Vendors |
Products |
Updated |
CVSS v3.1 |
| The program libraries (DLL) and binaries used by exos 9300 contain multiple hard-coded secrets. One notable example is the function "EncryptAndDecrypt" in the library Kaba.EXOS.common.dll. This algorithm uses a simple XOR encryption technique combined with a cryptographic key (cryptoKey) to transform each character of the input string. However, it's important to note that this implementation does not provide strong encryption and should not be considered secure for sensitive data. It's more of a custom encryption approach rather than a common algorithm used in cryptographic applications. The key itself is static and based on the founder's name of the company. The functionality is for example used to encrypt the user PINs before storing them in the MSSQL database. |
| In Eaton X303 3.5.16 - X303 3.5.17 Build 712, an attacker with network access to a XC-303 PLC can login as root over SSH. The root password is hardcoded in the firmware. NOTE: This vulnerability appears in versions that are no longer supported by Eaton. |
| An RPC service, which is part of exos 9300, is reachable on port 4000, run by the process FSMobilePhoneInterface.exe. This service is used for interprocess communication between services and the Kaba exos 9300 GUI, containing status information about the Access Managers. Interacting with the service does not require any authentication. Therefore, it is possible to send arbitrary status information about door contacts etc. without prior authentication. |
| A security issue was discovered in the Kubernetes Image Builder where default credentials are enabled during the Windows image build process when using the Nutanix or VMware OVA providers. These credentials, which allow root access, are disabled at the conclusion of the build. Kubernetes clusters are only affected if their nodes use VM images created via the Image Builder project and the vulnerability was exploited during the build process, which requires an attacker to access the build VM and modify the image while the build is in progress. |
| Multiple hardcoded credentials have been identified, which are allowed to sign-in to the exos 9300 datapoint server running on port 1004 and 1005. This server is used for relaying status information from and to the Access Managers. This information, among other things, is used to graphically visualize open doors and alerts. However, controlling the Access Managers via this interface is also possible.
To send and receive status information, authentication is necessary. The Kaba exos 9300 application contains hard-coded credentials for four different users, which are allowed to login to the datapoint server and receive as well as send information, including commands to open arbitrary doors. |
| Use of Hard-coded Credentials vulnerability in GoodWe Technologies Co., Ltd. GW1500‑XS allows anyone in physical proximity to the device to fully access the web interface of the inverter via Wi‑Fi.This issue affects GW1500‑XS: 1.1.2.1. |
| Precor touchscreen console P62, P80, and P82 contains a default SSH public key in the authorized_keys file. A remote attacker could use this key to gain root privileges. |
| Hardcoded credentials vulnerability in Trellix ePolicy Orchestrator (ePO) on Premise prior to 5.10 Service Pack 1 Update 2 allows an attacker with admin privileges on the ePO server to read the contents of the orion.keystore file, allowing them to access the ePO database encryption key. This was possible through using a hard coded password for the keystore. Access Control restrictions on the file mean this would not be exploitable unless the user is the system admin for the server that ePO is running on. |
| Use of hard-coded, the same among all vulnerable installations SQLite credentials vulnerability in SIGNUM-NET FARA allows to read and manipulate local-stored database.This issue affects FARA: through 5.0.80.34. |
| An authentication bypass vulnerability in the /web/um_open_telnet.cgi endpoint in Nexxt Solutions NCM-X1800 Mesh Router firmware UV1.2.7 and below, allowing an attacker to remotely enable the Telnet service without authentication, bypassing security controls. The Telnet server is then accessible with hard-coded credentials, allowing attackers to gain administrative shell access and execute arbitrary commands on the device. |
| An OEM IP camera manufactured by Shenzhen Liandian Communication Technology LTD exposes a Telnet service (port 23) with undocumented, default credentials. The Telnet service is enabled by default and is not disclosed or configurable via the device’s web interface or user manual. An attacker with network access can authenticate using default credentials and gain root-level shell access to the device. The affected firmware version is AppFHE1_V1.0.6.0 (Kernel: KerFHE1_PTZ_WIFI_V3.1.1, Hardware: HwFHE1_WF6_PTZ_WIFI_20201218). No official fix or firmware update is available, and the vendor could not be contacted. This vulnerability allows for remote code execution and privilege escalation. |
| Hard-coded Credentials in CoolKit eWeLlink app are before 5.4.x on Android and IOS allows local attacker to unauthorized access to sensitive data via Decryption algorithm and key obtained after decompiling app
|
| A hardcoded AES key in PMFW may result in a privileged attacker gaining access to the key, potentially resulting in internal debug information leakage. |
| A predefined administrative account is not documented and cannot
be deactivated. This account cannot be misused from the network, only by local
users on the server. |
| SSL Pinning Bypass in eWeLink Some hardware products allows local ATTACKER to Decrypt TLS communication and Extract secrets to clone the device via Flash the modified firmware |
| IXON B.V. IXrouter IX2400 (Industrial Edge Gateway) v3.0 was discovered to contain hardcoded root credentials stored in the non-volatile flash memory. This vulnerability allows physically proximate attackers to gain root access via UART or SSH. |
| Shenzhen TVT Digital Technology Co., Ltd. NVMS-9000 firmware (used by many white-labeled DVR/NVR/IPC products) contains hardcoded API credentials and an OS command injection flaw in its configuration services. The web/API interface accepts HTTP/XML requests authenticated with a fixed vendor credential string and passes user-controlled fields into shell execution contexts without proper argument sanitization. An unauthenticated remote attacker can leverage the hard-coded credential to access endpoints such as /editBlackAndWhiteList and inject shell metacharacters inside XML parameters, resulting in arbitrary command execution as root. The same vulnerable backend is also reachable in some models through a proprietary TCP service on port 4567 that accepts a magic GUID preface and base64-encoded XML, enabling the same command injection sink. Firmware releases from mid-February 2018 and later are reported to have addressed this issue. Exploitation evidence was observed by the Shadowserver Foundation on 2025-01-28 UTC. |
| Zohocorp's ManageEngine Analytics Plus and Zoho Analytics on-premise versions older than 6130 are vulnerable to an AD only account takeover because of a hardcoded sensitive token. |
| The `/etc/passwd` and `/etc/shadow` files reveal hard-coded password hashes for the operating system "root" user. The credentials are shipped with the update files. There is no option for deleting or changing their passwords for an enduser. An attacker can use the credentials to log into the device. Authentication can be performed via SSH backdoor or likely via physical access (UART shell). |