Search Results (1390 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2022-50691 1 Minidvblinux 1 Minidvblinux 2026-01-12 9.8 Critical
MiniDVBLinux 5.4 contains a remote command execution vulnerability that allows unauthenticated attackers to execute arbitrary commands as root through the 'command' GET parameter. Attackers can exploit the /tpl/commands.sh endpoint by sending malicious command values to gain root-level system access.
CVE-2026-22184 1 Zlib 1 Zlib 2026-01-12 8.6 High
zlib versions up to and including 1.3.1.2 contain a global buffer overflow in the untgz utility. The TGZfname() function copies an attacker-supplied archive name from argv[] into a fixed-size 1024-byte static global buffer using an unbounded strcpy() call without length validation. Supplying an archive name longer than 1024 bytes results in an out-of-bounds write that can lead to memory corruption, denial of service, and potentially code execution depending on compiler, build flags, architecture, and memory layout. The overflow occurs prior to any archive parsing or validation.
CVE-2025-35050 1 Newforma 2 Project Center, Project Center Server 2026-01-09 9.8 Critical
Newforma Info Exchange (NIX) accepts serialized .NET data via the '/remoteweb/remote.rem' endpoint, allowing a remote, unauthenticated attacker to execute arbitrary code with 'NT AUTHORITY\NetworkService' privileges. The vulnerable endpoint is used by Newforma Project Center Server (NPCS), so a compromised NIX system can be used to attack an associated NPCS system. To mitigate this vulnerability, restrict network access to the '/remoteweb/remote.rem' endpoint, for example using the IIS URL Rewrite Module.
CVE-2025-14705 2 Sgwbox, Shiguangwu 3 N3, N3 Firmware, Sgwbox N3 2026-01-09 9.8 Critical
A vulnerability was determined in Shiguangwu sgwbox N3 2.0.25. This affects an unknown function of the component SHARESERVER Feature. This manipulation of the argument params causes command injection. The attack can be initiated remotely. The exploit has been publicly disclosed and may be utilized. The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2025-14708 2 Sgwbox, Shiguangwu 3 N3, N3 Firmware, Sgwbox N3 2026-01-09 9.8 Critical
A weakness has been identified in Shiguangwu sgwbox N3 2.0.25. Affected by this vulnerability is an unknown functionality of the file /usr/sbin/http_eshell_server of the component WIREDCFGGET Interface. Executing manipulation of the argument params can lead to buffer overflow. The attack may be launched remotely. The exploit has been made available to the public and could be exploited. The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2025-14707 2 Sgwbox, Shiguangwu 3 N3, N3 Firmware, Sgwbox N3 2026-01-09 9.8 Critical
A security flaw has been discovered in Shiguangwu sgwbox N3 2.0.25. Affected is an unknown function of the file /usr/sbin/http_eshell_server of the component DOCKER Feature. Performing manipulation of the argument params results in command injection. The attack may be initiated remotely. The exploit has been released to the public and may be exploited. The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2025-6098 1 Utt 2 750w, 750w Firmware 2026-01-08 9.8 Critical
A vulnerability was found in UTT 进取 750W up to 5.0. It has been classified as critical. This affects the function strcpy of the file /goform/setSysAdm of the component API. The manipulation of the argument passwd1 leads to buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2019-25278 1 Iwt 1 Facesentry Access Control System 2026-01-08 7.5 High
FaceSentry Access Control System 6.4.8 contains a cleartext transmission vulnerability that allows remote attackers to intercept authentication credentials. Attackers can perform man-in-the-middle attacks to capture HTTP cookie authentication information during network communication.
CVE-2019-25291 1 Inim 1 Smartliving Smartlan 2026-01-08 7.5 High
INIM Electronics Smartliving SmartLAN/G/SI <=6.x contains hard-coded credentials in its Linux distribution image that cannot be changed through normal device operations. Attackers can exploit these persistent credentials to log in and gain unauthorized system access across multiple SmartLiving device models.
CVE-2025-15346 1 Wolfssl 1 Wolfssl 2026-01-08 N/A
A vulnerability in the handling of verify_mode = CERT_REQUIRED in the wolfssl Python package (wolfssl-py) causes client certificate requirements to not be fully enforced.  Because the WOLFSSL_VERIFY_FAIL_IF_NO_PEER_CERT flag was not included, the behavior effectively matched CERT_OPTIONAL: a peer certificate was verified if presented, but connections were incorrectly authenticated when no client certificate was provided.  This results in improper authentication, allowing attackers to bypass mutual TLS (mTLS) client authentication by omitting a client certificate during the TLS handshake.  The issue affects versions up to and including 5.8.2.
CVE-2017-20216 1 Flir 1 Thermal Camera 2026-01-08 9.8 Critical
FLIR Thermal Camera PT-Series firmware version 8.0.0.64 contains multiple unauthenticated remote command injection vulnerabilities in the controllerFlirSystem.php script. Attackers can execute arbitrary system commands as root by exploiting unsanitized POST parameters in the execFlirSystem() function through shell_exec() calls. Exploitation evidence was observed by the Shadowserver Foundation on 2026-01-06 (UTC).
CVE-2017-20214 1 Flir 1 Thermal Camera 2026-01-08 7.5 High
FLIR Thermal Camera F/FC/PT/D firmware version 8.0.0.64 contains hard-coded SSH credentials that cannot be changed through normal camera operations. Attackers can leverage these persistent, unmodifiable credentials to gain unauthorized remote access to the thermal camera system.
CVE-2025-64121 1 Nuvation Energy 1 Multi-stack Controller 2026-01-08 N/A
Authentication Bypass Using an Alternate Path or Channel vulnerability in Nuvation Energy Multi-Stack Controller (MSC) allows Authentication Bypass.This issue affects Multi-Stack Controller (MSC): from 2.3.8 before 2.5.1.
CVE-2025-64119 1 Nuvation Energy 1 Battery Management System 2026-01-08 N/A
A vulnerability in Nuvation Battery Management System allows Authentication Bypass.This issue affects Battery Management System: through 2.3.9.
CVE-2025-64120 1 Nuvation Energy 1 Multi-stack Controller 2026-01-08 N/A
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability in Nuvation Energy Multi-Stack Controller (MSC) allows OS Command Injection.This issue affects Multi-Stack Controller (MSC): from 2.3.8 before 2.5.1.
CVE-2025-14346 2026-01-08 9.8 Critical
WHILL Model C2 Electric Wheelchairs and Model F Power Chairs do not enforce authentication for Bluetooth connections. An attacker within range can pair with the device and issue movement commands, override speed restrictions, and manipulate configuration profiles without any credentials or user interaction.
CVE-2025-64125 1 Nuvation Energy 1 Ncloud Vpn Service 2026-01-08 N/A
A vulnerability in Nuvation Energy nCloud VPN Service allowed Network Boundary Bridging.This issue affected the nCloud VPN Service and was fixed on 2025-12-1 (December, 2025). End users do not have to take any action to mitigate the issue.
CVE-2026-21440 2026-01-08 N/A
AdonisJS is a TypeScript-first web framework. A Path Traversal vulnerability in AdonisJS multipart file handling may allow a remote attacker to write arbitrary files to arbitrary locations on the server filesystem. This impacts @adonisjs/bodyparser through version 10.1.1 and 11.x prerelease versions prior to 11.0.0-next.6. This issue has been patched in @adonisjs/bodyparser versions 10.1.2 and 11.0.0-next.6.
CVE-2025-68428 1 Parall 1 Jspdf 2026-01-08 8.6 High
jsPDF is a library to generate PDFs in JavaScript. Prior to version 4.0.0, user control of the first argument of the loadFile method in the node.js build allows local file inclusion/path traversal. If given the possibility to pass unsanitized paths to the loadFile method, a user can retrieve file contents of arbitrary files in the local file system the node process is running in. The file contents are included verbatim in the generated PDFs. Other affected methods are `addImage`, `html`, and `addFont`. Only the node.js builds of the library are affected, namely the `dist/jspdf.node.js` and `dist/jspdf.node.min.js` files. The vulnerability has been fixed in [email protected]. This version restricts file system access per default. This semver-major update does not introduce other breaking changes. Some workarounds areavailable. With recent node versions, jsPDF recommends using the `--permission` flag in production. The feature was introduced experimentally in v20.0.0 and is stable since v22.13.0/v23.5.0/v24.0.0. For older node versions, sanitize user-provided paths before passing them to jsPDF.
CVE-2026-0625 1 D-link 4 Dsl-2640b, Dsl-2740r, Dsl-2780b and 1 more 2026-01-08 N/A
Multiple D-Link DSL/DIR/DNS devices contain an authentication bypass and improper access control vulnerability in the dnscfg.cgi endpoint that allows an unauthenticated attacker to access DNS configuration functionality. By directly requesting this endpoint, an attacker can modify the device’s DNS settings without valid credentials, enabling DNS hijacking (“DNSChanger”) attacks that redirect user traffic to attacker-controlled infrastructure. In 2019, D-Link reported that this behavior was leveraged by the "GhostDNS" malware ecosystem targeting consumer and carrier routers. All impacted products were subsequently designated end-of-life/end-of-service, and no longer receive security updates. Exploitation evidence was observed by the Shadowserver Foundation on 2025-11-27 (UTC).