| In Patient Information Center iX (PICiX) Versions C.02, C.03, the
software parses a formatted message or structure but does not handle or
incorrectly handles a length field that is inconsistent with the actual
length of the associated data, causing the application on the
surveillance station to restart.
|
| Delta Electronics TPEditor Versions 1.97 and prior. A heap-based buffer overflow may be exploited by processing a specially crafted project file. Successful exploitation of this vulnerability may allow an attacker to read/modify information, execute arbitrary code, and/or crash the application. |
| Delta Electronics TPEditor Versions 1.97 and prior. A stack-based buffer overflow may be exploited by processing a specially crafted project file. Successful exploitation of this vulnerability may allow an attacker to read/modify information, execute arbitrary code, and/or crash the application. |
| In Patient Information Center iX (PICiX) Versions C.02, C.03,
PerformanceBridge Focal Point Version A.01, the product receives input
that is expected to be well-formed (i.e., to comply with a certain
syntax) but it does not validate or incorrectly validates that the input
complies with the syntax, causing the certificate enrollment service to
crash. It does not impact monitoring but prevents new devices from
enrolling.
|
| Delta Electronics TPEditor Versions 1.97 and prior. An out-of-bounds read may be exploited by processing specially crafted project files. Successful exploitation of this vulnerability may allow an attacker to read/modify information, execute arbitrary code, and/or crash the application. |
| Advantech WebAccess HMI Designer, Versions 2.1.9.31 and prior. Processing specially crafted project files lacking proper validation of user supplied data may cause a stack-based buffer overflow, which may allow remote code execution, disclosure/modification of information, or cause the application to crash. |
| In Patient Information Center iX (PICiX) Versions B.02, C.02, C.03, the
software saves user-provided information into a comma-separated value
(CSV) file, but it does not neutralize or incorrectly neutralizes
special elements that could be interpreted as a command when the file is
opened by spreadsheet software.
|
| Advantech WebAccess HMI Designer, Versions 2.1.9.31 and prior. An out-of-bounds read vulnerability may be exploited by processing specially crafted project files, which may allow an attacker to read information. |
| Advantech WebAccess HMI Designer, Versions 2.1.9.31 and prior. Multiple heap-based buffer overflow vulnerabilities may be exploited by opening specially crafted project files that may overflow the heap, which may allow remote code execution, disclosure/modification of information, or cause the application to crash. |
| Delta Industrial Automation CNCSoft ScreenEditor, Versions 1.01.23 and prior. Multiple out-of-bounds read vulnerabilities may be exploited by processing specially crafted project files, which may allow an attacker to read information. |
| Delta Industrial Automation CNCSoft ScreenEditor, Versions 1.01.23 and prior. Multiple stack-based buffer overflow vulnerabilities may be exploited by processing specially crafted project files, which may allow an attacker to read/modify information, execute arbitrary code, and/or crash the application. |
| GoPro gpmf-parser 1.5 has a heap out-of-bounds read and segfault in GPMF_ScaledData(). Parsing malicious input can result in a crash or information disclosure. |
| Espressif ESP-IDF 2.x, 3.0.x through 3.0.9, 3.1.x through 3.1.7, 3.2.x through 3.2.3, 3.3.x through 3.3.2, and 4.0.x through 4.0.1 has a Buffer Overflow in BluFi provisioning in btc_blufi_recv_handler function in blufi_prf.c. An attacker can send a crafted BluFi protocol Write Attribute command to characteristic 0xFF01. With manipulated packet fields, there is a buffer overflow. |
| On Mercedes-Benz C Class AMG Premium Plus c220 BlueTec vehicles, the Bluetooth stack mishandles %x and %c format-string specifiers in a device name in the COMAND infotainment software. |
| Integer Overflow or Wraparound vulnerability in the XML RPC library of OpenRobotics ros_comm communications packages allows unauthenticated network traffic to cause unexpected behavior. This issue affects: OpenRobotics ros_comm communications packages Noetic and prior versions. Fixed in https://github.com/ros/ros_comm/pull/2065. |
| It is possible for an unauthenticated remote DCOM websocket connection to crash the Command Centre service due to an out-of-bounds buffer access. Affected versions are v8.20 prior to v8.20.1166(MR3), v8.10 prior to v8.10.1211(MR5), v8.00 prior to v8.00.1228(MR6), all versions of 7.90 and earlier. |
| Out of bounds read in ANGLE allowed a remote attacker to obtain sensitive data via a crafted HTML page. |
| Out of bounds read in networking in Google Chrome prior to 87.0.4280.88 allowed a remote attacker who had compromised the renderer process to obtain potentially sensitive information from process memory via a crafted HTML page. |
| Insufficient data validation in V8 in Google Chrome prior to 87.0.4280.88 allowed a remote attacker to potentially exploit heap corruption via a crafted HTML page. |