CVE-2022-26045 1 Intel 2 Xmm 7560, Xmm 7560 Firmware 2025-02-05 3.3 Low
Improper buffer restrictions in some Intel(R) XMM(TM) 7560 Modem software before version M2_7560_R_01.2146.00 may allow a privileged user to potentially enable escalation of privilege via physical access.
CVE-2021-0876 1 Google 1 Android 2025-02-05 7.8 High
In PVRSRVBridgePhysmemNewRamBackedLockedPMR of the PowerVR kernel driver, a missing size check means there is a possible integer overflow that could allow out-of-bounds heap access. This could lead to local escalation of privilege with no additional execution privileges needed. User interaction is not needed for exploitation.Product: AndroidVersions: Android SoCAndroid ID: A-270400229
CVE-2021-0875 1 Google 1 Android 2025-02-05 7.8 High
In PVRSRVBridgeChangeSparseMem of the PowerVR kernel driver, a missing size check means there is a possible integer overflow that could allow out-of-bounds heap access. This could lead to local escalation of privilege with no additional execution privileges needed. User interaction is not needed for exploitation.Product: AndroidVersions: Android SoCAndroid ID: A-270400061
CVE-2021-0874 1 Google 1 Android 2025-02-05 7.8 High
In PVRSRVBridgeDevicememHistorySparseChange of the PowerVR kernel driver, a missing size check means there is a possible integer overflow that could allow out-of-bounds heap access. This could lead to local escalation of privilege with no additional execution privileges needed. User interaction is not needed for exploitation.Product: AndroidVersions: Android SoCAndroid ID: A-270399633
CVE-2021-0873 1 Google 1 Android 2025-02-05 7.8 High
In PVRSRVBridgeRGXKickRS of the PowerVR kernel driver, a missing size check means there is a possible integer overflow that could allow out-of-bounds heap access. This could lead to local escalation of privilege with no additional execution privileges needed. User interaction is not needed for exploitation.Product: AndroidVersions: Android SoCAndroid ID: A-270392711
CVE-2021-0872 1 Google 1 Android 2025-02-05 7.8 High
In PVRSRVBridgeRGXKickVRDM of the PowerVR kernel driver, a missing size check means there is a possible integer overflow that could allow out-of-bounds heap access. This could lead to local escalation of privilege with no additional execution privileges needed. User interaction is not needed for exploitation.Product: AndroidVersions: Android SoCAndroid ID: A-270401229
CVE-2023-2017 1 Shopware 1 Shopware 2025-02-05 8.8 High
Server-side Template Injection (SSTI) in Shopware 6 (<= v6.4.20.0, v6.5.0.0-rc1 <= v6.5.0.0-rc4), affecting both shopware/core and shopware/platform GitHub repositories, allows remote attackers with access to a Twig environment without the Sandbox extension to bypass the validation checks in `Shopware\Core\Framework\Adapter\Twig\SecurityExtension` and call any arbitrary PHP function and thus execute arbitrary code/commands via usage of fully-qualified names, supplied as array of strings, when referencing callables. Users are advised to upgrade to v6.4.20.1 to resolve this issue. This is a bypass of CVE-2023-22731.
CVE-2021-23165 1 Htmldoc Project 1 Htmldoc 2025-02-05 9.8 Critical
A flaw was found in htmldoc before v1.9.12. Heap buffer overflow in pspdf_prepare_outpages(), in ps-pdf.cxx may lead to execute arbitrary code and denial of service.
CVE-2022-32522 1 Schneider-electric 1 Interactive Graphical Scada System 2025-02-05 9.8 Critical
A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow, potentially leading to remote code execution when an attacker sends specially crafted mathematically reduced data request messages. Affected Products: IGSS Data Server - IGSSdataServer.exe (Versions prior to V15.0.0.22170)
CVE-2022-32523 1 Schneider-electric 1 Interactive Graphical Scada System 2025-02-05 9.8 Critical
A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow, potentially leading to remote code execution when an attacker sends specially crafted online data request messages. Affected Products: IGSS Data Server - IGSSdataServer.exe (Versions prior to V15.0.0.22170)
CVE-2022-32524 1 Schneider-electric 1 Interactive Graphical Scada System 2025-02-05 9.8 Critical
A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow, potentially leading to remote code execution when an attacker sends specially crafted time reduced data messages. Affected Products: IGSS Data Server - IGSSdataServer.exe (Versions prior to V15.0.0.22170)
CVE-2022-32525 1 Schneider-electric 1 Interactive Graphical Scada System 2025-02-05 9.8 Critical
A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow, potentially leading to remote code execution when an attacker sends specially crafted alarm data messages. Affected Products: IGSS Data Server - IGSSdataServer.exe (Versions prior to V15.0.0.22170)
CVE-2022-32526 1 Schneider-electric 1 Interactive Graphical Scada System 2025-02-05 9.8 Critical
A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow, potentially leading to remote code execution when an attacker sends specially crafted setting value messages. Affected Products: IGSS Data Server - IGSSdataServer.exe (Versions prior to V15.0.0.22170)
CVE-2022-32527 1 Schneider-electric 1 Interactive Graphical Scada System 2025-02-05 9.8 Critical
A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow, potentially leading to remote code execution when an attacker sends specially crafted alarm cache data messages. Affected Products: IGSS Data Server - IGSSdataServer.exe (Versions prior to V15.0.0.22170)
CVE-2022-32529 1 Schneider-electric 1 Interactive Graphical Scada System 2025-02-05 9.8 Critical
A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow, potentially leading to remote code execution when an attacker sends specially crafted log data request messages. Affected Products: IGSS Data Server - IGSSdataServer.exe (Versions prior to V15.0.0.22170)
CVE-2022-24324 1 Schneider-electric 1 Interactive Graphical Scada System 2025-02-05 9.8 Critical
A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow potentially leading to remote code execution when an attacker sends a specially crafted message. Affected Products: IGSS Data Server - IGSSdataServer.exe (Versions prior to V15.0.0.22073)
CVE-2022-2329 1 Schneider-electric 1 Interactive Graphical Scada System 2025-02-05 9.8 Critical
A CWE-190: Integer Overflow or Wraparound vulnerability exists that could cause heap-based buffer overflow, leading to denial of service and potentially remote code execution when an attacker sends multiple specially crafted messages. Affected Products: IGSS Data Server - IGSSdataServer.exe (Versions prior to V15.0.0.22073)
CVE-2022-32512 1 Schneider-electric 1 Canbrass 2025-02-05 5.3 Medium
A CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists that could cause remote code execution when a command which exploits this vulnerability is utilized. Affected Products: CanBRASS (Versions prior to V7.5.1)
CVE-2022-32517 1 Schneider-electric 2 Conext Combox, Conext Combox Firmware 2025-02-05 6.5 Medium
A CWE-1021: Improper Restriction of Rendered UI Layers or Frames vulnerability exists that could cause an adversary to trick the interface user/admin into interacting with the application in an unintended way when the product does not implement restrictions on the ability to render within frames on external addresses. Affected Products: Conextâ„¢ ComBox (All Versions)
CVE-2023-0595 1 Schneider-electric 4 Clearscada, Ecostruxure Geo Scada Expert 2019, Ecostruxure Geo Scada Expert 2020 and 1 more 2025-02-05 5.3 Medium
A CWE-117: Improper Output Neutralization for Logs vulnerability exists that could cause the misinterpretation of log files when malicious packets are sent to the Geo SCADA server's database web port (default 443). Affected products: EcoStruxure Geo SCADA Expert 2019, EcoStruxure Geo SCADA Expert 2020, EcoStruxure Geo SCADA Expert 2021(All Versions prior to October 2022), ClearSCADA (All Versions)