| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| The WebSocket Application Programming Interface lacks restrictions on
the number of authentication requests. This absence of rate limiting may
allow an attacker to conduct denial-of-service attacks by suppressing
or mis-routing legitimate charger telemetry, or conduct brute-force
attacks to gain unauthorized access. |
| The WebSocket Application Programming Interface lacks restrictions on
the number of authentication requests. This absence of rate limiting may
allow an attacker to conduct denial-of-service attacks by suppressing
or mis-routing legitimate charger telemetry, or conduct brute-force
attacks to gain unauthorized access. |
| The Telnet service for Polycom ViewStation before 7.2.4 does not restrict the number of failed login attempts, which makes it easier for remote attackers to guess usernames and passwords via a brute force attack. |
| Lightwave ConsoleServer 3200 does not disconnect users after unsuccessful login attempts, which could allow remote attackers to conduct brute force password guessing. |
| The telnet server for 3Com hardware such as PS40 SuperStack II does not delay or disconnect remote attackers who provide an incorrect username or password, which makes it easier to break into the server via brute force password guessing. |
| Compaq/Microcom 6000 Access Integrator does not disconnect a client after a certain number of failed login attempts, which allows remote attackers to guess usernames or passwords via a brute force attack. |
| VAXstations running Open VMS 5.3 through 5.5-2 with VMS DECwindows or MOTIF do not properly disable access to user accounts that exceed the break-in limit threshold for failed login attempts, which makes it easier for attackers to conduct brute force password guessing. |
| Beck IPC GmbH IPC@CHIP telnet service does not delay or disconnect users from the service when bad passwords are entered, which makes it easier for remote attackers to conduct brute force password guessing attacks. |
| OpenClaw before 2026.3.25 contains a missing rate limiting vulnerability in Telegram webhook authentication that allows attackers to brute-force weak webhook secrets. The vulnerability enables repeated authentication guesses without throttling, permitting attackers to systematically guess webhook secrets through brute-force attacks. |
| OpenClaw before 2026.3.25 contains a pre-authentication rate-limit bypass vulnerability in webhook token validation that allows attackers to brute-force weak webhook secrets. The vulnerability exists because invalid webhook tokens are rejected without throttling repeated authentication attempts, enabling attackers to guess weak tokens through rapid successive requests. |
| Soosyze CMS 2.0 allows brute-force login attacks via the /user/login endpoint due to missing rate-limiting and lockout mechanisms. An attacker can repeatedly submit login attempts without restrictions, potentially gaining unauthorized administrative access. This vulnerability corresponds to CWE-307: Improper Restriction of Excessive Authentication Attempts. |
| Aviatrix Controller versions prior to 7.1.4208, 7.2.5090, and 8.0.0 do not enforce rate limiting on password reset attempts, allowing adversaries to brute force guess the 6-digit password reset PIN |
| An issue was discovered in Bravura Security Fabric versions 12.3.x before 12.3.5.32784, 12.4.x before 12.4.3.35110, 12.5.x before 12.5.2.35950, 12.6.x before 12.6.2.37183, and 12.7.x before 12.7.1.38241. An unauthenticated attacker can cause a resource leak by issuing multiple failed login attempts through API SOAP. |
| A security vulnerability has been detected in VirtFusion up to 6.0.2. This vulnerability affects unknown code of the file /account/_settings of the component Email Change Handler. The manipulation leads to improper restriction of excessive authentication attempts. The attack can be initiated remotely. The exploit has been disclosed publicly and may be used. The vendor was contacted early about this disclosure but did not respond in any way. |
| Use of fixed learning codes, one code to lock the car and the other code to unlock it, in the Key Fob Transmitter in Cyclone Matrix TRF Smart Keyless Entry System, which allows a replay attack.
Research was completed on the 2024 KIA Soluto. Attack confirmed on other KIA Models in Ecuador. |
| It is possible to bypass the clipping level of authentication attempts in SolaX Cloud through the use of the 'Forgot Password' functionality as an oracle. |
| An insufficient entropy vulnerability in the SecuSUITE Secure Client Authentication (SCA) Server of SecuSUITE versions 5.0.420 and earlier could allow an attacker to potentially enroll an attacker-controlled device to the victim’s account and telephone number. |
| A vulnerability exists in NSD570 login panel that does not restrict excessive authentication attempts. If exploited, this could
cause account takeover and unauthorized access to the system
when an attacker conducts brute-force attacks against the
equipment login. Note that the system supports only one concurrent session and implements a delay of more than a second
between failed login attempts making it difficult to automate the
attacks. |
| Improper resource management in firmware of some Solidigm DC Products may allow an attacker with local or physical access to gain un-authorized access to a locked storage device. |
| This vulnerability exists in Meon KYC solutions due to missing restrictions on the number of incorrect One-Time Password (OTP) attempts through certain API endpoints of login process. A remote attacker could exploit this vulnerability by performing a brute force attack on OTP, which could lead to gain unauthorized access to other user accounts. |