Filtered by vendor Siemens
Subscriptions
Total
2183 CVE
| CVE | Vendors | Products | Updated | CVSS v3.1 |
|---|---|---|---|---|
| CVE-2017-9939 | 1 Siemens | 1 Sipass Integrated | 2025-04-20 | N/A |
| A vulnerability was discovered in Siemens SiPass integrated (All versions before V2.70) that could allow an attacker with network access to the SiPass integrated server to bypass the authentication mechanism and perform administrative operations. | ||||
| CVE-2017-6872 | 1 Siemens | 4 Ozw672, Ozw672 Firmware, Ozw772 and 1 more | 2025-04-20 | N/A |
| A vulnerability was discovered in Siemens OZW672 (all versions) and OZW772 (all versions) that could allow an attacker with access to port 21/tcp to access or alter historical measurement data stored on the device. | ||||
| CVE-2017-6871 | 1 Siemens | 2 Simatic Wincc Sm\@rtclient, Simatic Wincc Sm\@rtclient Lite | 2025-04-20 | N/A |
| A vulnerability was discovered in Siemens SIMATIC WinCC Sm@rtClient for Android (All versions before V1.0.2.2) and SIMATIC WinCC Sm@rtClient for Android Lite (All versions before V1.0.2.2). An attacker with physical access to an unlocked mobile device, that has the affected app running, could bypass the app's authentication mechanism under certain conditions. | ||||
| CVE-2017-6873 | 1 Siemens | 4 Ozw672, Ozw672 Firmware, Ozw772 and 1 more | 2025-04-20 | N/A |
| A vulnerability was discovered in Siemens OZW672 (all versions) and OZW772 (all versions) that could allow an attacker to read and manipulate data in TLS sessions while performing a man-in-the-middle (MITM) attack on the integrated web server on port 443/tcp. | ||||
| CVE-2017-2688 | 1 Siemens | 1 Ruggedcom Rox I | 2025-04-20 | N/A |
| The integrated web server in Siemens RUGGEDCOM ROX I (all versions) at port 10000/TCP could allow remote attackers to perform actions with the privileges of an authenticated user, provided the targeted user has an active session and is induced into clicking on a malicious link or into visiting a malicious website, aka CSRF. | ||||
| CVE-2017-2687 | 1 Siemens | 1 Ruggedcom Rox I | 2025-04-20 | N/A |
| Siemens RUGGEDCOM ROX I (all versions) contain a vulnerability in the integrated web server at port 10000/TCP which is prone to reflected Cross-Site Scripting attacks if an unsuspecting user is induced to click on a malicious link. | ||||
| CVE-2017-2689 | 1 Siemens | 1 Ruggedcom Rox I | 2025-04-20 | N/A |
| Siemens RUGGEDCOM ROX I (all versions) allow an authenticated user to bypass access restrictions in the web interface at port 10000/TCP to obtain privileged file system access or change configuration settings. | ||||
| CVE-2017-13099 | 3 Arubanetworks, Siemens, Wolfssl | 4 Instant, Scalance W1750d, Scalance W1750d Firmware and 1 more | 2025-04-20 | N/A |
| wolfSSL prior to version 3.12.2 provides a weak Bleichenbacher oracle when any TLS cipher suite using RSA key exchange is negotiated. An attacker can recover the private key from a vulnerable wolfSSL application. This vulnerability is referred to as "ROBOT." | ||||
| CVE-2017-2686 | 1 Siemens | 1 Ruggedcom Rox I | 2025-04-20 | N/A |
| Siemens RUGGEDCOM ROX I (all versions) contain a vulnerability that could allow an authenticated user to read arbitrary files through the web interface at port 10000/TCP and access sensitive information. | ||||
| CVE-2017-6865 | 1 Siemens | 16 Pcs 7, Primary Setup Tool, Security Configuration Tool and 13 more | 2025-04-20 | N/A |
| A vulnerability has been identified in Primary Setup Tool (PST) (All versions < V4.2 HF1), SIMATIC Automation Tool (All versions < V3.0), SIMATIC NET PC-Software (All versions < V14 SP1), SIMATIC PCS 7 V8.1 (All versions), SIMATIC PCS 7 V8.2 (All versions < V8.2 SP1), SIMATIC STEP 7 (TIA Portal) V13 (All versions < V13 SP2), SIMATIC STEP 7 (TIA Portal) V14 (All versions < V14 SP1), SIMATIC STEP 7 V5.X (All versions < V5.6), SIMATIC WinAC RTX 2010 SP2 (All versions), SIMATIC WinAC RTX F 2010 SP2 (All versions), SIMATIC WinCC (TIA Portal) V13 (All versions < V13 SP2), SIMATIC WinCC (TIA Portal) V14 (All versions < V14 SP1), SIMATIC WinCC V7.2 and prior (All versions), SIMATIC WinCC V7.3 (All versions < V7.3 Update 15), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Upd1), SIMATIC WinCC flexible 2008 (All versions < flexible 2008 SP5), SINAUT ST7CC (All versions installed in conjunction with SIMATIC WinCC < V7.3 Update 15), SINEMA Server (All versions < V14), SINUMERIK 808D Programming Tool (All versions < V4.7 SP4 HF2), SMART PC Access (All versions < V2.3), STEP 7 - Micro/WIN SMART (All versions < V2.3), Security Configuration Tool (SCT) (All versions < V5.0). Specially crafted PROFINET DCP broadcast packets sent to the affected products on a local Ethernet segment (Layer 2) could cause a Denial-of-Service condition of some services. The services require manual restart to recover. | ||||
| CVE-2017-6867 | 1 Siemens | 3 Simatic Wincc, Simatic Wincc \(tia Portal\), Simatic Wincc Runtime | 2025-04-20 | N/A |
| A vulnerability was discovered in Siemens SIMATIC WinCC (V7.3 before Upd 11 and V7.4 before SP1), SIMATIC WinCC Runtime Professional (V13 before SP2 and V14 before SP1), SIMATIC WinCC (TIA Portal) Professional (V13 before SP2 and V14 before SP1) that could allow an authenticated, remote attacker who is member of the "administrators" group to crash services by sending specially crafted messages to the DCOM interface. | ||||
| CVE-2017-12739 | 1 Siemens | 2 Sm-2556, Sm-2556 Firmware | 2025-04-20 | N/A |
| An issue was discovered on Siemens SICAM RTUs SM-2556 COM Modules with the firmware variants ENOS00, ERAC00, ETA2, ETLS00, MODi00, and DNPi00. The integrated web server (port 80/tcp) of the affected devices could allow unauthenticated remote attackers to execute arbitrary code on the affected device. | ||||
| CVE-2017-9938 | 1 Siemens | 1 Simatic Logon | 2025-04-20 | N/A |
| A vulnerability was discovered in Siemens SIMATIC Logon (All versions before V1.6) that could allow specially crafted packets sent to the SIMATIC Logon Remote Access service on port 16389/tcp to cause a Denial-of-Service condition. The service restarts automatically. | ||||
| CVE-2017-12740 | 1 Siemens | 1 Logo\! Soft Comfort | 2025-04-20 | N/A |
| Siemens LOGO! Soft Comfort (All versions before V8.2) lacks integrity verification of software packages downloaded via an unprotected communication channel. This could allow a remote attacker to manipulate the software package while performing a Man-in-the-Middle (MitM) attack. | ||||
| CVE-2017-12738 | 1 Siemens | 2 Sm-2556, Sm-2556 Firmware | 2025-04-20 | N/A |
| An issue was discovered on Siemens SICAM RTUs SM-2556 COM Modules with the firmware variants ENOS00, ERAC00, ETA2, ETLS00, MODi00, and DNPi00. The integrated web server (port 80/tcp) of the affected devices could allow Cross-Site Scripting (XSS) attacks if unsuspecting users are tricked into clicking on a malicious link. | ||||
| CVE-2017-14023 | 1 Siemens | 2 Simatic Pcs7, Simatic Wincc | 2025-04-20 | 4.9 Medium |
| An Improper Input Validation issue was discovered in Siemens SIMATIC PCS 7 V8.1 prior to V8.1 SP1 with WinCC V7.3 Upd 13, and V8.2 all versions. The improper input validation vulnerability has been identified, which may allow an authenticated remote attacker who is a member of the administrators group to crash services by sending specially crafted messages to the DCOM interface. | ||||
| CVE-2017-2685 | 1 Siemens | 3 Sinumerik Integrate Access Mymachine\/ethernet, Sinumerik Integrate Operate Client, Sinumerik Operate | 2025-04-20 | N/A |
| Siemens SINUMERIK Integrate Operate Clients between 2.0.3.00.016 (including) and 2.0.6 (excluding) and between 3.0.4.00.032 (including) and 3.0.6 (excluding) contain a vulnerability that could allow an attacker to read and manipulate data in TLS sessions while performing a man-in-the-middle (MITM) attack. | ||||
| CVE-2017-6869 | 1 Siemens | 1 Viewport For Web Office Portal | 2025-04-20 | N/A |
| A vulnerability was discovered in Siemens ViewPort for Web Office Portal before revision number 1453 that could allow an unauthenticated remote user to upload arbitrary code and execute it with the permissions of the operating-system user running the web server by sending specially crafted network packets to port 443/TCP or port 80/TCP. | ||||
| CVE-2017-12741 | 1 Siemens | 76 Dk Standard Ethernet Controller, Dk Standard Ethernet Controller Firmware, Ek-ertec 200p and 73 more | 2025-04-20 | 7.5 High |
| Specially crafted packets sent to port 161/udp could cause a denial of service condition. The affected devices must be restarted manually. | ||||
| CVE-2016-8567 | 1 Siemens | 1 Sicam Pas\/pqs | 2025-04-20 | 9.8 Critical |
| An issue was discovered in Siemens SICAM PAS before 8.00. A factory account with hard-coded passwords is present in the SICAM PAS installations. Attackers might gain privileged access to the database over Port 2638/TCP. | ||||