC ERK 3Ph 22 kW Child socket (8EM1310-3FH04-0GA0) (All versions < V2.135), IEC ERK 3Ph 22 kW Parent socket (8EM1310-3FH04-3GA1) (All versions < V2.135), IEC ERK 3Ph 22 kW Parent socket incl. SI (8EM1310-3FH04-3GA2) (All versions < V2.135), UL Commercial Cellular 48A NTEP (8EM1310-5HF14-1GA2) (All versions < V2.135), UL Commercial Child 40A w/ 15118 HW (8EM1310-4CF14-0GA0) (All versions < V2.135), UL Commercial Child 48A BA Compliant (8EM1315-5CG14-0GA0) (All versions < V2.135), UL Commercial Child 48A w/ 15118 HW (8EM1310-5CF14-0GA0) (All versions < V2.135), UL Commercial Parent 40A with Simcard (8EM1310-4CF14-1GA2) (All versions < V2.135), UL Commercial Parent 48A (USPS) (8EM1317-5CG14-1GA2) (All versions < V2.135), UL Commercial Parent 48A BA Compliant (8EM1315-5CG14-1GA2) (All versions < V2.135), UL Commercial Parent 48A with Simcard BA (8EM1310-5CF14-1GA2) (All versions < V2.135), UL Commercial Parent 48A, 15118, 25ft (8EM1310-5CG14-1GA1) (All versions < V2.135), UL Commercial Parent 48A, 15118, 25ft (8EM1314-5CG14-2FA2) (All versions < V2.135), UL Commercial Parent 48A, 15118, 25ft (8EM1315-5HG14-1GA2) (All versions < V2.135), UL Commercial Parent 48A,15118 25ft Sim (8EM1310-5CG14-1GA2) (All versions < V2.135), VersiCharge Blue™ 80A AC Cellular (8EM1315-7BG16-1FH2) (All versions < V2.135). Affected devices contain Modbus service enabled by default. This could allow an attacker connected to the same network to remotely control the EV charger. | ||||
| CVE-2021-47343 | 1 Linux | 1 Linux Kernel | 2025-05-12 | 5.5 Medium |
| In the Linux kernel, the following vulnerability has been resolved: dm btree remove: assign new_root only when removal succeeds remove_raw() in dm_btree_remove() may fail due to IO read error (e.g. read the content of origin block fails during shadowing), and the value of shadow_spine::root is uninitialized, but the uninitialized value is still assign to new_root in the end of dm_btree_remove(). For dm-thin, the value of pmd->details_root or pmd->root will become an uninitialized value, so if trying to read details_info tree again out-of-bound memory may occur as showed below: general protection fault, probably for non-canonical address 0x3fdcb14c8d7520 CPU: 4 PID: 515 Comm: dmsetup Not tainted 5.13.0-rc6 Hardware name: QEMU Standard PC RIP: 0010:metadata_ll_load_ie+0x14/0x30 Call Trace: sm_metadata_count_is_more_than_one+0xb9/0xe0 dm_tm_shadow_block+0x52/0x1c0 shadow_step+0x59/0xf0 remove_raw+0xb2/0x170 dm_btree_remove+0xf4/0x1c0 dm_pool_delete_thin_device+0xc3/0x140 pool_message+0x218/0x2b0 target_message+0x251/0x290 ctl_ioctl+0x1c4/0x4d0 dm_ctl_ioctl+0xe/0x20 __x64_sys_ioctl+0x7b/0xb0 do_syscall_64+0x40/0xb0 entry_SYSCALL_64_after_hwframe+0x44/0xae Fixing it by only assign new_root when removal succeeds | ||||
| CVE-2024-22388 | 1 Hidglobal | 16 Iclass Se Cp1000 Encoder, Iclass Se Cp1000 Encoder Firmware, Iclass Se Processors and 13 more | 2025-05-07 | 5.9 Medium |
| Certain configuration available in the communication channel for encoders could expose sensitive data when reader configuration cards are programmed. This data could include credential and device administration keys. | ||||
| CVE-2021-33130 | 1 Intel | 2 Realsense Id F450, Realsense Id F450 Firmware | 2025-05-05 | 4.6 Medium |
| Insecure default variable initialization of Intel(R) RealSense(TM) ID Solution F450 before version 2.6.0.74 may allow an unauthenticated user to potentially enable information disclosure via physical access. | ||||
| CVE-2025-43015 | 1 Jetbrains | 1 Rubymine | 2025-04-25 | 8.3 High |
| In JetBrains RubyMine before 2025.1 remote Interpreter overwrote ports to listen on all interfaces | ||||
| CVE-2022-3262 | 1 Redhat | 1 Openshift | 2025-04-23 | 8.1 High |
| A flaw was found in Openshift. A pod with a DNSPolicy of "ClusterFirst" may incorrectly resolve the hostname based on a service provided. This flaw allows an attacker to supply an incorrect name with the DNS search policy, affecting confidentiality and availability. | ||||
| CVE-2022-46831 | 1 Jetbrains | 1 Teamcity | 2025-04-22 | 6.6 Medium |
| In JetBrains TeamCity between 2022.10 and 2022.10.1 connecting to AWS using the "Default Credential Provider Chain" allowed TeamCity project administrators to access AWS resources normally limited to TeamCity system administrators. | ||||
| CVE-2022-20466 | 1 Google | 1 Android | 2025-04-22 | 5.5 Medium |
| In applyKeyguardFlags of NotificationShadeWindowControllerImpl.java, there is a possible way to observe the user's password on a secondary display due to an insecure default value. This could lead to local information disclosure with no additional execution privileges needed. User interaction is needed for exploitation.Product: AndroidVersions: Android-10 Android-11 Android-12 Android-12L Android-13Android ID: A-179725730 | ||||
| CVE-2025-1863 | 2025-04-21 | 9.8 Critical | ||
| Insecure default settings have been found in recorder products provided by Yokogawa Electric Corporation. The default setting of the authentication function is disabled on the affected products. Therefore, when connected to a network with default settings, anyone can access all functions related to settings and operations. As a result, an attacker can illegally manipulate and configure important data such as measured values and settings. This issue affects GX10 / GX20 / GP10 / GP20 Paperless Recorders: R5.04.01 or earlier; GM Data Acquisition System: R5.05.01 or earlier; DX1000 / DX2000 / DX1000N Paperless Recorders: R4.21 or earlier; FX1000 Paperless Recorders: R1.31 or earlier; μR10000 / μR20000 Chart Recorders: R1.51 or earlier; MW100 Data Acquisition Units: All versions; DX1000T / DX2000T Paperless Recorders: All versions; CX1000 / CX2000 Paperless Recorders: All versions. | ||||
| CVE-2022-24287 | 1 Siemens | 3 Simatic Pcs 7, Simatic Wincc, Simatic Wincc Runtime Professional | 2025-04-21 | 7.8 High |
| A vulnerability has been identified in SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP3 UC06), SIMATIC PCS 7 V9.1 (All versions < V9.1 SP1 UC01), SIMATIC WinCC Runtime Professional V16 and earlier (All versions), SIMATIC WinCC Runtime Professional V17 (All versions < V17 Upd4), SIMATIC WinCC V7.3 (All versions), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Update 21), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 8). A missing printer configuration on the host could allow an authenticated attacker to escape the WinCC Kiosk Mode. | ||||
| CVE-2017-6689 | 1 Cisco | 1 Elastic Services Controller | 2025-04-20 | N/A |
| A vulnerability in the ConfD CLI of Cisco Elastic Services Controllers could allow an authenticated, remote attacker to log in to an affected system as the admin user, aka an Insecure Default Administrator Credentials Vulnerability. More Information: CSCvc76661. Known Affected Releases: 2.2(9.76). | ||||
| CVE-2017-8218 | 1 Tp-link | 4 C2, C20i, C20i Firmware and 1 more | 2025-04-20 | N/A |
| vsftpd on TP-Link C2 and C20i devices through firmware 0.9.1 4.2 v0032.0 Build 160706 Rel.37961n has a backdoor admin account with the 1234 password, a backdoor guest account with the guest password, and a backdoor test account with the test password. | ||||
| CVE-2017-7964 | 1 Zyxel | 1 Wre6505 Firmware | 2025-04-20 | N/A |
| Zyxel WRE6505 devices have a default TELNET password of 1234 for the root and admin accounts, which makes it easier for remote attackers to conduct DNS hijacking attacks by reconfiguring the built-in dnshijacker process. | ||||
| CVE-2017-4971 | 1 Pivotal | 1 Spring Web Flow | 2025-04-20 | N/A |
| An issue was discovered in Pivotal Spring Web Flow through 2.4.4. Applications that do not change the value of the MvcViewFactoryCreator useSpringBinding property which is disabled by default (i.e., set to 'false') can be vulnerable to malicious EL expressions in view states that process form submissions but do not have a sub-element to declare explicit data binding property mappings. | ||||
| CVE-2017-5491 | 1 Wordpress | 1 Wordpress | 2025-04-20 | N/A |
| wp-mail.php in WordPress before 4.7.1 might allow remote attackers to bypass intended posting restrictions via a spoofed mail server with the mail.example.com name. | ||||