| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| An out-of-bounds read was addressed with improved input validation. This issue is fixed in macOS Ventura 13. An app may be able to execute arbitrary code with kernel privileges. |
| There are buffer overflow vulnerabilities in multiple underlying operating system processes that could lead to unauthenticated remote code execution by sending specially crafted packets via the PAPI protocol. Successful exploitation of these vulnerabilities result in the ability to execute arbitrary code as a privileged user on the underlying operating system.
|
| A vulnerability has been found in Tenda AC18 15.13.07.09 and classified as critical. Affected by this vulnerability is the function fromSetWirelessRepeat. The manipulation of the argument wpapsk_crypto5g leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-256999. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. |
| A vulnerability has been identified in RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2) (All versions < V8.2.1), RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2) (All versions < V8.2.1), SCALANCE M804PB (6GK5804-0AP00-2AA2) (All versions < V8.2.1), SCALANCE M812-1 ADSL-Router family (All versions < V8.2.1), SCALANCE M816-1 ADSL-Router family (All versions < V8.2.1), SCALANCE M826-2 SHDSL-Router (6GK5826-2AB00-2AB2) (All versions < V8.2.1), SCALANCE M874-2 (6GK5874-2AA00-2AA2) (All versions < V8.2.1), SCALANCE M874-3 (6GK5874-3AA00-2AA2) (All versions < V8.2.1), SCALANCE M874-3 3G-Router (CN) (6GK5874-3AA00-2FA2) (All versions < V8.2.1), SCALANCE M876-3 (6GK5876-3AA02-2BA2) (All versions < V8.2.1), SCALANCE M876-3 (ROK) (6GK5876-3AA02-2EA2) (All versions < V8.2.1), SCALANCE M876-4 (6GK5876-4AA10-2BA2) (All versions < V8.2.1), SCALANCE M876-4 (EU) (6GK5876-4AA00-2BA2) (All versions < V8.2.1), SCALANCE M876-4 (NAM) (6GK5876-4AA00-2DA2) (All versions < V8.2.1), SCALANCE MUB852-1 (A1) (6GK5852-1EA10-1AA1) (All versions < V8.2.1), SCALANCE MUB852-1 (B1) (6GK5852-1EA10-1BA1) (All versions < V8.2.1), SCALANCE MUM853-1 (A1) (6GK5853-2EA10-2AA1) (All versions < V8.2.1), SCALANCE MUM853-1 (B1) (6GK5853-2EA10-2BA1) (All versions < V8.2.1), SCALANCE MUM853-1 (EU) (6GK5853-2EA00-2DA1) (All versions < V8.2.1), SCALANCE MUM856-1 (A1) (6GK5856-2EA10-3AA1) (All versions < V8.2.1), SCALANCE MUM856-1 (B1) (6GK5856-2EA10-3BA1) (All versions < V8.2.1), SCALANCE MUM856-1 (CN) (6GK5856-2EA00-3FA1) (All versions < V8.2.1), SCALANCE MUM856-1 (EU) (6GK5856-2EA00-3DA1) (All versions < V8.2.1), SCALANCE MUM856-1 (RoW) (6GK5856-2EA00-3AA1) (All versions < V8.2.1), SCALANCE S615 EEC LAN-Router (6GK5615-0AA01-2AA2) (All versions < V8.2.1), SCALANCE S615 LAN-Router (6GK5615-0AA00-2AA2) (All versions < V8.2.1), SCALANCE SC-600 family (All versions). Affected devices improperly validate usernames during OpenVPN authentication. This could allow an attacker to get partial invalid usernames accepted by the server. |
| Feather-Sequalize cleanQuery method uses insecure recursive logic to filter unsupported keys from the query object. This results in a Remote Code Execution (RCE) with privileges of application. |
| The ip-utils package through 2.4.0 for Node.js might allow SSRF because some IP addresses (such as 0x7f.1) are improperly categorized as globally routable via a falsy isPrivate return value. |
| There are many buffer overflow vulnerabilities present in several CGI binaries of the charging station.This issue affects Iocharger firmware for AC model chargers beforeversion 24120701.
Likelihood: High – Given the prevalence of these buffer overflows, and the clear error message of the web server, an attacker is very likely to be able to find these vulnerabilities.
Impact: Low – Usually, overflowing one of these buffers just causes a segmentation fault of the CGI binary, which causes the web server to return a 502 Bad Gateway error. However the webserver itself is not affected, and no DoS can be achieved. Abusing these buffer overflows in a meaningful way requires highly technical knowledge, especially since ASLR also seems to be enabled on the charging station. However, a skilled attacker might be able to use one of these buffer overflows to obtain remote code execution.
CVSS clarification. The attack can be executed over any network connection the station is listening to and serves the web interface (AV:N), and there are no additional security measure sin place that need to be circumvented (AC:L), the attack does not rely on preconditions (AT:N). The attack does require authentication, but the level of authentication is irrelevant (PR:L), it does not require user interaction (UI:N). The attack has a small impact on the availability of the device (VC:N/VI:N/VA:L). There is no impact on subsequent systems. (SC:N/SI:N/SA:N). While this device is an EV charger handing significant amounts of power, we do not expect this vulnerability to have a safety impact. The attack can be automated (AU:Y). |
| After gaining access to the firmware of a charging station, a file at <redacted> can be accessed to obtain default credentials that are the same across all Iocharger AC model EV chargers.
This issue affects Iocharger firmware for AC models before firmware version 25010801.
The issue is addressed by requiring a mandatory password change on first login, it is still recommended to change the password on older models.
Likelihood: Moderate – The attacker will first have to abuse a code execution or file inclusion vulnerability (for example by using <redacted>.sh) to gain access to the <redacted>.json file, or obtain a firmware dump of the charging station or obtain the firmware via other channels.
Impact: Critical – All chargers using Iocharger firmware for AC models started with the same initial password. For models with firmware version before 25010801 a password change was not mandatory. It is therefore very likely that this firmware password is still active on many chargers. These credentials could, once obtained, allow an attacker to log into many Iocharger charging station, and allow them to execute arbitrary commands via the System → Custom page.
CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, and requires high privileges (PR:H), there is no user interaction required (UI:N). The attack leads to a compromised of the confidentialy of the "super user" credentials of the device (VC:H/VI:N/VA:N), and can subsequently be used to full compromise and other devices (SC:H/SI:H/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y). |
| The <redacted>.so library, which is used by <redacted>, is
vulnerable to a buffer overflow in the code that handles the deletion
of certificates. This buffer overflow can be triggered by providing a
long file path to the <redacted> action of the <redacted>.exe CGI binary or
to the <redacted>.sh CGI script. This binary or script will write this
file path to <redacted>, which is then
read by <redacted>.so
This issue affects Iocharger firmware for AC models before version 24120701.
Likelihood: Moderate – An attacker will have to find this exploit by
either obtaining the binaries involved in this vulnerability, or by trial
and error. Furthermore, the attacker will need a (low privilege)
account to gain access to the <redacted>.exe CGI binary or <redacted>.sh
script to trigger the vulnerability, or convince a user with such access
send an HTTP request that triggers it.
Impact: High – The <redacted> process, which we assume is
responsible for OCPP communication, will keep crashing after
performing the exploit. This happens because the buffer overflow
causes the process to segfault before
<redacted> is removed. This means that,
even though <redacted> is automatically restarted, it will crash
again as soon as it tries to parse the text file.
CVSS clarification. The attack can be executed over any network connection the station is listening to and serves the web interface (AV:N), and there are no additional security measure sin place that need to be circumvented (AC:L), the attack does not rely on preconditions (AT:N). The attack does require authentication, but the level of authentication is irrelevant (PR:L), it does not require user interaction (UI:N). The attack leads to reducred availability of the device (VC:N/VI:N/VA:H). THere is not impact on subsequent systems. (SC:N/SI:N/SA:N). Alltough this device is an EV charger handing significant amounts of power, we do not forsee a safety impact. The attack can be automated (AU:Y). Because the DoS condition is written to disk persistantly, it cannot be recovered by the user (R:I). |
| A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions < V2303), PLUSCONTROL 1st Gen (All versions), SIMOTICS CONNECT 400 (All versions < V0.5.0.0). Malformed TCP packets with a corrupted SACK option leads to Information Leaks and Denial-of-Service conditions. (FSMD-2021-0015) |
| A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions < V2303). When processing a DHCP ACK message, the DHCP client application does not validate the length of the Vendor option(s), leading to Denial-of-Service conditions. (FSMD-2021-0013) |
| A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions < V2303). The DHCP client application does not validate the length of the Domain Name Server IP option(s) (0x06) when processing DHCP ACK packets. This may lead to Denial-of-Service conditions. (FSMD-2021-0011) |
| A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions < V2303). When processing a DHCP OFFER message, the DHCP client application does not validate the length of the Vendor option(s), leading to Denial-of-Service conditions. (FSMD-2021-0008) |
| A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions < V2303), PLUSCONTROL 1st Gen (All versions), SIMOTICS CONNECT 400 (All versions < V0.5.0.0), SIMOTICS CONNECT 400 (All versions < V1.0.0.0). The total length of an ICMP payload (set in the IP header) is unchecked. This may lead to various side effects, including Information Leak and Denial-of-Service conditions, depending on the network buffer organization in memory. (FSMD-2021-0007) |
| A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions < V2303), PLUSCONTROL 1st Gen (All versions). The total length of an UDP payload (set in the IP header) is unchecked. This may lead to various side effects, including Information Leak and Denial-of-Service conditions, depending on a user-defined applications that runs on top of the UDP protocol. (FSMD-2021-0006) |
| MooTools is a collection of JavaScript utilities for JavaScript developers. All known versions include a CSS selector parser that is vulnerable to Regular Expression Denial of Service (ReDoS). An attack requires that an attacker can inject a string into a CSS selector at runtime, which is quite common with e.g. jQuery CSS selectors. No patches are available for this issue. |
| Discourse is an option source discussion platform. Prior to version 2.8.14 on the `stable` branch and version 2.9.0.beta16 on the `beta` and `tests-passed` branches, parsing posts can be susceptible to regular expression denial of service (ReDoS) attacks. This issue is patched in versions 2.8.14 and 2.9.0.beta16. There are no known workarounds. |
| Git is distributed revision control system. `git log` can display commits in an arbitrary format using its `--format` specifiers. This functionality is also exposed to `git archive` via the `export-subst` gitattribute. When processing the padding operators, there is a integer overflow in `pretty.c::format_and_pad_commit()` where a `size_t` is stored improperly as an `int`, and then added as an offset to a `memcpy()`. This overflow can be triggered directly by a user running a command which invokes the commit formatting machinery (e.g., `git log --format=...`). It may also be triggered indirectly through git archive via the export-subst mechanism, which expands format specifiers inside of files within the repository during a git archive. This integer overflow can result in arbitrary heap writes, which may result in arbitrary code execution. The problem has been patched in the versions published on 2023-01-17, going back to v2.30.7. Users are advised to upgrade. Users who are unable to upgrade should disable `git archive` in untrusted repositories. If you expose git archive via `git daemon`, disable it by running `git config --global daemon.uploadArch false`. |
| Sofia-SIP is an open-source SIP User-Agent library, compliant with the IETF RFC3261 specification. In affected versions Sofia-SIP **lacks both message length and attributes length checks** when it handles STUN packets, leading to controllable heap-over-flow. For example, in stun_parse_attribute(), after we get the attribute's type and length value, the length will be used directly to copy from the heap, regardless of the message's left size. Since network users control the overflowed length, and the data is written to heap chunks later, attackers may achieve remote code execution by heap grooming or other exploitation methods. The bug was introduced 16 years ago in sofia-sip 1.12.4 (plus some patches through 12/21/2006) to in tree libs with git-svn-id: http://svn.freeswitch.org/svn/freeswitch/trunk@3774 d0543943-73ff-0310-b7d9-9358b9ac24b2. Users are advised to upgrade. There are no known workarounds for this vulnerability. |
| Redis is an in-memory database that persists on disk. Authenticated users can issue a `HRANDFIELD` or `ZRANDMEMBER` command with specially crafted arguments to trigger a denial-of-service by crashing Redis with an assertion failure. This problem affects Redis versions 6.2 or newer up to but not including 6.2.9 as well as versions 7.0 up to but not including 7.0.8. Users are advised to upgrade. There are no known workarounds for this vulnerability. |