| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| MaLion for Windows and Mac versions 3.2.1 to 5.2.1 uses a hardcoded cryptographic key which may allow an attacker to alter the connection settings of Terminal Agent and spoof the Relay Service. |
| WN-AX1167GR firmware version 3.00 and earlier uses hardcoded credentials which may allow an attacker that can access the device to execute arbitrary code on the device. |
| WN-G300R3 firmware version 1.0.2 and earlier uses hardcoded credentials which may allow an attacker that can access the device to execute arbitrary code on the device. |
| The getUserzoneCookie function in Kaltura before 13.2.0 uses a hardcoded cookie secret to validate cookie signatures, which allows remote attackers to bypass an intended protection mechanism and consequently conduct PHP object injection attacks and execute arbitrary PHP code via a crafted userzone cookie. |
| D-Link DIR-850L REV. B (with firmware through FW208WWb02) devices have a hardcoded password of wrgac25_dlink.2013gui_dir850l for the Alphanetworks account upon device reset, which allows remote attackers to obtain root access via a TELNET session. |
| A vulnerability in motherboard console ports of line cards for Cisco ASR 1000 Series Aggregation Services Routers and Cisco cBR-8 Converged Broadband Routers could allow an unauthenticated, physical attacker to access an affected device's operating system. The vulnerability exists because an engineering console port is available on the motherboard of the affected line cards. An attacker could exploit this vulnerability by physically connecting to the console port on the line card. A successful exploit could allow the attacker to gain full access to the affected device's operating system. This vulnerability affects only Cisco ASR 1000 Series Routers that have removable line cards and Cisco cBR-8 Converged Broadband Routers, if they are running certain Cisco IOS XE 3.16 through 16.5 releases. Cisco Bug IDs: CSCvc65866, CSCve77132. |
| An issue was discovered on the D-Link DWR-932B router. Undocumented TELNET and SSH services provide logins to admin with the password admin and root with the password 1234. |
| EMC AppSync Server prior to 3.5.0.1 contains database accounts with hardcoded passwords that could potentially be exploited by malicious users to compromise the affected system. |
| An issue was discovered in heinekingmedia StashCat through 1.7.5 for Android. The keystore is locked with a hard-coded password. Therefore, everyone with access to the keystore can read the content out, for example the private key of the user. |
| MEDHOST Document Management System contains hard-coded credentials that are used for customer database access. An attacker with knowledge of the hard-coded credentials and the ability to communicate directly with the database may be able to obtain or modify sensitive patient and financial information. PostgreSQL is used as the Document Management System database. The account name is dms. The password is hard-coded throughout the application, and is the same across all installations. Customers do not have the option to change passwords. The dms account for PostgreSQL has access to the database schema for Document Management System. |
| An issue was discovered on the D-Link DWR-932B router. There is a hardcoded WPS PIN of 28296607. |
| The WePresent WiPG-1500 device with firmware 1.0.3.7 has a manufacturer account that has a hardcoded username / password. Once the device is set to DEBUG mode, an attacker can connect to the device using the telnet protocol and log into the device with the 'abarco' hardcoded manufacturer account. This account is not documented, nor is the DEBUG feature or the use of telnetd on port tcp/5885. |
| A hard-coded credentials issue was discovered on Mimosa Client Radios before 2.2.3, Mimosa Backhaul Radios before 2.2.3, and Mimosa Access Points before 2.2.3. These devices run Mosquitto, a lightweight message broker, to send information between devices. By using the vendor's hard-coded credentials to connect to the broker on any device (whether it be an AP, Client, or Backhaul model), an attacker can view all the messages being sent between the devices. If an attacker connects to an AP, the AP will leak information about any clients connected to it, including the serial numbers, which can be used to remotely factory reset the clients via a page in their web interface. |
| ACTi cameras including the D, B, I, and E series using firmware version A1D-500-V6.11.31-AC use non-random default credentials across all devices. A remote attacker can take complete control of a device using default admin credentials. |
| Multiple hardcoded credentials in Xsuite 2.x. |
| D-Link DIR-615 before v20.12PTb04 has a second admin account with a 0x1 BACKDOOR value, which might allow remote attackers to obtain access via a TELNET connection. |
| Hard coded weak credentials in Barracuda Load Balancer 5.0.0.015. |
| EMC ViPR SRM, EMC Storage M&R, EMC VNX M&R, EMC M&R for SAS Solution Packs (EMC ViPR SRM prior to 4.1, EMC Storage M&R prior to 4.1, EMC VNX M&R all versions, EMC M&R (Watch4Net) for SAS Solution Packs all versions) contain undocumented accounts with default passwords for Webservice Gateway and RMI JMX components. A remote attacker with the knowledge of the default password may potentially use these accounts to run arbitrary web service and remote procedure calls on the affected system. |
| An authentication bypass vulnerability exists in Schneider Electric's U.motion Builder software versions 1.2.1 and prior in which the system contains a hard-coded valid session. An attacker can use that session ID as part of the HTTP cookie of a web request, resulting in authentication bypass |
| Schneider Electric SoMachine Basic 1.4 SP1 and Schneider Electric Modicon TM221CE16R 1.3.3.3 devices have a hardcoded-key vulnerability. The Project Protection feature is used to prevent unauthorized users from opening an XML protected project file, by prompting the user for a password. This XML file is AES-CBC encrypted; however, the key used for encryption (SoMachineBasicSoMachineBasicSoMa) cannot be changed. After decrypting the XML file with this key, the user password can be found in the decrypted data. After reading the user password, the project can be opened and modified with the Schneider product. |