Total
318421 CVE
| CVE | Vendors | Products | Updated | CVSS v3.1 |
|---|---|---|---|---|
| CVE-2025-5318 | 2 Libssh, Redhat | 10 Libssh, Enterprise Linux, Openshift and 7 more | 2025-11-11 | 5.4 Medium |
| A flaw was found in the libssh library in versions less than 0.11.2. An out-of-bounds read can be triggered in the sftp_handle function due to an incorrect comparison check that permits the function to access memory beyond the valid handle list and to return an invalid pointer, which is used in further processing. This vulnerability allows an authenticated remote attacker to potentially read unintended memory regions, exposing sensitive information or affect service behavior. | ||||
| CVE-2025-4945 | 1 Redhat | 1 Enterprise Linux | 2025-11-11 | 3.7 Low |
| A flaw was found in the cookie parsing logic of the libsoup HTTP library, used in GNOME applications and other software. The vulnerability arises when processing the expiration date of cookies, where a specially crafted value can trigger an integer overflow. This may result in undefined behavior, allowing an attacker to bypass cookie expiration logic, causing persistent or unintended cookie behavior. The issue stems from improper validation of large integer inputs during date arithmetic operations within the cookie parsing routines. | ||||
| CVE-2025-40571 | 2025-11-11 | 2.2 Low | ||
| A vulnerability has been identified in Mendix OIDC SSO (Mendix 10 compatible) (All versions < V4.1.0), Mendix OIDC SSO (Mendix 10.12 compatible) (All versions < V4.0.1), Mendix OIDC SSO (Mendix 9 compatible) (All versions < V3.3.0). The Mendix OIDC SSO module grants read and write access to all tokens exclusively to the Administrator role and could result in privilege misuse by an adversary modifying the module during Mendix development. | ||||
| CVE-2025-11021 | 1 Redhat | 1 Enterprise Linux | 2025-11-11 | 7.5 High |
| A flaw was found in the cookie date handling logic of the libsoup HTTP library, widely used by GNOME and other applications for web communication. When processing cookies with specially crafted expiration dates, the library may perform an out-of-bounds memory read. This flaw could result in unintended disclosure of memory contents, potentially exposing sensitive information from the process using libsoup. | ||||
| CVE-2024-56182 | 2025-11-11 | 8.2 High | ||
| A vulnerability has been identified in SIMATIC Field PG M5 (All versions), SIMATIC Field PG M6 (All versions < V26.01.12), SIMATIC IPC BX-21A (All versions < V31.01.07), SIMATIC IPC BX-32A (All versions < V29.01.07), SIMATIC IPC BX-39A (All versions < V29.01.07), SIMATIC IPC BX-59A (All versions < V32.01.04), SIMATIC IPC PX-32A (All versions < V29.01.07), SIMATIC IPC PX-39A (All versions < V29.01.07), SIMATIC IPC PX-39A PRO (All versions < V29.01.07), SIMATIC IPC RC-543A (All versions), SIMATIC IPC RC-543B (All versions), SIMATIC IPC RW-543A (All versions), SIMATIC IPC RW-543B (All versions), SIMATIC IPC127E (All versions), SIMATIC IPC227E (All versions), SIMATIC IPC227G (All versions < V28.01.14), SIMATIC IPC277E (All versions), SIMATIC IPC277G (All versions < V28.01.14), SIMATICÂ IPC277G PRO (All versions < V28.01.14), SIMATIC IPC3000 SMART V3 (All versions), SIMATIC IPC327G (All versions < V28.01.14), SIMATIC IPC347G (All versions), SIMATIC IPC377G (All versions < V28.01.14), SIMATIC IPC427E (All versions), SIMATIC IPC477E (All versions), SIMATIC IPC477E PRO (All versions), SIMATIC IPC527G (All versions), SIMATIC IPC627E (All versions < V25.02.15), SIMATIC IPC647E (All versions < V25.02.15), SIMATIC IPC677E (All versions < V25.02.15), SIMATIC IPC847E (All versions < V25.02.15), SIMATIC ITP1000 (All versions). The affected devices have insufficient protection mechanism for the EFI(Extensible Firmware Interface) variables stored on the device. This could allow an authenticated attacker to disable the BIOS password without proper authorization by directly communicate with the flash controller. | ||||
| CVE-2024-56181 | 2025-11-11 | 8.2 High | ||
| A vulnerability has been identified in SIMATIC Field PG M5 (All versions), SIMATIC IPC BX-21A (All versions < V31.01.07), SIMATIC IPC BX-32A (All versions < V29.01.07), SIMATIC IPC BX-39A (All versions < V29.01.07), SIMATIC IPC BX-59A (All versions < V32.01.04), SIMATIC IPC PX-32A (All versions < V29.01.07), SIMATIC IPC PX-39A (All versions < V29.01.07), SIMATIC IPC PX-39A PRO (All versions < V29.01.07), SIMATIC IPC RC-543A (All versions), SIMATIC IPC RC-543B (All versions), SIMATIC IPC RW-543A (All versions), SIMATIC IPC RW-543B (All versions), SIMATIC IPC127E (All versions), SIMATIC IPC227E (All versions), SIMATIC IPC227G (All versions < V28.01.14), SIMATIC IPC277E (All versions), SIMATIC IPC277G (All versions < V28.01.14), SIMATICÂ IPC277G PRO (All versions < V28.01.14), SIMATIC IPC3000 SMART V3 (All versions), SIMATIC IPC327G (All versions < V28.01.14), SIMATIC IPC347G (All versions), SIMATIC IPC377G (All versions < V28.01.14), SIMATIC IPC427E (All versions), SIMATIC IPC477E (All versions), SIMATIC IPC477E PRO (All versions), SIMATIC IPC527G (All versions), SIMATIC IPC627E (All versions < V25.02.15), SIMATIC IPC647E (All versions < V25.02.15), SIMATIC IPC677E (All versions < V25.02.15), SIMATIC IPC847E (All versions < V25.02.15), SIMATIC ITP1000 (All versions). The affected devices have insufficient protection mechanism for the EFI(Extensible Firmware Interface) variables stored on the device. This could allow an authenticated attacker to alter the secure boot configuration without proper authorization by directly communicate with the flash controller. | ||||
| CVE-2024-53649 | 2025-11-11 | 6.5 Medium | ||
| A vulnerability has been identified in SIPROTEC 5 6MD84 (CP300) (All versions < V9.80), SIPROTEC 5 6MD85 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 6MD86 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 6MD89 (CP300) (All versions >= V7.80 < V9.68), SIPROTEC 5 6MU85 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7KE85 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7SA82 (CP100) (All versions >= V7.80 < V8.90), SIPROTEC 5 7SA82 (CP150) (All versions < V9.80), SIPROTEC 5 7SA86 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7SA87 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7SD82 (CP100) (All versions >= V7.80 < V8.90), SIPROTEC 5 7SD82 (CP150) (All versions < V9.80), SIPROTEC 5 7SD86 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7SD87 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7SJ81 (CP100) (All versions >= V7.80 < V8.90), SIPROTEC 5 7SJ81 (CP150) (All versions < V9.80), SIPROTEC 5 7SJ82 (CP100) (All versions >= V7.80 < V8.90), SIPROTEC 5 7SJ82 (CP150) (All versions < V9.80), SIPROTEC 5 7SJ85 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7SJ86 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7SK82 (CP100) (All versions >= V7.80 < V8.90), SIPROTEC 5 7SK82 (CP150) (All versions < V9.80), SIPROTEC 5 7SK85 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7SL82 (CP100) (All versions >= V7.80 < V8.90), SIPROTEC 5 7SL82 (CP150) (All versions < V9.80), SIPROTEC 5 7SL86 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7SL87 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7SS85 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7ST85 (CP300) (All versions < V9.68), SIPROTEC 5 7ST86 (CP300) (All versions < V9.80), SIPROTEC 5 7SX82 (CP150) (All versions < V9.80), SIPROTEC 5 7SX85 (CP300) (All versions < V9.80), SIPROTEC 5 7SY82 (CP150) (All versions < V9.80), SIPROTEC 5 7UM85 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7UT82 (CP100) (All versions >= V7.80 < V8.90), SIPROTEC 5 7UT82 (CP150) (All versions < V9.80), SIPROTEC 5 7UT85 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7UT86 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7UT87 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7VE85 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7VK87 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7VU85 (CP300) (All versions < V9.80), SIPROTEC 5 Compact 7SX800 (CP050) (All versions < V9.80). Affected devices do not properly limit the path accessible via their webserver. This could allow an authenticated remote attacker to read arbitrary files from the filesystem of affected devices. | ||||
| CVE-2024-53648 | 2025-11-11 | 6.8 Medium | ||
| A vulnerability has been identified in SIPROTEC 5 6MD84 (CP300) (All versions < V9.90), SIPROTEC 5 6MD85 (CP200) (All versions), SIPROTEC 5 6MD85 (CP300) (All versions < V9.90), SIPROTEC 5 6MD86 (CP200) (All versions), SIPROTEC 5 6MD86 (CP300) (All versions < V9.90), SIPROTEC 5 6MD89 (CP300) (All versions < V9.90), SIPROTEC 5 6MU85 (CP300) (All versions < V9.90), SIPROTEC 5 7KE85 (CP200) (All versions), SIPROTEC 5 7KE85 (CP300) (All versions < V10.0), SIPROTEC 5 7SA82 (CP100) (All versions < V8.90), SIPROTEC 5 7SA82 (CP150) (All versions < V9.90), SIPROTEC 5 7SA86 (CP200) (All versions), SIPROTEC 5 7SA86 (CP300) (All versions < V9.90), SIPROTEC 5 7SA87 (CP200) (All versions), SIPROTEC 5 7SA87 (CP300) (All versions < V9.90), SIPROTEC 5 7SD82 (CP100) (All versions < V8.90), SIPROTEC 5 7SD82 (CP150) (All versions < V9.90), SIPROTEC 5 7SD86 (CP200) (All versions), SIPROTEC 5 7SD86 (CP300) (All versions < V9.90), SIPROTEC 5 7SD87 (CP200) (All versions), SIPROTEC 5 7SD87 (CP300) (All versions < V9.90), SIPROTEC 5 7SJ81 (CP100) (All versions < V8.90), SIPROTEC 5 7SJ81 (CP150) (All versions < V9.90), SIPROTEC 5 7SJ82 (CP100) (All versions < V8.90), SIPROTEC 5 7SJ82 (CP150) (All versions < V9.90), SIPROTEC 5 7SJ85 (CP200) (All versions), SIPROTEC 5 7SJ85 (CP300) (All versions < V9.90), SIPROTEC 5 7SJ86 (CP200) (All versions), SIPROTEC 5 7SJ86 (CP300) (All versions < V9.90), SIPROTEC 5 7SK82 (CP100) (All versions < V8.90), SIPROTEC 5 7SK82 (CP150) (All versions < V9.90), SIPROTEC 5 7SK85 (CP200) (All versions), SIPROTEC 5 7SK85 (CP300) (All versions < V9.90), SIPROTEC 5 7SL82 (CP100) (All versions < V8.90), SIPROTEC 5 7SL82 (CP150) (All versions < V9.90), SIPROTEC 5 7SL86 (CP200) (All versions), SIPROTEC 5 7SL86 (CP300) (All versions < V9.90), SIPROTEC 5 7SL87 (CP200) (All versions), SIPROTEC 5 7SL87 (CP300) (All versions < V9.90), SIPROTEC 5 7SS85 (CP200) (All versions), SIPROTEC 5 7SS85 (CP300) (All versions < V9.90), SIPROTEC 5 7ST85 (CP200) (All versions), SIPROTEC 5 7ST85 (CP300) (All versions < V10.0), SIPROTEC 5 7ST86 (CP300) (All versions < V10.0), SIPROTEC 5 7SX82 (CP150) (All versions < V9.90), SIPROTEC 5 7SX85 (CP300) (All versions < V9.90), SIPROTEC 5 7SY82 (CP150) (All versions < V9.90), SIPROTEC 5 7UM85 (CP300) (All versions < V9.90), SIPROTEC 5 7UT82 (CP100) (All versions < V8.90), SIPROTEC 5 7UT82 (CP150) (All versions < V9.90), SIPROTEC 5 7UT85 (CP200) (All versions), SIPROTEC 5 7UT85 (CP300) (All versions < V9.90), SIPROTEC 5 7UT86 (CP200) (All versions), SIPROTEC 5 7UT86 (CP300) (All versions < V9.90), SIPROTEC 5 7UT87 (CP200) (All versions), SIPROTEC 5 7UT87 (CP300) (All versions < V9.90), SIPROTEC 5 7VE85 (CP300) (All versions < V9.90), SIPROTEC 5 7VK87 (CP200) (All versions), SIPROTEC 5 7VK87 (CP300) (All versions < V9.90), SIPROTEC 5 7VU85 (CP300) (All versions < V9.90), SIPROTEC 5 Compact 7SX800 (CP050) (All versions < V9.90). Affected devices do not properly limit access to a development shell accessible over a physical interface. This could allow an unauthenticated attacker with physical access to the device to execute arbitrary commands on the device. | ||||
| CVE-2024-38867 | 2025-11-11 | 5.9 Medium | ||
| A vulnerability has been identified in SIPROTEC 5 6MD84 (CP300) (All versions < V9.64), SIPROTEC 5 6MD85 (CP200) (All versions), SIPROTEC 5 6MD85 (CP300) (All versions < V9.64), SIPROTEC 5 6MD86 (CP200) (All versions), SIPROTEC 5 6MD86 (CP300) (All versions < V9.64), SIPROTEC 5 6MD89 (CP300) (All versions < V9.64), SIPROTEC 5 6MU85 (CP300) (All versions < V9.64), SIPROTEC 5 7KE85 (CP200) (All versions), SIPROTEC 5 7KE85 (CP300) (All versions < V9.64), SIPROTEC 5 7SA82 (CP100) (All versions < V8.90), SIPROTEC 5 7SA82 (CP150) (All versions < V9.65), SIPROTEC 5 7SA84 (CP200) (All versions), SIPROTEC 5 7SA86 (CP200) (All versions), SIPROTEC 5 7SA86 (CP300) (All versions < V9.65), SIPROTEC 5 7SA87 (CP200) (All versions), SIPROTEC 5 7SA87 (CP300) (All versions < V9.65), SIPROTEC 5 7SD82 (CP100) (All versions < V8.90), SIPROTEC 5 7SD82 (CP150) (All versions < V9.65), SIPROTEC 5 7SD84 (CP200) (All versions), SIPROTEC 5 7SD86 (CP200) (All versions), SIPROTEC 5 7SD86 (CP300) (All versions < V9.65), SIPROTEC 5 7SD87 (CP200) (All versions), SIPROTEC 5 7SD87 (CP300) (All versions < V9.65), SIPROTEC 5 7SJ81 (CP100) (All versions < V8.89), SIPROTEC 5 7SJ81 (CP150) (All versions < V9.65), SIPROTEC 5 7SJ82 (CP100) (All versions < V8.89), SIPROTEC 5 7SJ82 (CP150) (All versions < V9.65), SIPROTEC 5 7SJ85 (CP200) (All versions), SIPROTEC 5 7SJ85 (CP300) (All versions < V9.65), SIPROTEC 5 7SJ86 (CP200) (All versions), SIPROTEC 5 7SJ86 (CP300) (All versions < V9.65), SIPROTEC 5 7SK82 (CP100) (All versions < V8.89), SIPROTEC 5 7SK82 (CP150) (All versions < V9.65), SIPROTEC 5 7SK85 (CP200) (All versions), SIPROTEC 5 7SK85 (CP300) (All versions < V9.65), SIPROTEC 5 7SL82 (CP100) (All versions < V8.90), SIPROTEC 5 7SL82 (CP150) (All versions < V9.65), SIPROTEC 5 7SL86 (CP200) (All versions), SIPROTEC 5 7SL86 (CP300) (All versions < V9.65), SIPROTEC 5 7SL87 (CP200) (All versions), SIPROTEC 5 7SL87 (CP300) (All versions < V9.65), SIPROTEC 5 7SS85 (CP200) (All versions), SIPROTEC 5 7SS85 (CP300) (All versions < V9.64), SIPROTEC 5 7ST85 (CP200) (All versions), SIPROTEC 5 7ST85 (CP300) (All versions < V9.64), SIPROTEC 5 7ST86 (CP300) (All versions < V9.64), SIPROTEC 5 7SX82 (CP150) (All versions < V9.65), SIPROTEC 5 7SX85 (CP300) (All versions < V9.65), SIPROTEC 5 7UM85 (CP300) (All versions < V9.64), SIPROTEC 5 7UT82 (CP100) (All versions < V8.90), SIPROTEC 5 7UT82 (CP150) (All versions < V9.65), SIPROTEC 5 7UT85 (CP200) (All versions), SIPROTEC 5 7UT85 (CP300) (All versions < V9.65), SIPROTEC 5 7UT86 (CP200) (All versions), SIPROTEC 5 7UT86 (CP300) (All versions < V9.65), SIPROTEC 5 7UT87 (CP200) (All versions), SIPROTEC 5 7UT87 (CP300) (All versions < V9.65), SIPROTEC 5 7VE85 (CP300) (All versions < V9.64), SIPROTEC 5 7VK87 (CP200) (All versions), SIPROTEC 5 7VK87 (CP300) (All versions < V9.65), SIPROTEC 5 7VU85 (CP300) (All versions < V9.64), SIPROTEC 5 Communication Module ETH-BA-2EL (Rev.1) (All versions < V9.62 installed on CP150 and CP300 devices), SIPROTEC 5 Communication Module ETH-BA-2EL (Rev.1) (All versions installed on CP200 devices), SIPROTEC 5 Communication Module ETH-BA-2EL (Rev.1) (All versions < V8.89 installed on CP100 devices), SIPROTEC 5 Communication Module ETH-BB-2FO (Rev. 1) (All versions installed on CP200 devices), SIPROTEC 5 Communication Module ETH-BB-2FO (Rev. 1) (All versions < V9.62 installed on CP150 and CP300 devices), SIPROTEC 5 Communication Module ETH-BB-2FO (Rev. 1) (All versions < V8.89 installed on CP100 devices), SIPROTEC 5 Communication Module ETH-BD-2FO (All versions < V9.62), SIPROTEC 5 Compact 7SX800 (CP050) (All versions < V9.64). The affected devices are supporting weak ciphers on several ports (443/tcp for web, 4443/tcp for DIGSI 5 and configurable port for syslog over TLS). This could allow an unauthorized attacker in a man-in-the-middle position to decrypt any data passed over to and from those ports. | ||||
| CVE-2023-31238 | 1 Siemens | 2 Q200, Q200 Firmware | 2025-11-11 | 5.5 Medium |
| A vulnerability has been identified in SICAM P850 (7KG8500-0AA00-0AA0) (All versions < V3.11), SICAM P850 (7KG8500-0AA00-2AA0) (All versions < V3.11), SICAM P850 (7KG8500-0AA10-0AA0) (All versions < V3.11), SICAM P850 (7KG8500-0AA10-2AA0) (All versions < V3.11), SICAM P850 (7KG8500-0AA30-0AA0) (All versions < V3.11), SICAM P850 (7KG8500-0AA30-2AA0) (All versions < V3.11), SICAM P850 (7KG8501-0AA01-0AA0) (All versions < V3.11), SICAM P850 (7KG8501-0AA01-2AA0) (All versions < V3.11), SICAM P850 (7KG8501-0AA02-0AA0) (All versions < V3.11), SICAM P850 (7KG8501-0AA02-2AA0) (All versions < V3.11), SICAM P850 (7KG8501-0AA11-0AA0) (All versions < V3.11), SICAM P850 (7KG8501-0AA11-2AA0) (All versions < V3.11), SICAM P850 (7KG8501-0AA12-0AA0) (All versions < V3.11), SICAM P850 (7KG8501-0AA12-2AA0) (All versions < V3.11), SICAM P850 (7KG8501-0AA31-0AA0) (All versions < V3.11), SICAM P850 (7KG8501-0AA31-2AA0) (All versions < V3.11), SICAM P850 (7KG8501-0AA32-0AA0) (All versions < V3.11), SICAM P850 (7KG8501-0AA32-2AA0) (All versions < V3.11), SICAM P855 (7KG8550-0AA00-0AA0) (All versions < V3.11), SICAM P855 (7KG8550-0AA00-2AA0) (All versions < V3.11), SICAM P855 (7KG8550-0AA10-0AA0) (All versions < V3.11), SICAM P855 (7KG8550-0AA10-2AA0) (All versions < V3.11), SICAM P855 (7KG8550-0AA30-0AA0) (All versions < V3.11), SICAM P855 (7KG8550-0AA30-2AA0) (All versions < V3.11), SICAM P855 (7KG8551-0AA01-0AA0) (All versions < V3.11), SICAM P855 (7KG8551-0AA01-2AA0) (All versions < V3.11), SICAM P855 (7KG8551-0AA02-0AA0) (All versions < V3.11), SICAM P855 (7KG8551-0AA02-2AA0) (All versions < V3.11), SICAM P855 (7KG8551-0AA11-0AA0) (All versions < V3.11), SICAM P855 (7KG8551-0AA11-2AA0) (All versions < V3.11), SICAM P855 (7KG8551-0AA12-0AA0) (All versions < V3.11), SICAM P855 (7KG8551-0AA12-2AA0) (All versions < V3.11), SICAM P855 (7KG8551-0AA31-0AA0) (All versions < V3.11), SICAM P855 (7KG8551-0AA31-2AA0) (All versions < V3.11), SICAM P855 (7KG8551-0AA32-0AA0) (All versions < V3.11), SICAM P855 (7KG8551-0AA32-2AA0) (All versions < V3.11). Affected devices are missing cookie protection flags when using the default settings. An attacker who gains access to a session token can use it to impersonate a legitimate application user. | ||||
| CVE-2023-30901 | 1 Siemens | 2 Q200, Q200 Firmware | 2025-11-11 | 4.3 Medium |
| A vulnerability has been identified in SICAM P850 (7KG8500-0AA00-0AA0) (All versions < V3.11), SICAM P850 (7KG8500-0AA00-2AA0) (All versions < V3.11), SICAM P850 (7KG8500-0AA10-0AA0) (All versions < V3.11), SICAM P850 (7KG8500-0AA10-2AA0) (All versions < V3.11), SICAM P850 (7KG8500-0AA30-0AA0) (All versions < V3.11), SICAM P850 (7KG8500-0AA30-2AA0) (All versions < V3.11), SICAM P850 (7KG8501-0AA01-0AA0) (All versions < V3.11), SICAM P850 (7KG8501-0AA01-2AA0) (All versions < V3.11), SICAM P850 (7KG8501-0AA02-0AA0) (All versions < V3.11), SICAM P850 (7KG8501-0AA02-2AA0) (All versions < V3.11), SICAM P850 (7KG8501-0AA11-0AA0) (All versions < V3.11), SICAM P850 (7KG8501-0AA11-2AA0) (All versions < V3.11), SICAM P850 (7KG8501-0AA12-0AA0) (All versions < V3.11), SICAM P850 (7KG8501-0AA12-2AA0) (All versions < V3.11), SICAM P850 (7KG8501-0AA31-0AA0) (All versions < V3.11), SICAM P850 (7KG8501-0AA31-2AA0) (All versions < V3.11), SICAM P850 (7KG8501-0AA32-0AA0) (All versions < V3.11), SICAM P850 (7KG8501-0AA32-2AA0) (All versions < V3.11), SICAM P855 (7KG8550-0AA00-0AA0) (All versions < V3.11), SICAM P855 (7KG8550-0AA00-2AA0) (All versions < V3.11), SICAM P855 (7KG8550-0AA10-0AA0) (All versions < V3.11), SICAM P855 (7KG8550-0AA10-2AA0) (All versions < V3.11), SICAM P855 (7KG8550-0AA30-0AA0) (All versions < V3.11), SICAM P855 (7KG8550-0AA30-2AA0) (All versions < V3.11), SICAM P855 (7KG8551-0AA01-0AA0) (All versions < V3.11), SICAM P855 (7KG8551-0AA01-2AA0) (All versions < V3.11), SICAM P855 (7KG8551-0AA02-0AA0) (All versions < V3.11), SICAM P855 (7KG8551-0AA02-2AA0) (All versions < V3.11), SICAM P855 (7KG8551-0AA11-0AA0) (All versions < V3.11), SICAM P855 (7KG8551-0AA11-2AA0) (All versions < V3.11), SICAM P855 (7KG8551-0AA12-0AA0) (All versions < V3.11), SICAM P855 (7KG8551-0AA12-2AA0) (All versions < V3.11), SICAM P855 (7KG8551-0AA31-0AA0) (All versions < V3.11), SICAM P855 (7KG8551-0AA31-2AA0) (All versions < V3.11), SICAM P855 (7KG8551-0AA32-0AA0) (All versions < V3.11), SICAM P855 (7KG8551-0AA32-2AA0) (All versions < V3.11). The web interface of the affected devices are vulnerable to Cross-Site Request Forgery attacks. By tricking an authenticated victim user to click a malicious link, an attacker could perform arbitrary actions on the device on behalf of the victim user. | ||||
| CVE-2023-28766 | 1 Siemens | 78 Siprotec 5 6md85, Siprotec 5 6md85 Firmware, Siprotec 5 6md86 and 75 more | 2025-11-11 | 7.5 High |
| A vulnerability has been identified in SIPROTEC 5 6MD85 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 6MD86 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 6MD89 (CP300) (All versions >= V7.80 < V9.64), SIPROTEC 5 6MU85 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7KE85 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7SA82 (CP100) (All versions < V8.90), SIPROTEC 5 7SA82 (CP150) (All versions < V9.40), SIPROTEC 5 7SA86 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7SA87 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7SD82 (CP100) (All versions < V8.90), SIPROTEC 5 7SD82 (CP150) (All versions < V9.40), SIPROTEC 5 7SD86 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7SD87 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7SJ81 (CP100) (All versions < V8.89), SIPROTEC 5 7SJ81 (CP150) (All versions < V9.40), SIPROTEC 5 7SJ82 (CP100) (All versions < V8.89), SIPROTEC 5 7SJ82 (CP150) (All versions < V9.40), SIPROTEC 5 7SJ85 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7SJ86 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7SK82 (CP100) (All versions < V8.89), SIPROTEC 5 7SK82 (CP150) (All versions < V9.40), SIPROTEC 5 7SK85 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7SL82 (CP100) (All versions < V8.90), SIPROTEC 5 7SL82 (CP150) (All versions < V9.40), SIPROTEC 5 7SL86 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7SL87 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7SS85 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7ST85 (CP300) (All versions >= V7.80 < V9.64), SIPROTEC 5 7ST86 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7SX82 (CP150) (All versions < V9.40), SIPROTEC 5 7SX85 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7UM85 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7UT82 (CP100) (All versions < V8.90), SIPROTEC 5 7UT82 (CP150) (All versions < V9.40), SIPROTEC 5 7UT85 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7UT86 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7UT87 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7VE85 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7VK87 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7VU85 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 Communication Module ETH-BA-2EL (Rev.1) (All versions < V9.40 installed on CP150 and CP300 devices), SIPROTEC 5 Communication Module ETH-BA-2EL (Rev.1) (All versions < V8.89 installed on CP100 devices), SIPROTEC 5 Communication Module ETH-BB-2FO (Rev. 1) (All versions < V9.40 installed on CP150 and CP300 devices), SIPROTEC 5 Communication Module ETH-BB-2FO (Rev. 1) (All versions < V8.89 installed on CP100 devices), SIPROTEC 5 Communication Module ETH-BD-2FO (All versions < V9.40), SIPROTEC 5 Compact 7SX800 (CP050) (All versions < V9.40). Affected devices lack proper validation of http request parameters of the hosted web service. An unauthenticated remote attacker could send specially crafted packets that could cause denial of service condition of the target device. | ||||
| CVE-2022-45044 | 1 Siemens | 68 Siprotec 5 6md85, Siprotec 5 6md85 Firmware, Siprotec 5 6md86 and 65 more | 2025-11-11 | 5.3 Medium |
| A vulnerability has been identified in SIPROTEC 5 6MD84 (CP300) (All versions < V9.50), SIPROTEC 5 6MD85 (CP200) (All versions), SIPROTEC 5 6MD85 (CP300) (All versions < V9.50), SIPROTEC 5 6MD86 (CP200) (All versions), SIPROTEC 5 6MD86 (CP300) (All versions < V9.50), SIPROTEC 5 6MD89 (CP300) (All versions < V9.64), SIPROTEC 5 6MU85 (CP300) (All versions < V9.50), SIPROTEC 5 7KE85 (CP200) (All versions), SIPROTEC 5 7KE85 (CP300) (All versions < V9.64), SIPROTEC 5 7SA82 (CP100) (All versions < V8.90), SIPROTEC 5 7SA82 (CP150) (All versions < V9.50), SIPROTEC 5 7SA84 (CP200) (All versions), SIPROTEC 5 7SA86 (CP200) (All versions), SIPROTEC 5 7SA86 (CP300) (All versions < V9.50), SIPROTEC 5 7SA87 (CP200) (All versions), SIPROTEC 5 7SA87 (CP300) (All versions < V9.50), SIPROTEC 5 7SD82 (CP100) (All versions < V8.90), SIPROTEC 5 7SD82 (CP150) (All versions < V9.50), SIPROTEC 5 7SD84 (CP200) (All versions), SIPROTEC 5 7SD86 (CP200) (All versions), SIPROTEC 5 7SD86 (CP300) (All versions < V9.50), SIPROTEC 5 7SD87 (CP200) (All versions), SIPROTEC 5 7SD87 (CP300) (All versions < V9.50), SIPROTEC 5 7SJ81 (CP100) (All versions < V8.89), SIPROTEC 5 7SJ81 (CP150) (All versions < V9.50), SIPROTEC 5 7SJ82 (CP100) (All versions < V8.89), SIPROTEC 5 7SJ82 (CP150) (All versions < V9.50), SIPROTEC 5 7SJ85 (CP200) (All versions), SIPROTEC 5 7SJ85 (CP300) (All versions < V9.50), SIPROTEC 5 7SJ86 (CP200) (All versions), SIPROTEC 5 7SJ86 (CP300) (All versions < V9.50), SIPROTEC 5 7SK82 (CP100) (All versions < V8.89), SIPROTEC 5 7SK82 (CP150) (All versions < V9.50), SIPROTEC 5 7SK85 (CP200) (All versions), SIPROTEC 5 7SK85 (CP300) (All versions < V9.50), SIPROTEC 5 7SL82 (CP100) (All versions < V8.90), SIPROTEC 5 7SL82 (CP150) (All versions < V9.50), SIPROTEC 5 7SL86 (CP200) (All versions), SIPROTEC 5 7SL86 (CP300) (All versions < V9.50), SIPROTEC 5 7SL87 (CP200) (All versions), SIPROTEC 5 7SL87 (CP300) (All versions < V9.50), SIPROTEC 5 7SS85 (CP200) (All versions), SIPROTEC 5 7SS85 (CP300) (All versions < V9.50), SIPROTEC 5 7ST85 (CP200) (All versions), SIPROTEC 5 7ST85 (CP300) (All versions < V9.64), SIPROTEC 5 7ST86 (CP300) (All versions < V9.64), SIPROTEC 5 7SX82 (CP150) (All versions < V9.50), SIPROTEC 5 7SX85 (CP300) (All versions < V9.50), SIPROTEC 5 7UM85 (CP300) (All versions < V9.50), SIPROTEC 5 7UT82 (CP100) (All versions < V8.90), SIPROTEC 5 7UT82 (CP150) (All versions < V9.50), SIPROTEC 5 7UT85 (CP200) (All versions), SIPROTEC 5 7UT85 (CP300) (All versions < V9.50), SIPROTEC 5 7UT86 (CP200) (All versions), SIPROTEC 5 7UT86 (CP300) (All versions < V9.50), SIPROTEC 5 7UT87 (CP200) (All versions), SIPROTEC 5 7UT87 (CP300) (All versions < V9.50), SIPROTEC 5 7VE85 (CP300) (All versions < V9.50), SIPROTEC 5 7VK87 (CP200) (All versions), SIPROTEC 5 7VK87 (CP300) (All versions < V9.50), SIPROTEC 5 7VU85 (CP300) (All versions < V9.50), SIPROTEC 5 Communication Module ETH-BA-2EL (Rev.1) (All versions installed on CP200 devices), SIPROTEC 5 Communication Module ETH-BA-2EL (Rev.1) (All versions < V9.50 installed on CP150 and CP300 devices), SIPROTEC 5 Communication Module ETH-BA-2EL (Rev.1) (All versions < V8.89 installed on CP100 devices), SIPROTEC 5 Communication Module ETH-BB-2FO (Rev. 1) (All versions installed on CP200 devices), SIPROTEC 5 Communication Module ETH-BB-2FO (Rev. 1) (All versions < V9.50 installed on CP150 and CP300 devices), SIPROTEC 5 Communication Module ETH-BB-2FO (Rev. 1) (All versions < V8.89 installed on CP100 devices), SIPROTEC 5 Communication Module ETH-BD-2FO (All versions < V9.50), SIPROTEC 5 Compact 7SX800 (CP050) (All versions < V9.50). Affected devices do not properly restrict secure client-initiated renegotiations within the SSL and TLS protocols. This could allow an attacker to create a denial of service condition on the ports 443/tcp and 4443/tcp for the duration of the attack. | ||||
| CVE-2025-30033 | 2025-11-11 | 7.8 High | ||
| The affected setup component is vulnerable to DLL hijacking. This could allow an attacker to execute arbitrary code when a legitimate user installs an application that uses the affected setup component. | ||||
| CVE-2023-28831 | 1 Siemens | 156 Simatic Cloud Connect 7 Cc712, Simatic Cloud Connect 7 Cc712 Firmware, Simatic Cloud Connect 7 Cc716 and 153 more | 2025-11-11 | 7.5 High |
| The OPC UA implementations (ANSI C and C++) in affected products contain an integer overflow vulnerability that could cause the application to run into an infinite loop during certificate validation. This could allow an unauthenticated remote attacker to create a denial of service condition by sending a specially crafted certificate. | ||||
| CVE-2023-4813 | 4 Fedoraproject, Gnu, Netapp and 1 more | 23 Fedora, Glibc, Active Iq Unified Manager and 20 more | 2025-11-11 | 5.9 Medium |
| A flaw has been identified in glibc. In an uncommon situation, the gaih_inet function may use memory that has been freed, resulting in an application crash. This issue is only exploitable when the getaddrinfo function is called and the hosts database in /etc/nsswitch.conf is configured with SUCCESS=continue or SUCCESS=merge. | ||||
| CVE-2025-56764 | 2 Trivision, Trivisionsecurity | 3 Nc-227wf, Trivision Nc-227wf, Trivision Nc-227wf Firmware | 2025-11-11 | 5.3 Medium |
| Trivision NC-227WF firmware 5.80 (build 20141010) login mechanism reveals whether a username exists or not by returning different error messages ("Unknown user" vs. "Wrong password"), allowing an attacker to enumerate valid usernames. | ||||
| CVE-2025-3146 | 1 Phpgurukul | 1 Bus Pass Management System | 2025-11-11 | 7.3 High |
| A vulnerability, which was classified as critical, was found in PHPGurukul Bus Pass Management System 1.0. This affects an unknown part of the file /view-pass-detail.php. The manipulation of the argument viewid leads to sql injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. | ||||
| CVE-2020-5510 | 1 Phpgurukul | 1 Hostel Management System | 2025-11-11 | 9.8 Critical |
| PHPGurukul Hostel Management System v2.0 allows SQL injection via the id parameter in the full-profile.php file. | ||||
| CVE-2018-11544 | 1 Theolivetree | 1 Ftp Server | 2025-11-11 | 9.8 Critical |
| The Olive Tree Ftp Server application 1.32 for Android has Insecure Data Storage because a username and password are stored in the /data/data/com.theolivetree.ftpserver/shared_prefs/com.theolivetree.ftpserver_preferences.xml file as the prefUsername and prefUserpass strings. | ||||