| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| A vulnerability in an access control mechanism of Cisco Firepower Management Center (FMC) Software could allow an authenticated, remote attacker to access services beyond the scope of their authorization. This vulnerability is due to insufficient enforcement of access control in the affected software. An attacker could exploit this vulnerability by directly accessing the internal services of an affected device. A successful exploit could allow the attacker to overwrite policies and impact the configuration and operation of the affected device. |
| Multiple vulnerabilities in the web-based management interface of Cisco Firepower Management Center (FMC) Software could allow an unauthenticated, remote attacker to conduct a cross-site scripting (XSS) attack against a user of the interface. These vulnerabilities are due to insufficient validation of user-supplied input by the web-based management interface. An attacker could exploit these vulnerabilities by persuading a user of the interface to click a crafted link. A successful exploit could allow the attacker to execute arbitrary script code in the context of the interface or access sensitive, browser-based information. |
| Multiple vulnerabilities in the web-based management interface of Cisco Firepower Management Center (FMC) Software could allow an unauthenticated, remote attacker to conduct a cross-site scripting (XSS) attack against a user of the interface. These vulnerabilities are due to insufficient validation of user-supplied input by the web-based management interface. An attacker could exploit these vulnerabilities by persuading a user of the interface to click a crafted link. A successful exploit could allow the attacker to execute arbitrary script code in the context of the interface or access sensitive, browser-based information. |
| A vulnerability in the web UI of the Cisco Firepower Management Center (FMC) could allow an authenticated, remote attacker to execute arbitrary commands on an affected device. The vulnerability is due to insufficient input validation. An attacker could exploit this vulnerability by sending crafted input to the web UI. A successful exploit could allow the attacker to execute arbitrary commands within the affected device. |
| A vulnerability in the web UI of the Cisco Firepower Management Center (FMC) could allow an authenticated, remote attacker to execute arbitrary commands on an affected device. The vulnerability is due to insufficient input validation. An attacker could exploit this vulnerability by sending crafted input to the web UI. A successful exploit could allow the attacker to execute arbitrary commands within the affected device. |
| Multiple Cisco products are affected by a vulnerability in the Snort detection engine that could allow an unauthenticated, remote attacker to bypass a configured file policy for HTTP. The vulnerability is due to incorrect handling of an HTTP range header. An attacker could exploit this vulnerability by sending crafted HTTP packets through an affected device. A successful exploit could allow the attacker to bypass configured file policy for HTTP packets and deliver a malicious payload. |
| A vulnerability in the web management interface of Cisco Firepower Management Center (FMC) Software could allow an authenticated, remote attacker to bypass security protections and upload malicious files to the affected system. This vulnerability is due to improper validation of files uploaded to the web management interface of Cisco FMC Software. An attacker could exploit this vulnerability by uploading a maliciously crafted file to a device running affected software. A successful exploit could allow the attacker to store malicious files on the device, which they could access later to conduct additional attacks, including executing arbitrary code on the affected device with root privileges. |
| Multiple vulnerabilities in the web-based management interface of Cisco Firepower Management Center (FMC) Software could allow an authenticated, remote attacker to conduct a stored cross-site scripting (XSS) attack against a user of the interface of an affected device.
These vulnerabilities are due to insufficient validation of user-supplied input by the web-based management interface. An attacker could exploit these vulnerabilities by inserting crafted input into various data fields in an affected interface. A successful exploit could allow the attacker to execute arbitrary script code in the context of the interface, or access sensitive, browser-based information. In some cases, it is also possible to cause a temporary availability impact to portions of the FMC Dashboard. |
| Multiple vulnerabilities in the web-based management interface of Cisco Firepower Management Center (FMC) Software could allow an authenticated, remote attacker to conduct a stored cross-site scripting (XSS) attack against a user of the interface of an affected device.
These vulnerabilities are due to insufficient validation of user-supplied input by the web-based management interface. An attacker could exploit these vulnerabilities by inserting crafted input into various data fields in an affected interface. A successful exploit could allow the attacker to execute arbitrary script code in the context of the interface, or access sensitive, browser-based information. In some cases, it is also possible to cause a temporary availability impact to portions of the FMC Dashboard. |
| Multiple vulnerabilities in the web-based management interface of Cisco Firepower Management Center (FMC) Software could allow an authenticated, remote attacker to conduct a stored cross-site scripting (XSS) attack against a user of the interface of an affected device.
These vulnerabilities are due to insufficient validation of user-supplied input by the web-based management interface. An attacker could exploit these vulnerabilities by inserting crafted input into various data fields in an affected interface. A successful exploit could allow the attacker to execute arbitrary script code in the context of the interface, or access sensitive, browser-based information. In some cases, it is also possible to cause a temporary availability impact to portions of the FMC Dashboard. |
| Multiple vulnerabilities in the web-based management interface of Cisco Firepower Management Center (FMC) Software could allow an authenticated, remote attacker to execute arbitrary SQL injections on an affected device. These vulnerabilities exist due to improper input validation. An attacker could exploit these vulnerabilities by sending crafted SQL queries to an affected device. A successful exploit could allow the attacker to view information that they are not authorized to view, make changes to the system that they are not authorized to make, and execute commands within the underlying operating system that may affect the availability of the device. |
| A vulnerability in the web-based management interface of Cisco Firepower Management Center (FMC) Software could allow an authenticated, remote attacker to execute arbitrary code on the underlying operating system of an affected device. The vulnerability is due to insufficient input validation. An attacker could exploit this vulnerability by sending malicious commands to the web-based management interface of an affected device. A successful exploit could allow the attacker to execute arbitrary code on the underlying operating system of the affected device. |
| A vulnerability in the dashboard widget of Cisco Firepower Management Center (FMC) Software could allow an authenticated, remote attacker to cause a denial of service (DoS) condition on an affected device. The vulnerability is due to improper restrictions on XML entities. An attacker could exploit this vulnerability by crafting an XML-based widget on an affected server. A successful exploit could cause increased memory and CPU utilization, which could result in a DoS condition. |
| Multiple vulnerabilities in the web-based management interface of Cisco Firepower Management Center (FMC) Software could allow an authenticated, remote attacker to conduct a stored cross-site scripting (XSS) attack against a user of the interface of an affected device.
These vulnerabilities are due to insufficient validation of user-supplied input by the web-based management interface. An attacker could exploit these vulnerabilities by inserting crafted input into various data fields in an affected interface. A successful exploit could allow the attacker to execute arbitrary script code in the context of the interface, or access sensitive, browser-based information. In some cases, it is also possible to cause a temporary availability impact to portions of the FMC Dashboard. |
| A vulnerability in the file download feature of Cisco Firepower Management Center (FMC) Software could allow an authenticated, remote attacker to download arbitrary files from an affected system. This vulnerability is due to a lack of input sanitation. An attacker could exploit this vulnerability by sending a crafted HTTPS request. A successful exploit could allow the attacker to download arbitrary files from the affected system. |
| A vulnerability in the Simple Network Management Protocol (SNMP) access controls for Cisco FirePOWER Software for Adaptive Security Appliance (ASA) FirePOWER module, Cisco Firepower Management Center (FMC) Software, and Cisco Next-Generation Intrusion Prevention System (NGIPS) Software could allow an unauthenticated, remote attacker to perform an SNMP GET request using a default credential.
This vulnerability is due to the presence of a default credential for SNMP version 1 (SNMPv1) and SNMP version 2 (SNMPv2). An attacker could exploit this vulnerability by sending an SNMPv1 or SNMPv2 GET request to an affected device. A successful exploit could allow the attacker to retrieve sensitive information from the device using the default credential.
This attack will only be successful if SNMP is configured, and the attacker can only perform SNMP GET requests; write access using SNMP is not allowed. |
| A vulnerability in the web-based management interface of Cisco Firepower Management Center (FMC) could allow an authenticated, remote attacker to conduct a cross-site scripting (XSS) attack against a user of the web-based management interface of an affected system. The vulnerability is due to insufficient validation of user-supplied input in the web-based management interface of the affected system. An attacker could exploit this vulnerability by persuading a user to access a report containing malicious content. A successful exploit could allow the attacker to execute arbitrary script code in the context of the affected interface or access sensitive, browser-based information. Versions 6.2.3, 6.3.0, and 6.4.0 are affected. |
| A vulnerability in the web-based management interface of Cisco Secure Firewall Management Center (FMC) Software, formerly Firepower Management Center Software, could allow an authenticated, remote attacker to read arbitrary files from the underlying operating system.
This vulnerability exists because the web-based management interface does not properly validate user-supplied input. An attacker could exploit this vulnerability by sending a crafted HTTP request to an affected device. A successful exploit could allow the attacker to read arbitrary files on the underlying operating system of the affected device. The attacker would need valid user credentials to exploit this vulnerability. |
| Multiple vulnerabilities in the web-based management interface of Cisco Firepower Management Center (FMC) Software could allow an authenticated, remote attacker to execute arbitrary commands on the underlying operating system. To exploit these vulnerabilities, the attacker must have valid device credentials, but does not need Administrator privileges. These vulnerabilities are due to insufficient validation of user-supplied input for certain configuration options. An attacker could exploit these vulnerabilities by using crafted input within the device configuration GUI. A successful exploit could allow the attacker to execute arbitrary commands on the device, including on the underlying operating system, which could also affect the availability of the device. |
| Multiple vulnerabilities in the web-based management interface of Cisco Firepower Management Center (FMC) Software could allow an unauthenticated, remote attacker to conduct a cross-site scripting (XSS) attack against a user of the interface. These vulnerabilities are due to insufficient validation of user-supplied input by the web-based management interface. An attacker could exploit these vulnerabilities by persuading a user of the interface to click a crafted link. A successful exploit could allow the attacker to execute arbitrary script code in the context of the interface or access sensitive, browser-based information. |