| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| Due to a missing authentication check in the SAP NetWeaver application on IBM i-series, the application allows high privileged unauthorized users to read, modify, or delete sensitive information, as well as access administrative or privileged functionalities. This results in a high impact on the confidentiality, integrity, and availability of the application. |
| The Toshiba printers do not implement privileges separation. As for the affected products/models/versions, see the reference URL. |
| Toshiba printers contain hardcoded credentials. As for the affected products/models/versions, see the reference URL. |
| A flaw was found in grub2 where the grub_extcmd_dispatcher() function calls grub_arg_list_alloc() to allocate memory for the grub's argument list. However, it fails to check in case the memory allocation fails. Once the allocation fails, a NULL point will be processed by the parse_option() function, leading grub to crash or, in some rare scenarios, corrupt the IVT data. |
| A vulnerability has been found in E-Lins H685, H685f, H700, H720, H750, H820, H820Q, H820Q0 and H900 up to 3.2 and classified as critical. This vulnerability affects unknown code of the component OEM Backend. The manipulation leads to hard-coded credentials. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. It is recommended to change the configuration settings. The vendor was contacted early about this disclosure but did not respond in any way. |
| A vulnerability classified as critical has been found in IROAD X5 Mobile App up to 5.2.5 on Android. Affected is an unknown function of the component API Endpoint. The manipulation leads to hard-coded credentials. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way. |
| An authenticated user can disclose the cleartext password of a configured SMTP server via an HTTP GET request to the /config.php endpoint. |
| Certain models of routers from Billion Electric has a Plaintext Storage of a Password vulnerability. Remote attackers with administrator privileges can access the user settings page to retrieve plaintext passwords. |
| Kea configuration and API directives can be used to overwrite arbitrary files, subject to permissions granted to Kea. Many common configurations run Kea as root, leave the API entry points unsecured by default, and/or place the control sockets in insecure paths.
This issue affects Kea versions 2.4.0 through 2.4.1, 2.6.0 through 2.6.2, and 2.7.0 through 2.7.8. |
| An attacker with low privileges can manipulate the requested memory size, causing the application to use an invalid memory area. This could lead to a crash of the application but it does not affected other applications. |
| BAS-IP AV-01D, AV-01MD, AV-01MFD, AV-01ED, AV-01KD, AV-01BD, AV-01KBD, AV-02D, AV-02IDE, AV-02IDR, AV-02IPD, AV-02FDE, AV-02FDR, AV-03D, AV-03BD, AV-04AFD, AV-04ASD, AV-04FD, AV-04SD, AV-05FD, AV-05SD, AA-07BD, AA-07BDI, BA-04BD, BA-04MD, BA-08BD, BA-08MD, BA-12BD, BA-12MD, CR-02BD before firmware v3.9.2 allows authenticated attackers to read SIP account passwords via a crafted GET request. |
| An issue in Pure Data 0.54-0 and fixed in 0.54-1 allows a local attacker to escalate privileges via the set*id () function. |
| A local privilege escalation vulnerability in the SecuSUITE Server (System Configuration) of SecuSUITE versions 5.0.420 and earlier could allow a successful attacker that had gained control of code running under one of the system accounts listed in the configuration file to potentially issue privileged script commands. |
| An issue in Solar-Log 1000 before v2.8.2 and build 52-23.04.2013 was discovered to store plaintext passwords in the export.html, email.html, and sms.html files -- fixed with 3.0.0-60 11.10.2013 for SL 200, 500, 1000 / not existing for SL 250, 300, 1200, 2000, SL 50 Gateway, SL Base. |
| The Chirp Access app contains a hard-coded password, BEACON_PASSWORD. An attacker within Bluetooth range could change configuration settings within the Bluetooth beacon, effectively disabling the application's ability to notify users when they are near a Beacon-enabled access point. This variable cannot be used to change the configuration settings of the door readers or locksets and does not affect the ability for authorized users of the mobile application to lock or unlock access points. |
| Smart-tab Android app installed April 2023 or earlier contains an issue with plaintext storage of a password. If this vulnerability is exploited, an attacker with physical access to the device may retrieve the credential information and spoof the device to access the related external service. |
| CWE-250: Execution with Unnecessary Privileges |
| A vulnerability has been identified in SIMATIC BATCH V9.1 (All versions), SIMATIC Information Server 2020 (All versions < V2020 SP2 Update 5), SIMATIC Information Server 2022 (All versions < V2022 SP1 Update 2), SIMATIC PCS 7 V9.1 (All versions < V9.1 SP2 UC06), SIMATIC Process Historian 2020 (All versions < V2020 SP2 Update 5), SIMATIC Process Historian 2022 (All versions < V2022 SP1 Update 2), SIMATIC WinCC Runtime Professional V18 (All versions < V18 Update 5), SIMATIC WinCC Runtime Professional V19 (All versions < V19 Update 3), SIMATIC WinCC V7.4 (All versions), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 18), SIMATIC WinCC V8.0 (All versions < V8.0 Update 5). The affected products run their DB server with elevated privileges which could allow an authenticated attacker to execute arbitrary OS commands with administrative privileges. |
| A vulnerability classified as problematic has been found in Audi Universal Traffic Recorder App 2.0. Affected is an unknown function of the component FTP Credentials. The manipulation leads to use of hard-coded password. Attacking locally is a requirement. The complexity of an attack is rather high. The exploitability is told to be difficult. The exploit has been disclosed to the public and may be used. Upgrading to version 2.89 and 2.90 is able to address this issue. It is recommended to upgrade the affected component. The vendor was contacted early about these issues and acted very professional. Version 2.89 is fixing this issue for new customers and 2.90 is going to fix it for existing customers. |
| The authenticated SCU firmware command of the firmware for Mennekes Smart / Premium Chargingpoints can be abused for command execution because OS commands are improperly neutralized when certain fields are passed to the underlying OS. |