| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| An issue in H3C switch h3c-S1526 allows a remote attacker to obtain sensitive information via the S1526.cfg component. |
| Toshiba printers will display the password of the admin user in clear-text and additional passwords when sending 2 specific HTTP requests to the internal API. An attacker stealing the cookie of an admin or abusing a XSS vulnerability can recover this password in clear-text and compromise the printer. This vulnerability can be executed in combination with other vulnerabilities and difficult to execute alone. So, the CVSS score for this vulnerability alone is lower than the score listed in the "Base Score" of this vulnerability. For detail on related other vulnerabilities, please ask to the below contact point.
https://www.toshibatec.com/contacts/products/
As for the affected products/models/versions, see the reference URL. |
| The StrongDM Client insufficiently protected a pre-authentication token. Attackers could exploit this to intercept and reuse the token, potentially redeeming valid authentication credentials through a race condition. |
| An Information Disclosure vulnerability in the Telemetry component in TP-Link Kasa KP125M V1.0.0 and Tapo P125M 1.0.0 Build 220930 Rel.143947 allows attackers to observe device state via observing network traffic. |
| A vulnerability, which was classified as problematic, has been found in Enpass Password Manager up to 6.9.5 on Windows. This issue affects some unknown processing. The manipulation leads to cleartext storage of sensitive information in memory. An attack has to be approached locally. The complexity of an attack is rather high. The exploitation is known to be difficult. Upgrading to version 6.10.1 is able to address this issue. It is recommended to upgrade the affected component. |
| Information disclosure and exposure of authentication FTP credentials over the debug port 1604 in the MINOVA TTA service. This allows unauthenticated remote access to an active FTP account containing sensitive internal data and import structures. In environments where this FTP server is part of automated business processes (e.g. EDI or data integration), this could lead to data manipulation, extraction, or abuse. Debug ports 1602, 1603 and 1636 also expose service architecture information and system activity logs |
| A vulnerability classified as problematic was found in FNKvision FNK-GU2 up to 40.1.7. Affected by this vulnerability is an unknown functionality of the file /etc/shadow of the component MD5. The manipulation leads to risky cryptographic algorithm. It is possible to launch the attack on the physical device. The complexity of an attack is rather high. The exploitation appears to be difficult. The exploit has been disclosed to the public and may be used. |
| A vulnerability, which was classified as problematic, has been found in FNKvision FNK-GU2 up to 40.1.7. Affected by this issue is some unknown functionality of the file /rom/wpa_supplicant.conf. The manipulation leads to cleartext storage of sensitive information. It is possible to launch the attack on the physical device. The complexity of an attack is rather high. The exploitation is known to be difficult. The exploit has been disclosed to the public and may be used. |
| A vulnerability in the IPS Manager, Central Manager, and Local Manager communication workflow allows an attacker to control the destination of a request by manipulating the parameter, thereby leveraging sensitive information. |
| On affected platforms running Arista EOS with secure Vxlan configured, restarting the Tunnelsec agent will result in packets being sent over the secure Vxlan tunnels in the clear. |
| Sensitive data could be exposed to non- privileged users in a configuration file. Local access to the computer with a low- privileged account is required to access the configuration file containing the sensitive data. |
| Vulnerable data in transit in GE HealthCare EchoPAC products |
| A local user may find a configuration file on the client workstation with unencrypted sensitive data. This allows an attacker to impersonate the device or prevent the device from accessing the cloud portal which leads to a DoS. |
| Cleartext Transmission of Sensitive Information vulnerability in Crestron Automate VX allows Sniffing Network Traffic.
The device allows Web UI and API access over non-secure network ports which exposes sensitive information such as user passwords.
This issue affects Automate VX: from 5.6.8161.21536 through 6.4.0.49. |
| Cleartext transmission of sensitive information issue exists in Wi-Fi AP UNIT 'AC-WPS-11ac series'. If exploited, a man-in-the-middle attack may allow a remote unauthenticated attacker to eavesdrop the communication and obtain the authentication information. |
| A privilege escalation vulnerability was discovered that could allow a valid, authenticated LXCA user to escalate their permissions for a connected XCC instance when using LXCA as a Single Sign On (SSO) provider for XCC instances. |
| ** UNSUPPORTED WHEN ASSIGNED ** This vulnerability exists in D3D Security IP Camera D8801 due to usage of weak authentication scheme of the HTTP header protocol where authorization tag contain a Base-64 encoded username and password. A remote attacker could exploit this vulnerability by crafting a HTTP packet leading to exposure of user credentials of the targeted device. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. |
| dectalk-tts is a Node package to interact with the aeiou Dectalk web API. In `[email protected]`, network requests to the third-party API are sent over HTTP, which is unencrypted. Unencrypted traffic can be easily intercepted and modified by attackers. Anyone who uses the package could be the victim of a man-in-the-middle (MITM) attack. The network request was upgraded to HTTPS in version `1.0.1`. There are no workarounds, but some precautions include not sending any sensitive information and carefully verifying the API response before saving it. |
| Infoblox BloxOne v2.4 was discovered to contain a business logic flaw due to thick client vulnerabilities. |
| Bosscomm IF740 Firmware versions:11001.7078 & v11001.0000 and System versions: 6.25 & 6.00 were discovered to send communications to the update API in plaintext, allowing attackers to access sensitive information via a man-in-the-middle attack. |