| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| Improper resource management in firmware of some Solidigm DC Products may allow an attacker with local or physical access to gain un-authorized access to a locked storage device. |
| Trilium Notes is an open-source, cross-platform hierarchical note taking application with focus on building large personal knowledge bases. In versions below 0.97.0, a brute-force protection bypass in the initial sync seed retrieval endpoint allows unauthenticated attackers to guess the login password without triggering rate limiting. Trilium is a single-user app without a username requirement, and brute-force protection bypass makes exploitation much more feasible. Multiple features provided by Trilium (e.g. MFA, share notes, custom request handler) indicate that Trilium can be exposed to the internet. This is fixed in version 0.97.0. |
| An unauthenticated user could discover account credentials via a brute-force attack without rate limiting |
| An issue was discovered in Bravura Security Fabric versions 12.3.x before 12.3.5.32784, 12.4.x before 12.4.3.35110, 12.5.x before 12.5.2.35950, 12.6.x before 12.6.2.37183, and 12.7.x before 12.7.1.38241. An unauthenticated attacker can cause a resource leak by issuing multiple failed login attempts through API SOAP. |
| Lack of protection against brute force attacks in Valmet DNA visualization in DNA Operate. The possibility to make an arbitrary number of login attempts without any rate limit gives an attacker an increased chance of guessing passwords and then performing switching operations. |
| The affected product does not limit the number of attempts for inputting
the correct PIN for a registered product, which may allow an attacker
to gain unauthorized access using brute-force methods if they possess a
valid device serial number. The API provides clear feedback when the
correct PIN is entered. This vulnerability was patched in a server-side
update on April 6, 2025. |
| A vulnerability was found in Windmill 1.380.0. It has been classified as problematic. Affected is an unknown function of the file backend/windmill-api/src/users.rs of the component HTTP Request Handler. The manipulation leads to improper restriction of excessive authentication attempts. It is possible to launch the attack remotely. The complexity of an attack is rather high. The exploitability is told to be difficult. Upgrading to version 1.390.1 is able to address this issue. The patch is identified as acfe7786152f036f2476f93ab5536571514fa9e3. It is recommended to upgrade the affected component. |
| A vulnerability exists in NSD570 login panel that does not restrict excessive authentication attempts. If exploited, this could
cause account takeover and unauthorized access to the system
when an attacker conducts brute-force attacks against the
equipment login. Note that the system supports only one concurrent session and implements a delay of more than a second
between failed login attempts making it difficult to automate the
attacks. |
| Use of fixed learning codes, one code to lock the car and the other code to unlock it, in the Key Fob Transmitter in Cyclone Matrix TRF Smart Keyless Entry System, which allows a replay attack.
Research was completed on the 2024 KIA Soluto. Attack confirmed on other KIA Models in Ecuador. |
| A vulnerability was found in Mercusys MW301R 1.0.2 Build 190726 Rel.59423n. It has been rated as problematic. This issue affects some unknown processing of the component Login. The manipulation leads to improper restriction of excessive authentication attempts. The attack can only be initiated within the local network. The complexity of an attack is rather high. The exploitation is known to be difficult. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way. |
| A lack of rate limiting in the OTP validation component of Digitory Multi Channel Integrated POS v1.0 allows attackers to gain access to the ordering system and place an excessive amount of food orders. |
| A vulnerability was found in Excitel Broadband Private my Excitel App 3.13.0 on Android. It has been classified as problematic. Affected is an unknown function of the component One-Time Password Handler. The manipulation leads to improper restriction of excessive authentication attempts. The vendor was contacted early about this disclosure but did not respond in any way. |
| SAP NetWeaver AS Java allows an unauthenticated attacker to brute force the login functionality in order to identify the legitimate user IDs. This has an impact on confidentiality but not on integrity or availability. |
| It is possible to bypass the clipping level of authentication attempts in SolaX Cloud through the use of the 'Forgot Password' functionality as an oracle. |
| A security vulnerability has been detected in VirtFusion up to 6.0.2. This vulnerability affects unknown code of the file /account/_settings of the component Email Change Handler. The manipulation leads to improper restriction of excessive authentication attempts. The attack can be initiated remotely. The exploit has been disclosed publicly and may be used. The vendor was contacted early about this disclosure but did not respond in any way. |
| Improper Restriction of Excessive Authentication Attempts vulnerability in CodePeople Appointment Hour Booking allows Removing Important Client Functionality.This issue affects Appointment Hour Booking: from n/a through 1.4.56. |
| The SupportCandy – Helpdesk & Customer Support Ticket System plugin for WordPress is vulnerable to Authentication Bypass in all versions up to, and including, 3.3.7. This is due to missing rate limiting on the OTP verification for guest login. This makes it possible for unauthenticated attackers to bypass authentication and gain unauthorized access to customer support tickets by brute forcing the 6-digit OTP code. |
| Authelia is an open-source authentication and authorization server providing two-factor authentication and single sign-on (SSO) for applications via a web portal. If users are allowed to sign in via both username and email the regulation system treats these as separate login events. This leads to the regulation limitations being effectively doubled assuming an attacker using brute-force to find a user password. It's important to note that due to the effective operation of regulation where no user-facing sign of their regulation ban being visible either via timing or via API responses, it's effectively impossible to determine if a failure occurs due to a bad username password combination, or a effective ban blocking the attempt which heavily mitigates any form of brute-force. This occurs because the records and counting process for this system uses the method utilized for sign in rather than the effective username attribute. This has a minimal impact on account security, this impact is increased naturally in scenarios when there is no two-factor authentication required and weak passwords are used. This makes it a bit easier to brute-force a password. A patch for this issue has been applied to versions 4.38.19, and 4.39.0. Users are advised to upgrade. Users unable to upgrade should 1. Not heavily modify the default settings in a way that ends up with shorter or less frequent regulation bans. The default settings effectively mitigate any potential for this issue to be exploited. and 2. Disable the ability for users to login via an email address. |
| A vulnerability was found in Digistar AG-30 Plus 2.6b. It has been classified as problematic. Affected is an unknown function of the component Login Page. The manipulation leads to improper restriction of excessive authentication attempts. The complexity of an attack is rather high. The exploitability is told to be difficult. The vendor was contacted early about this disclosure but did not respond in any way. |
| Unexpected authentication form rendering in HTML Form Adapter using only non-default redirectless mode in PingFederate allows authentication attempts which may enable brute force login attacks. |