| Multiple buffer overflows in CimWebServer.exe in the WebView component in GE Intelligent Platforms Proficy HMI/SCADA - CIMPLICITY before 8.0 SIM 27, 8.1 before SIM 25, and 8.2 before SIM 19, and Proficy Process Systems with CIMPLICITY, allow remote attackers to execute arbitrary code via crafted data in packets to TCP port 10212, aka ZDI-CAN-1621 and ZDI-CAN-1624. |
| Unspecified vulnerability in the browser engine in Mozilla Firefox 3.5.x before 3.5.19, 3.6.x before 3.6.17, and 4.x before 4.0.1; Thunderbird before 3.1.10; and SeaMonkey before 2.0.14 allows remote attackers to cause a denial of service (memory corruption and application crash) or possibly execute arbitrary code via unknown vectors, a different vulnerability than CVE-2011-0070. |
| The Kepware DNP Master Driver for the KEPServerEX Communications Platform before 5.12.140.0 allows remote attackers to cause a denial of service (master-station infinite loop) via crafted DNP3 packets to TCP port 20000 and allows physically proximate attackers to cause a denial of service (master-station infinite loop) via crafted input over a serial line. |
| MatrikonOPC SCADA DNP3 OPC Server 1.2.0 allows remote attackers to cause a denial of service (master-station daemon crash) via a malformed DNP3 TCP packet from the IP address of an outstation. |
| Unspecified vulnerability in the browser engine in Mozilla Firefox 3.5.x before 3.5.19, 3.6.x before 3.6.17, and 4.x before 4.0.1; Thunderbird before 3.1.10; and SeaMonkey before 2.0.14 allows remote attackers to cause a denial of service (memory corruption and application crash) or possibly execute arbitrary code via unknown vectors, a different vulnerability than CVE-2011-0069. |
| Triangle MicroWorks SCADA Data Gateway 2.50.0309 through 3.00.0616, DNP3 .NET Protocol components 3.06.0.171 through 3.15.0.369, and DNP3 C libraries 3.06.0000 through 3.15.0000 allow remote attackers to cause a denial of service (infinite loop) via a crafted DNP3 TCP packet. |
| Schneider Electric Vijeo Citect 7.20 and earlier, CitectSCADA 7.20 and earlier, and PowerLogic SCADA 7.20 and earlier allow remote attackers to read arbitrary files, send HTTP requests to intranet servers, or cause a denial of service (CPU and memory consumption) via an XML document containing an external entity declaration in conjunction with an entity reference, related to an XML External Entity (XXE) issue. |
| The OSIsoft PI Interface for IEEE C37.118 before 1.0.6.158 allows remote attackers to cause a denial of service (instance shutdown and data-collection outage) via crafted C37.118 configuration packets that trigger an invalid read operation. |
| ProSoft RadioLinx ControlScape before 6.00.040 uses a deficient PRNG algorithm and seeding strategy for passphrases, which makes it easier for remote attackers to obtain access via a brute-force attack. |
| The DNP Master Driver in Software Toolbox TOP Server before 5.12.140.0 allows remote attackers to cause a denial of service (master-station infinite loop) via crafted DNP3 packets to TCP port 20000 and allows physically proximate attackers to cause a denial of service (master-station infinite loop) via crafted input over a serial line. |
| The (1) Catapult DNP3 I/O driver before 7.2.0.60 and the (2) GE Intelligent Platforms Proficy DNP3 I/O driver before 7.20k, as used in DNPDrv.exe (aka the DNP master station server) in GE Intelligent Platforms Proficy HMI/SCADA - CIMPLICITY and iFIX, allow remote attackers to cause a denial of service (infinite loop) via a crafted DNP3 TCP packet. |
| The DNP Master Driver in Alstom e-terracontrol 3.5, 3.6, and 3.7 allows physically proximate attackers to cause a denial of service (infinite loop and DNP3 service disruption) via crafted input over a serial line. |
| The (1) Catapult DNP3 I/O driver before 7.2.0.60 and the (2) GE Intelligent Platforms Proficy DNP3 I/O driver before 7.20k, as used in DNPDrv.exe (aka the DNP master station server) in GE Intelligent Platforms Proficy HMI/SCADA - CIMPLICITY and iFIX, allow physically proximate attackers to cause a denial of service (infinite loop) via crafted input over a serial line. |
| Array index error in win32k.sys in the kernel-mode drivers in Microsoft Windows Server 2008 R2 and R2 SP1 and Windows 7 Gold and SP1 allows remote attackers to cause a denial of service (reboot) via a crafted TrueType font file, aka "TrueType Font Parsing Vulnerability," a different vulnerability than CVE-2011-3402. |
| The Sierra Wireless AirLink Raven X EV-DO gateway 4221_4.0.11.003 and 4228_4.0.11.003 allows remote attackers to install Trojan horse firmware by leveraging cleartext credentials in a crafted (1) update or (2) reprogramming action. |
| Schneider Electric StruxureWare SCADA Expert Vijeo Citect 7.40, Vijeo Citect 7.20 through 7.30SP1, CitectSCADA 7.20 through 7.30SP1, StruxureWare PowerSCADA Expert 7.30 through 7.30SR1, and PowerLogic SCADA 7.20 through 7.20SR1 do not properly handle exceptions, which allows remote attackers to cause a denial of service via a crafted packet. |
| The DNP3 service in the Outstation component on Elecsys Director Gateway devices with kernel 2.6.32.11ael1 and earlier allows remote attackers to cause a denial of service (CPU consumption and communication outage) via crafted input. |
| An unspecified ActiveX control in WellinTech KingSCADA before 3.1.2, KingAlarm&Event before 3.1, and KingGraphic before 3.1.2 allows remote attackers to download arbitrary DLL code onto a client machine and execute this code via the ProjectURL property value. |
| Cross-site request forgery (CSRF) vulnerability in IBM Security QRadar SIEM 7.2 MR1 and earlier allows remote attackers to hijack the authentication of administrators for requests that modify console Auto Update settings. |
| The Buffer::Set function in core/cross/buffer.cc in the O3D plug-in in Google Chrome OS before 26.0.1410.57 does not prevent uninitialized data from remaining in a buffer, which might allow remote attackers to obtain sensitive information via unspecified vectors. |