| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| Insecure Loading of Dynamic Link Libraries have been discovered in USB-CONVERTERCABLE DRIVER, which could allow local attackers to potentially disclose information or execute arbitray code on affected systems.
This issue affects USB-CONVERTERCABLE DRIVER:. |
| Insecure Loading of Dynamic Link Libraries have been discovered in HVAC Energy Saving Program, which could allow local attackers to potentially disclose information or execute arbitray code on affected systems.
This issue affects HVAC Energy Saving Program:. |
| Rufus is a utility that helps format and create bootable USB flash drives. A DLL hijacking vulnerability in Rufus 4.6.2208 and earlier versions allows an attacker loading and executing a malicious DLL with escalated privileges (since the executable has been granted higher privileges during the time of launch) due to the ability to inject a malicious `cfgmgr32.dll` in the same directory as the executable and have it side load automatically. This is fixed in commit `74dfa49`, which will be part of version 4.7. Users are advised to upgrade as soon as version 4.7 becomes available. There are no known workarounds for this vulnerability. |
| The installer of INZONE Hub 1.0.10.3 to 1.0.17.0 contains an issue with the DLL search path, which may lead to insecurely loading Dynamic Link Libraries. As a result, arbitrary code may be executed with the privilege of the user invoking the installer. |
| DLL search order hijacking vulnerability in the wave.exe executable for Windows 11, version 1.27.8. Exploitation of this vulnerability could allow attackers with local access to execute arbitrary code by placing an arbitrary file in the 'C:\Users<user>\AppData\Local\Temp' directory, which could lead to arbitrary code execution and persistence. This vulnerability is only replicable in versions of Windows 11 and does not affect earlier versions. |
| A vulnerability classified as critical has been found in Shanghai Bairui Information Technology SunloginClient 15.8.3.19819. This affects an unknown part in the library process.dll of the file sunlogin_guard.exe. The manipulation leads to uncontrolled search path. Local access is required to approach this attack. The complexity of an attack is rather high. The exploitability is told to be difficult. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way. |
| Acer Global Registration Service 1.0.0.3 contains an unquoted service path vulnerability in its service configuration that allows local users to potentially execute arbitrary code. Attackers can exploit the unquoted path in C:\Program Files (x86)\Acer\Registration\ to inject malicious executables that would run with elevated LocalSystem privileges during service startup. |
| A potential DLL hijacking vulnerability in the SanDisk PrivateAccess application for Windows that could lead to arbitrary code execution in the context of the system user. This vulnerability is only exploitable locally if an attacker has access to a copy of the user's vault or has already gained access into a user's system. This attack is limited to the system in context and cannot be propagated. |
| The service Bizerba Communication Server (BCS) has an unquoted service path. Due to the way Windows searches the executable for the BCS service, malicious programs can be executed. |
| OCS Inventory NG 2.3.0.0 contains an unquoted service path vulnerability that allows local attackers to escalate privileges to system level. Attackers can place a malicious executable in the unquoted service path and trigger the service restart to execute code with elevated system privileges. |
| ActFax 10.10 contains an unquoted service path vulnerability that allows local attackers to potentially escalate privileges by exploiting the ActiveFaxServiceNT service configuration. Attackers with write permissions to Program Files directories can inject a malicious ActSrvNT.exe executable to gain elevated system access when the service restarts. |
| A search path or unquoted item vulnerability in Faronics Deep Freeze Server Standard, which affects versions 8.30.020.4627 and earlier. This vulnerability affects the DFServ.exe file. An attacker with local user privileges could exploit this vulnerability to replace the legitimate DFServ.exe service executable with a malicious file of the same name and located in a directory that has a higher priority than the legitimate directory. Thus, when the service starts, it will run the malicious file instead of the legitimate executable, allowing the attacker to execute arbitrary code, gain unauthorized access to the compromised system or stop the service from running. |
| An Uncontrolled Search Path Element vulnerability in B&R Industrial Automation Scene Viewer, B&R Industrial Automation Automation Runtime, B&R Industrial Automation mapp Vision, B&R Industrial Automation mapp View, B&R Industrial Automation mapp Cockpit, B&R Industrial Automation mapp Safety, B&R Industrial Automation VC4, B&R Industrial Automation APROL, B&R Industrial Automation CAN Driver, B&R Industrial Automation CAN Driver CC770, B&R Industrial Automation CAN Driver SJA1000, B&R Industrial Automation Tou0ch Lock, B&R Industrial Automation B&R Single-Touch Driver, B&R Industrial Automation Serial User Mode Touch Driver, B&R Industrial Automation Windows Settings Changer (LTSC), B&R Industrial Automation Windows Settings Changer (2019 LTSC), B&R Industrial Automation Windows 10 Recovery Solution, B&R Industrial Automation ADI driver universal, B&R Industrial Automation ADI Development Kit, B&R Industrial Automation ADI .NET SDK, B&R Industrial Automation SRAM driver, B&R Industrial Automation HMI Service Center, B&R Industrial Automation HMI Service Center Maintenance, B&R Industrial Automation Windows 10 IoT Enterprise 2019 LTSC, B&R Industrial Automation KCF Editor could allow an authenticated local attacker to execute malicious code by placing specially crafted files in the loading search path..This issue affects Scene Viewer: before 4.4.0; Automation Runtime: before J4.93; mapp Vision: before 5.26.1; mapp View: before 5.24.2; mapp Cockpit: before 5.24.2; mapp Safety: before 5.24.2; VC4: before 4.73.2; APROL: before 4.4-01; CAN Driver: before 1.1.0; CAN Driver CC770: before 3.3.0; CAN Driver SJA1000: before 1.3.0; Tou0ch Lock: before 2.1.0; B&R Single-Touch Driver: before 2.0.0; Serial User Mode Touch Driver: before 1.7.1; Windows Settings Changer (LTSC): before 3.2.0; Windows Settings Changer (2019 LTSC): before 2.2.0; Windows 10 Recovery Solution: before 3.2.0; ADI driver universal: before 3.2.0; ADI Development Kit: before 5.5.0; ADI .NET SDK: before 4.1.0; SRAM driver: before 1.2.0; HMI Service Center: before 3.1.0; HMI Service Center Maintenance: before 2.1.0; Windows 10 IoT Enterprise 2019 LTSC: through 1.1; KCF Editor: before 1.1.0. |
| Voltronic Power ViewPower through 1.04-21353 and PowerShield Netguard before 1.04-23292 allows a remote attacker to configure the system via an unspecified web interface. An unauthenticated remote attacker can make changes to the system including: changing the web interface admin password, view/change system configuration, enumerate connected UPS devices and shut down connected UPS devices. This extends to being able to configure operating system commands that should run if the system detects a connected UPS shutting down. |
| A flaw has been found in Artifex MuPDF up to 1.26.1 on Windows. The impacted element is the function get_system_dpi of the file platform/x11/win_main.c. This manipulation causes uncontrolled search path. The attack requires local access. The attack is considered to have high complexity. The exploitability is regarded as difficult. Upgrading to version 1.26.2 is sufficient to resolve this issue. Patch name: ebb125334eb007d64e579204af3c264aadf2e244. Upgrading the affected component is recommended. |
| Uncontrolled search path in some software installer for some VTune(TM) Profiler software and Intel(R) oneAPI Base Toolkits before version 2025.0. within Ring 3: User Applications may allow an escalation of privilege. System software adversary with an authenticated user combined with a high complexity attack may enable escalation of privilege. This result may potentially occur via local access when attack requirements are present without special internal knowledge and requires active user interaction. The potential vulnerability may impact the confidentiality (high), integrity (high) and availability (high) of the vulnerable system, resulting in subsequent system confidentiality (none), integrity (none) and availability (none) impacts. |
| The Dyson MQTT server (2022 and possibly later) allows publications and subscriptions by a client that has the correct values of AWS_ACCESS_KEY_ID, AWS_SECRET_ACCESS_KEY, AWS_SESSION_TOKEN, and device serial number, even if a device (such as a Pure Hot+Cool device) has been removed and is not visible in the supported MyDyson app. This could allow an unexpected actor to obtain control and set the room temperature (up to 37 Celsius) if ownership of the device is transferred without wiping the device. NOTE: the Supplier's position is that this is a potential vulnerability that dates back 4 years ago in 2022 and "we are unable to replicate that anymore." Based on the submitted report, in order to leverage this issue, an attacker needs to own a Dyson device with full privileges, sniff for the AWS credentials, and then transfer ownership of that Dyson device to the victim. Even if these steps were successfully accomplished, the attacker only acquires the ability to configure the Dyson device within its safe operating range, and does not acquire the ability to execute code on the device or obtain sensitive information. |
| Uncontrolled search path in Intel(R) Graphics Command Center Service bundled in some Intel(R) Graphics Windows DCH driver software before versions 31.0.101.3790/31.0.101.2114 may allow an authenticated user to potentially enable escalation of privilege via local access. |
| A vulnerability has been identified in HiMed Cockpit 12 pro (J31032-K2017-H259) (All versions >= V11.5.1 < V11.6.2), HiMed Cockpit 14 pro+ (J31032-K2017-H435) (All versions >= V11.5.1 < V11.6.2), HiMed Cockpit 18 pro (J31032-K2017-H260) (All versions >= V11.5.1 < V11.6.2), HiMed Cockpit 18 pro+ (J31032-K2017-H436) (All versions >= V11.5.1 < V11.6.2). The Kiosk Mode of the affected devices contains a restricted desktop environment escape vulnerability. This could allow an unauthenticated local attacker to escape the restricted environment and gain access to the underlying operating system. |
| Crucial Storage Executive installer versions prior to 11.08.082025.00 contain a DLL preloading vulnerability. During installation, the installer runs with elevated privileges and loads Windows DLLs using an uncontrolled search path, which can cause a malicious DLL placed alongside the installer to be loaded instead of the intended system library. A local attacker who can convince a victim to run the installer from a directory containing the attacker-supplied DLL can achieve arbitrary code execution with administrator privileges. |