Search
Search Results (33 CVEs found)
| CVE | Vendors | Products | Updated | CVSS v3.1 |
|---|---|---|---|---|
| CVE-2026-0712 | 1 Sick Ag | 1 Incoming Goods Suite | 2026-01-16 | 7.6 High |
| An open redirect vulnerability has been identified in Grafana OSS that can be exploited to achieve XSS attacks. The vulnerability was introduced in Grafana v11.5.0. The open redirect can be chained with path traversal vulnerabilities to achieve XSS. Fixed in versions 12.0.2+security-01, 11.6.3+security-01, 11.5.6+security-01, 11.4.6+security-01 and 11.3.8+security-01 | ||||
| CVE-2026-22910 | 1 Sick Ag | 1 Tdc-x401gl | 2026-01-16 | 7.5 High |
| The device is deployed with weak and publicly known default passwords for certain hidden user levels, increasing the risk of unauthorized access. This represents a high risk to the integrity of the system. | ||||
| CVE-2026-22911 | 1 Sick Ag | 1 Tdc-x401gl | 2026-01-16 | 5.3 Medium |
| Firmware update files may expose password hashes for system accounts, which could allow a remote attacker to recover credentials and gain unauthorized access to the device. | ||||
| CVE-2026-22915 | 1 Sick Ag | 1 Tdc-x401gl | 2026-01-16 | 4.3 Medium |
| An attacker with low privileges may be able to read files from specific directories on the device, potentially exposing sensitive information. | ||||
| CVE-2026-22920 | 1 Sick Ag | 1 Tdc-x401gl | 2026-01-16 | 3.7 Low |
| The device's passwords have not been adequately salted, making them vulnerable to password extraction attacks. | ||||
| CVE-2026-22909 | 1 Sick Ag | 1 Tdc-x401gl | 2026-01-16 | 7.5 High |
| Certain system functions may be accessed without proper authorization, allowing attackers to start, stop, or delete installed applications, potentially disrupting system operations. | ||||
| CVE-2023-3273 | 2 Sick, Sick Ag | 3 Icr890-4, Icr890-4 Firmware, Icr890-4 | 2024-11-21 | 7.5 High |
| Improper Access Control in the SICK ICR890-4 could allow an unauthenticated remote attacker to affect the availability of the device by changing settings of the device such as the IP address based on missing access control. | ||||
| CVE-2023-3272 | 2 Sick, Sick Ag | 3 Icr890-4, Icr890-4 Firmware, Icr890-4 | 2024-11-21 | 7.5 High |
| Cleartext Transmission of Sensitive Information in the SICK ICR890-4 could allow a remote attacker to gather sensitive information by intercepting network traffic that is not encrypted. | ||||
| CVE-2023-3271 | 2 Sick, Sick Ag | 3 Icr890-4, Icr890-4 Firmware, Icr890-4 | 2024-11-21 | 8.2 High |
| Improper Access Control in the SICK ICR890-4 could allow an unauthenticated remote attacker to gather information about the system and download data via the REST API by accessing unauthenticated endpoints. | ||||
| CVE-2023-3270 | 2 Sick, Sick Ag | 3 Icr890-4, Icr890-4 Firmware, Icr890-4 | 2024-11-21 | 8.6 High |
| Exposure of Sensitive Information to an Unauthorized Actor in the SICK ICR890-4 could allow an unauthenticated remote attacker to retrieve sensitive information about the system. | ||||
| CVE-2023-35697 | 2 Sick, Sick Ag | 3 Icr890-4, Icr890-4 Firmware, Icr890-4 | 2024-11-21 | 5.3 Medium |
| Improper Restriction of Excessive Authentication Attempts in the SICK ICR890-4 could allow a remote attacker to brute-force user credentials. | ||||
| CVE-2023-35696 | 2 Sick, Sick Ag | 3 Icr890-4, Icr890-4 Firmware, Icr890-4 | 2024-11-21 | 7.5 High |
| Unauthenticated endpoints in the SICK ICR890-4 could allow an unauthenticated remote attacker to retrieve sensitive information about the device via HTTP requests. | ||||
| CVE-2024-11075 | 1 Sick Ag | 1 Incoming Goods Suite | 2024-11-19 | 8.8 High |
| A vulnerability in the Incoming Goods Suite allows a user with unprivileged access to the underlying system (e.g. local or via SSH) a privilege escalation to the administrative level due to the usage of component vendor Docker images running with root permissions. Exploiting this misconfiguration leads to the fact that an attacker can gain administrative control. over the whole system. | ||||