| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| Axeda agent (All versions) and Axeda Desktop Server for Windows (All versions) uses hard-coded credentials for its UltraVNC installation. Successful exploitation of this vulnerability could allow a remote authenticated attacker to take full remote control of the host operating system. |
| Rockwell Automation ISaGRAF Runtime Versions 4.x and 5.x includes the functionality of setting a password that is required to execute privileged commands. The password value passed to ISaGRAF Runtime is the result of encryption performed with a fixed key value using the tiny encryption algorithm (TEA) on an entered or saved password. A remote, unauthenticated attacker could pass their own encrypted password to the ISaGRAF 5 Runtime, which may result in information disclosure on the device. |
| By having access to the hard-coded cryptographic key for GE Reason RT430, RT431 & RT434 GNSS clocks in firmware versions prior to version 08A06, attackers would be able to intercept and decrypt encrypted traffic through an HTTPS connection. |
| GE UR firmware versions prior to version 8.1x supports web interface with read-only access. The device fails to properly validate user input, making it possible to perform cross-site scripting attacks, which may be used to send a malicious script. Also, UR Firmware web server does not perform HTML encoding of user-supplied strings. |
| A reflected cross-site scripting (XSS) vulnerability in the B. Braun Melsungen AG SpaceCom Version L81/U61 and earlier, and the Data module compactplus Versions A10 and A11 allows remote attackers to inject arbitrary web script or HTML into various locations. |
| Hard-coded credentials in the B. Braun Melsungen AG SpaceCom Version L81/U61 and earlier, and the Data module compactplus Versions A10 and A11 enable attackers with command line access to access the device’s Wi-Fi module. |
| An attacker may be able to inject client-side JavaScript code on multiple instances within all versions of Uffizio GPS Tracker. |
| The Weintek cMT product line is vulnerable to a cross-site scripting vulnerability, which could allow an unauthenticated remote attacker to inject malicious JavaScript code. |
| xArrow SCADA versions 7.2 and prior is vulnerable to cross-site scripting due to parameter ‘bdate’ of the resource xhisvalue.htm, which may allow an unauthorized attacker to execute arbitrary code. |
| xArrow SCADA versions 7.2 and prior is vulnerable to cross-site scripting due to parameter ‘edate’ of the resource xhisalarm.htm, which may allow an unauthorized attacker to execute arbitrary code. |
| xArrow SCADA versions 7.2 and prior permits unvalidated registry keys to be run with application-level privileges. |
| The AGG Software Web Server version 4.0.40.1014 and prior is vulnerable to cross-site scripting, which may allow an attacker to remotely execute arbitrary code. |
| When a non-existent resource is requested, the LCDS LAquis SCADA application (version 4.3.1.1011 and prior) returns error messages which may allow reflected cross-site scripting. |
| An attacker can gain full access (read/write/delete) to sensitive folders due to hard-coded credentials on KUKA KR C4 control software for versions prior to 8.7 or any product running KSS. |
| A vulnerability was found in GE Voluson S8. It has been rated as critical. This issue affects the Service Browser which itroduces hard-coded credentials. Attacking locally is a requirement. It is recommended to change the configuration settings. |
| A user with administrative privileges in Distributed Data Systems WebHMI 4.1.1.7662 can store a script that could impact other logged in users. |
| A Stored Cross-site scripting (XSS) vulnerability via MAster.php in Sourcecodetester Simple Client Management System (SCMS) 1.0 allows remote attackers to inject arbitrary web script or HTML via the vulnerable input fields. |
| The MiCODUS MV720 GPS tracker API server has an authentication mechanism that allows devices to use a hard-coded master password. This may allow an attacker to send SMS commands directly to the GPS tracker as if they were coming from the GPS owner’s mobile number. |
| Multiple globally default credentials exist across all CMS8000 devices, that once exposed, allow a threat actor with momentary physical access to gain privileged access to any device. Privileged credential access enables the extraction of sensitive patient information or modification of device parameters |
| Digital Alert Systems’ DASDEC software prior to version 4.1 contains a cross-site scripting (XSS) vulnerability that allows remote attackers to inject arbitrary web script or HTML via the SSH username, username field of the login page, or via the HTTP host header. The injected content is stored in logs and rendered when viewed in the web application. |