Filtered by vendor Moxa
Subscriptions
Total
298 CVE
| CVE | Vendors | Products | Updated | CVSS v3.1 |
|---|---|---|---|---|
| CVE-2016-9361 | 1 Moxa | 51 Nport 5100 Series Firmware, Nport 5100a Series Firmware, Nport 5110 and 48 more | 2025-04-20 | N/A |
| An issue was discovered in Moxa NPort 5110 versions prior to 2.6, NPort 5130/5150 Series versions prior to 3.6, NPort 5200 Series versions prior to 2.8, NPort 5400 Series versions prior to 3.11, NPort 5600 Series versions prior to 3.7, NPort 5100A Series & NPort P5150A versions prior to 1.3, NPort 5200A Series versions prior to 1.3, NPort 5150AI-M12 Series versions prior to 1.2, NPort 5250AI-M12 Series versions prior to 1.2, NPort 5450AI-M12 Series versions prior to 1.2, NPort 5600-8-DT Series versions prior to 2.4, NPort 5600-8-DTL Series versions prior to 2.4, NPort 6x50 Series versions prior to 1.13.11, NPort IA5450A versions prior to v1.4. Administration passwords can be retried without authenticating. | ||||
| CVE-2016-8359 | 1 Moxa | 19 Iologik E1200 Series Firmware, Iologik E1210, Iologik E1211 and 16 more | 2025-04-20 | 6.1 Medium |
| An issue was discovered in Moxa ioLogik E1210, firmware Version V2.4 and prior, ioLogik E1211, firmware Version V2.3 and prior, ioLogik E1212, firmware Version V2.4 and prior, ioLogik E1213, firmware Version V2.5 and prior, ioLogik E1214, firmware Version V2.4 and prior, ioLogik E1240, firmware Version V2.3 and prior, ioLogik E1241, firmware Version V2.4 and prior, ioLogik E1242, firmware Version V2.4 and prior, ioLogik E1260, firmware Version V2.4 and prior, ioLogik E1262, firmware Version V2.4 and prior, ioLogik E2210, firmware versions prior to V3.13, ioLogik E2212, firmware versions prior to V3.14, ioLogik E2214, firmware versions prior to V3.12, ioLogik E2240, firmware versions prior to V3.12, ioLogik E2242, firmware versions prior to V3.12, ioLogik E2260, firmware versions prior to V3.13, and ioLogik E2262, firmware versions prior to V3.12. The web application fails to sanitize user input, which may allow an attacker to inject script or execute arbitrary code (CROSS-SITE SCRIPTING). | ||||
| CVE-2017-13700 | 1 Moxa | 2 Eds-g512e, Eds-g512e Firmware | 2025-04-20 | N/A |
| An issue was discovered on MOXA EDS-G512E 5.1 build 16072215 devices. There is XSS in the administration interface. | ||||
| CVE-2017-7455 | 1 Moxa | 1 Mxview | 2025-04-20 | N/A |
| Moxa MXView 2.8 allows remote attackers to read web server's private key file, no access control. | ||||
| CVE-2016-8721 | 1 Moxa | 2 Awk-3131a, Awk-3131a Firmware | 2025-04-20 | 9.1 Critical |
| An exploitable OS Command Injection vulnerability exists in the web application 'ping' functionality of Moxa AWK-3131A Wireless Access Points running firmware 1.1. Specially crafted web form input can cause an OS Command Injection resulting in complete compromise of the vulnerable device. An attacker can exploit this vulnerability remotely. | ||||
| CVE-2016-8712 | 1 Moxa | 2 Awk-3131a, Awk-3131a Firmware | 2025-04-20 | 8.1 High |
| An exploitable nonce reuse vulnerability exists in the Web Application functionality of Moxa AWK-3131A Wireless AP running firmware 1.1. The device uses one nonce for all session authentication requests and only changes the nonce if the web application has been idle for 300 seconds. | ||||
| CVE-2016-8360 | 1 Moxa | 1 Softcms | 2025-04-20 | N/A |
| An issue was discovered in Moxa SoftCMS versions prior to Version 1.6. A specially crafted URL request sent to the SoftCMS ASP Webserver can cause a double free condition on the server allowing an attacker to modify memory locations and possibly cause a denial of service or the execution of arbitrary code. | ||||
| CVE-2016-9332 | 1 Moxa | 1 Softcms | 2025-04-20 | N/A |
| An issue was discovered in Moxa SoftCMS versions prior to Version 1.6. Moxa SoftCMS Webserver does not properly validate input. An attacker could provide unexpected values and cause the program to crash or excessive consumption of resources could result in a denial-of-service condition. | ||||
| CVE-2017-13699 | 1 Moxa | 2 Eds-g512e, Eds-g512e Firmware | 2025-04-20 | N/A |
| An issue was discovered on MOXA EDS-G512E 5.1 build 16072215 devices. The password encryption method can be retrieved from the firmware. This encryption method is based on a chall value that is sent in cleartext as a POST parameter. An attacker could reverse the password encryption algorithm to retrieve it. | ||||
| CVE-2016-9356 | 1 Moxa | 1 Dacenter | 2025-04-20 | N/A |
| An issue was discovered in Moxa DACenter Versions 1.4 and older. The application may suffer from an unquoted search path issue. | ||||
| CVE-2016-8727 | 1 Moxa | 2 Awk-3131a, Awk-3131a Firmware | 2025-04-20 | N/A |
| An exploitable information disclosure vulnerability exists in the Web Application functionality of Moxa AWK-3131A Wireless Access Point. Retrieving a series of URLs without authentication can reveal sensitive configuration and system information to an attacker. | ||||
| CVE-2016-9348 | 1 Moxa | 51 Nport 5100 Series Firmware, Nport 5100a Series Firmware, Nport 5110 and 48 more | 2025-04-20 | N/A |
| An issue was discovered in Moxa NPort 5110 versions prior to 2.6, NPort 5130/5150 Series versions prior to 3.6, NPort 5200 Series versions prior to 2.8, NPort 5400 Series versions prior to 3.11, NPort 5600 Series versions prior to 3.7, NPort 5100A Series & NPort P5150A versions prior to 1.3, NPort 5200A Series versions prior to 1.3, NPort 5150AI-M12 Series versions prior to 1.2, NPort 5250AI-M12 Series versions prior to 1.2, NPort 5450AI-M12 Series versions prior to 1.2, NPort 5600-8-DT Series versions prior to 2.4, NPort 5600-8-DTL Series versions prior to 2.4, NPort 6x50 Series versions prior to 1.13.11, NPort IA5450A versions prior to v1.4. A configuration file contains parameters that represent passwords in plaintext. | ||||
| CVE-2016-9363 | 1 Moxa | 51 Nport 5100 Series Firmware, Nport 5100a Series Firmware, Nport 5110 and 48 more | 2025-04-20 | N/A |
| An issue was discovered in Moxa NPort 5110 versions prior to 2.6, NPort 5130/5150 Series versions prior to 3.6, NPort 5200 Series versions prior to 2.8, NPort 5400 Series versions prior to 3.11, NPort 5600 Series versions prior to 3.7, NPort 5100A Series & NPort P5150A versions prior to 1.3, NPort 5200A Series versions prior to 1.3, NPort 5150AI-M12 Series versions prior to 1.2, NPort 5250AI-M12 Series versions prior to 1.2, NPort 5450AI-M12 Series versions prior to 1.2, NPort 5600-8-DT Series versions prior to 2.4, NPort 5600-8-DTL Series versions prior to 2.4, NPort 6x50 Series versions prior to 1.13.11, NPort IA5450A versions prior to v1.4. Buffer overflow vulnerability may allow an unauthenticated attacker to remotely execute arbitrary code. | ||||
| CVE-2017-16715 | 1 Moxa | 6 Nport 5110, Nport 5110 Firmware, Nport 5130 and 3 more | 2025-04-20 | N/A |
| An Information Exposure issue was discovered in Moxa NPort 5110 Version 2.2, NPort 5110 Version 2.4, NPort 5110 Version 2.6, NPort 5110 Version 2.7, NPort 5130 Version 3.7 and prior, and NPort 5150 Version 3.7 and prior. An attacker may be able to exploit a flaw in the handling of Ethernet frame padding that may allow for information exposure. | ||||
| CVE-2017-7456 | 1 Moxa | 1 Mxview | 2025-04-20 | N/A |
| Moxa MXView 2.8 allows remote attackers to cause a Denial of Service by sending overly long junk payload for the MXView client login credentials. | ||||
| CVE-2017-13703 | 1 Moxa | 2 Eds-g512e, Eds-g512e Firmware | 2025-04-20 | N/A |
| An issue was discovered on MOXA EDS-G512E 5.1 build 16072215 devices. A denial of service may occur. | ||||
| CVE-2016-8719 | 1 Moxa | 2 Awk-3131a, Awk-3131a Firmware | 2025-04-20 | 6.1 Medium |
| An exploitable reflected Cross-Site Scripting vulnerability exists in the Web Application functionality of Moxa AWK-3131A Wireless Access Point running firmware 1.1. Specially crafted input, in multiple parameters, can cause a malicious scripts to be executed by a victim. | ||||
| CVE-2017-13702 | 1 Moxa | 2 Eds-g512e, Eds-g512e Firmware | 2025-04-20 | N/A |
| An issue was discovered on MOXA EDS-G512E 5.1 build 16072215 devices. Cookies can be stolen, manipulated, and reused. | ||||
| CVE-2017-16727 | 1 Moxa | 4 Nport W2150a, Nport W2150a Firmware, Nport W2250a and 1 more | 2025-04-20 | N/A |
| A Credentials Management issue was discovered in Moxa NPort W2150A versions prior to 1.11, and NPort W2250A versions prior to 1.11. The default password is empty on the device. An unauthorized user can access the device without a password. An unauthorized user has the ability to completely compromise the confidentiality and integrity of the wireless traffic. | ||||
| CVE-2017-13698 | 1 Moxa | 2 Eds-g512e, Eds-g512e Firmware | 2025-04-20 | N/A |
| An issue was discovered on MOXA EDS-G512E 5.1 build 16072215 devices. An attacker could extract public and private keys from the firmware image available on the MOXA website and could use them against a production switch that has the default keys embedded. | ||||