Search Results (16752 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2024-36434 1 Supermicro 3 X11dph-i, X11dph-t, X11dph-tq 2026-04-15 7.5 High
An SMM callout vulnerability was discovered in Supermicro X11DPH-T, X11DPH-Tq, and X11DPH-i motherboards with BIOS firmware before 4.4.
CVE-2022-38692 2026-04-15 9.8 Critical
In BootROM, there is a missing size check for RSA keys in Certificate Type 0 validation. This could lead to memory buffer overflow without requiring additional execution privileges.
CVE-2024-47295 1 Seiko Epson Corporation 1 Web Config 2026-04-15 8.1 High
Insecure initial password configuration issue in SEIKO EPSON Web Config allows a remote unauthenticated attacker to set an arbitrary password and operate the device with an administrative privilege. As for the details of the affected versions, see the information provided by the vendor under [References].
CVE-2025-27109 2026-04-15 7.3 High
solid-js is a declarative, efficient, and flexible JavaScript library for building user interfaces. In affected versions Inserts/JSX expressions inside illegal inlined JSX fragments lacked escaping, allowing user input to be rendered as HTML when put directly inside JSX fragments. This issue has been addressed in version 1.9.4 and all users are advised to upgrade. There are no known workarounds for this vulnerability.
CVE-2024-41995 1 Ricoh Company Ltd 1 Javatm Platform 2026-04-15 7.5 High
Initialization of a resource with an insecure default vulnerability exists in JavaTM Platform Ver.12.89 and earlier. If this vulnerability is exploited, the product may be affected by some known TLS1.0 and TLS1.1 vulnerabilities. As for the specific products/models/versions of MFPs and printers that contain JavaTM Platform, see the information provided by the vendor.
CVE-2024-36433 1 Supermicro 3 X11dph-i, X11dph-t, X11dph-tq 2026-04-15 7.5 High
An arbitrary memory write vulnerability was discovered in Supermicro X11DPH-T, X11DPH-Tq, and X11DPH-i motherboards with BIOS firmware before 4.4.
CVE-2025-10948 1 Mikrotik 1 Routeros 2026-04-15 8.8 High
A vulnerability has been found in MikroTik RouterOS 7. This affects the function parse_json_element of the file /rest/ip/address/print of the component libjson.so. The manipulation leads to buffer overflow. The attack is possible to be carried out remotely. The exploit has been disclosed to the public and may be used. Upgrading to version 7.20.1 and 7.21beta2 mitigates this issue. You should upgrade the affected component. The vendor replied: "Our bug tracker reports that your issue has been fixed. This means that we plan to release a RouterOS update with this fix. Make sure to upgrade to the next release when it comes out."
CVE-2023-47310 1 Mikrotik 1 Routeros 2026-04-15 6.5 Medium
A misconfiguration in the default settings of MikroTik RouterOS 7 and fixed in v7.14 allows incoming IPv6 UDP traceroute packets.
CVE-2024-8313 2026-04-15 N/A
An Exposure of Sensitive System Information to an Unauthorized Control Sphere and Initialization of a Resource with an Insecure Default vulnerability in the SNMP component of B&R APROL <4.4-00P5 may allow an unauthenticated adjacent-based attacker to read and alter configuration using SNMP.
CVE-2024-11999 2026-04-15 8.8 High
CWE-1104: Use of Unmaintained Third-Party Components vulnerability exists that could cause complete control of the device when an authenticated user installs malicious code into HMI product.
CVE-2025-10392 1 Mercury 1 Km08-708h Giga Wifi Wave2 2026-04-15 9.8 Critical
A vulnerability was detected in Mercury KM08-708H GiGA WiFi Wave2 1.1.14. This affects an unknown function of the component HTTP Header Handler. The manipulation of the argument Host results in stack-based buffer overflow. The attack can be executed remotely. The exploit is now public and may be used.
CVE-2025-41245 1 Vmware 3 Aria Operations, Cloud Foundation, Tools 2026-04-15 4.9 Medium
VMware Aria Operations contains an information disclosure vulnerability. A malicious actor with non-administrative privileges in Aria Operations may exploit this vulnerability to disclose credentials of other users of Aria Operations.
CVE-2025-55730 1 Xwikisas 1 Xwiki-pro-macros 2026-04-15 10 Critical
XWiki Remote Macros provides XWiki rendering macros that are useful when migrating content from Confluence. Starting in version 1.0 and prior to version 1.26.5, missing escaping of the title in the confluence paste code macro allows remote code execution for any user who can edit any page. The classes parameter is used without escaping in XWiki syntax, thus allowing XWiki syntax injection which enables remote code execution. Version 1.26.5 has a fix for the issue.
CVE-2025-55903 2026-04-15 8.3 High
A HTML injection vulnerability exists in Perfex CRM v3.3.1. The application fails to sanitize user input in the "Bill To" address field within the estimate module. As a result, arbitrary HTML can be injected and rendered unescaped in client-facing documents.
CVE-2025-31930 2026-04-15 8.8 High
A vulnerability has been identified in IEC 1Ph 7.4kW Child socket (8EM1310-2EH04-0GA0) (All versions < V2.135), IEC 1Ph 7.4kW Child socket/ shutter (8EM1310-2EN04-0GA0) (All versions < V2.135), IEC 1Ph 7.4kW Parent cable 7m (8EM1310-2EJ04-3GA1) (All versions < V2.135), IEC 1Ph 7.4kW Parent cable 7m incl. SIM (8EM1310-2EJ04-3GA2) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket (8EM1310-2EH04-3GA1) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket incl. SIM (8EM1310-2EH04-3GA2) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket/ shutter (8EM1310-2EN04-3GA1) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket/ shutter SIM (8EM1310-2EN04-3GA2) (All versions < V2.135), IEC 3Ph 22kW Child cable 7m (8EM1310-3EJ04-0GA0) (All versions < V2.135), IEC 3Ph 22kW Child socket (8EM1310-3EH04-0GA0) (All versions < V2.135), IEC 3Ph 22kW Child socket/ shutter (8EM1310-3EN04-0GA0) (All versions < V2.135), IEC 3Ph 22kW Parent cable 7m (8EM1310-3EJ04-3GA1) (All versions < V2.135), IEC 3Ph 22kW Parent cable 7m incl. SIM (8EM1310-3EJ04-3GA2) (All versions < V2.135), IEC 3Ph 22kW Parent socket (8EM1310-3EH04-3GA1) (All versions < V2.135), IEC 3Ph 22kW Parent socket incl. SIM (8EM1310-3EH04-3GA2) (All versions < V2.135), IEC 3Ph 22kW Parent socket/ shutter (8EM1310-3EN04-3GA1) (All versions < V2.135), IEC 3Ph 22kW Parent socket/ shutter SIM (8EM1310-3EN04-3GA2) (All versions < V2.135), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA0) (All versions < V2.135), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA1) (All versions < V2.135), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA2) (All versions < V2.135), IEC ERK 3Ph 22 kW Child socket (8EM1310-3FH04-0GA0) (All versions < V2.135), IEC ERK 3Ph 22 kW Parent socket (8EM1310-3FH04-3GA1) (All versions < V2.135), IEC ERK 3Ph 22 kW Parent socket incl. SI (8EM1310-3FH04-3GA2) (All versions < V2.135), UL Commercial Cellular 48A NTEP (8EM1310-5HF14-1GA2) (All versions < V2.135), UL Commercial Child 40A w/ 15118 HW (8EM1310-4CF14-0GA0) (All versions < V2.135), UL Commercial Child 48A BA Compliant (8EM1315-5CG14-0GA0) (All versions < V2.135), UL Commercial Child 48A w/ 15118 HW (8EM1310-5CF14-0GA0) (All versions < V2.135), UL Commercial Parent 40A with Simcard (8EM1310-4CF14-1GA2) (All versions < V2.135), UL Commercial Parent 48A (USPS) (8EM1317-5CG14-1GA2) (All versions < V2.135), UL Commercial Parent 48A BA Compliant (8EM1315-5CG14-1GA2) (All versions < V2.135), UL Commercial Parent 48A with Simcard BA (8EM1310-5CF14-1GA2) (All versions < V2.135), UL Commercial Parent 48A, 15118, 25ft (8EM1310-5CG14-1GA1) (All versions < V2.135), UL Commercial Parent 48A, 15118, 25ft (8EM1314-5CG14-2FA2) (All versions < V2.135), UL Commercial Parent 48A, 15118, 25ft (8EM1315-5HG14-1GA2) (All versions < V2.135), UL Commercial Parent 48A,15118 25ft Sim (8EM1310-5CG14-1GA2) (All versions < V2.135), VersiCharge Blue™ 80A AC Cellular (8EM1315-7BG16-1FH2) (All versions < V2.135). Affected devices contain Modbus service enabled by default. This could allow an attacker connected to the same network to remotely control the EV charger.
CVE-2025-2441 2026-04-15 4.6 Medium
CWE-1188: Initialization of a Resource with an Insecure Default vulnerability exists that could lead to loss of confidentiality when a malicious user, having physical access, sets the radio in factory default mode where the product does not correctly initialize all data.
CVE-2024-1174 1 Hp 1 Thinpro 2026-04-15 8.2 High
Previous versions of HP ThinPro (prior to HP ThinPro 8.0 SP 8) could potentially contain security vulnerabilities. HP has released HP ThinPro 8.0 SP 8, which includes updates to mitigate potential vulnerabilities.
CVE-2025-34106 2026-04-15 N/A
A buffer overflow vulnerability exists in PDF Shaper versions 3.5 and 3.6 when converting a crafted PDF file to an image using the 'Convert PDF to Image' functionality. An attacker can exploit this vulnerability by tricking a user into opening a maliciously crafted PDF file, leading to arbitrary code execution under the context of the user. This vulnerability has been verified on Windows XP, 7, 8, and 10 platforms using the PDFTools.exe component.
CVE-2025-26503 1 Windriver 1 Vxworks 2026-04-15 6.7 Medium
A crafted system call argument can cause memory corruption.
CVE-2025-4440 1 H3c 1 Gr-1800ax 2026-04-15 8 High
A vulnerability was found in H3C GR-1800AX up to 100R008 and classified as critical. Affected by this issue is the function EnableIpv6 of the file /goform/aspForm. The manipulation of the argument param leads to buffer overflow. Access to the local network is required for this attack to succeed. The exploit has been disclosed to the public and may be used.