CVE-2026-78663 1 Go Standard Library 2 Net/http, Net/http2 2026-10-09 9.1 Critical
The HTTP/2 server can refund connection-level flow control twice for the same data: Once when a client resets a stream (refunding data for any sent-but-unread portion of the stream), and again when a request handler reads the buffered data. A malicious client can exploit this to bypass the configured connection-level flow control limit (MaxReceiveBufferPerConnection). Total buffered data is still limited by the concurrent stream limit and stream-level flow control.
CVE-2026-76280 1 Splunk 2 Splunk Enterprise, Splunk Secure Gateway 2026-10-09 6.3 Medium
In Splunk Enterprise versions below 10.4.3, 10.2.7, 10.0.10, and 9.4.15, and Splunk Secure Gateway versions below 3.10.11, 3.9.25, and 3.8.72, an authenticated user who does not hold the "admin" or "sc_admin" Splunk roles could modify Splunk Secure Gateway alert and mobile-device recipient data in App Key Value Store (KV Store) collections that later alert and subscription workflows use. The vulnerability is possible because the affected collections allow unrestricted write access instead of limiting writes to authorized Splunk Secure Gateway workflows. For more information see About the app key value store (https://help.splunk.com/en/splunk-enterprise/administer/admin-manual/10.4/administer-the-app-key-value-store/about-the-app-key-value-store), KV store endpoint descriptions (https://help.splunk.com/en/splunk-enterprise/leverage-rest-apis/rest-api-reference/10.4/kv-store-endpoints/kv-store-endpoint-descriptions), and About configuring role-based user access (https://help.splunk.com/en/splunk-enterprise/administer/manage-users-and-security/10.4/manage-splunk-platform-users-and-roles/about-configuring-role-based-user-access) in the Splunk documentation.
CVE-2026-76275 1 Splunk 1 Splunk Enterprise 2026-10-09 4.3 Medium
In Splunk Enterprise versions below 10.4.3, 10.2.7, 10.0.10, and 9.4.15, a user who does not hold the "admin" or "power" Splunk roles could access search query text and job metadata for jobs that belong to other users, including job identifiers, dispatch parameters, result counts, and execution metadata, through an Application Programming Interface (API) implemented as a Representational State Transfer (REST) API. The vulnerability is possible because the REST API does not fully enforce per-user authorization before it includes job information in search job listings.
CVE-2026-76270 1 Splunk 1 Splunk Enterprise 2026-10-09 6.5 Medium
In Splunk Enterprise versions below 10.4.3, a user that holds a role with the list_spl2_modules capability could use SQL injection in SPL2 module filtering to access all relevant data available through the affected Representational State Transfer (REST) API, including private SPL2 module definitions belonging to other users. The vulnerability is possible because Splunk Enterprise and Splunk Cloud Platform do not parameterize user-supplied values before using them in database queries for SPL2 module filtering. For more information see Manage SPL2 modules (https://help.splunk.com/en/splunk-enterprise/search/spl2-search-manual/multiple-searches-in-an-spl2-module/manage-spl2-modules) and Module permissions (https://help.splunk.com/en/splunk-enterprise/search/spl2-search-manual/modules-statements-and-views/module-permissions) in the Splunk documentation. Splunk Enterprise versions 10.2.x, 10.0.x, and 9.4.x are not affected.
CVE-2026-76265 1 Splunk 2 Splunk Enterprise, Splunk Secure Gateway 2026-10-09 6.5 Medium
In Splunk Enterprise versions below 10.4.3, 10.2.7, 10.0.10, and 9.4.15, and Splunk Secure Gateway versions below 3.10.11, 3.9.25, and 3.8.72, a user who does not hold the "admin" or "power" Splunk roles could access privileged Splunk Secure Gateway functionality. With this access, the user could cause Splunk Secure Gateway to sign attacker-controlled payloads. The vulnerability is possible because multiple Splunk Secure Gateway Representational State Transfer (REST) API endpoints do not enforce authorization requirements before processing requests.
CVE-2026-59523 2 Nsquared, Wordpress 2 Simply Schedule Appointments, Wordpress 2026-10-09 6.5 Medium
Missing Authorization vulnerability in NSquared Simply Schedule Appointments simply-schedule-appointments allows Exploiting Incorrectly Configured Access Control Security Levels.This issue affects Simply Schedule Appointments: from n/a through 1.6.11.11.
CVE-2026-107911 1 Falkordb 1 Falkordb 2026-10-09 7.5 High
A type confusion vulnerability in the _read_flags function (src/commands/cmd_dispatcher.c) in FalkorDB before 4.20.0 allows a remote authenticated attacker who can run GRAPH.QUERY to cause a denial of service and possibly disclose or corrupt memory. The function accepts a --bolt argument from any client and casts the following command argument, a Redis string object, to a Bolt client structure without checking its origin; the result-set code then dereferences pointers read from that object. The argument is parsed even when the Bolt endpoint is disabled, so default configurations are affected.
CVE-2026-107809 1 0xjacky 1 Nginx-ui 2026-10-09 8.8 High
Nginx UI is a web user interface for the Nginx web server. From 2.0.0 until 2.5.0, AuthRequired accepts a browser-managed token cookie as an API credential after the front end stores the JWT in that cookie. Because management endpoints do not universally require a CSRF token or perform Origin or Referer validation, a remote attacker can induce a logged-in administrator's browser to submit authenticated cross-site state-changing requests, including POST /api/configs. The attack requires an administrator account without OTP/Passkey or a target endpoint that does not require secure-session proof. The attacker cannot read the cross-origin response but can modify Nginx configuration, trigger reloads, or invoke other management operations reachable with the victim's session. This issue is fixed in version 2.5.0.
CVE-2026-107785 2026-10-09 N/A
Crux Agent from 1.9.0 before 2.0.3 uses the full SKA bilocation key as the WireGuard preshared key. When a peering session negotiates use of SHA-512, the key produced is 64 bytes instead of the 32 bytes WireGuard requires. The agent does not validate this size; instead it attempts to use the `wg set` command to update the live tunnel, and write the invalid key to the WireGuard configuration file. The update fails, so the live tunnel keeps using its previous preshared key until the tunnel is shut down. The tunnel will fail to start when restarted. For a peer which has never successfully negotiated a 32-byte bilocation key in a Crux C2 organization which has the "Enforce SKA Use" setting turned off, no preshared key will be set for the tunnel. Therefore, an attacker who is able to intercept and store the peer's traffic, and has access (or will have access) to a cryptographically relevant quantum computer, will be able to decrypt the tunnel.
CVE-2026-107332 1 Aws 1 Aws-toolkit-vscode 2026-10-09 5.5 Medium
Insecure file permissions in the CodeCatalyst connection handler in AWS Toolkit for VS Code before 4.10.0 allowed local users to obtain CodeCatalyst bearer tokens via reading world-readable token cache files. To mitigate this issue, users should upgrade to version 4.10.0 or later.
CVE-2026-106581 1 Docker 1 Desktop 2026-10-09 N/A
Before 4.92.0, Docker Desktop for Windows did not verify the signature of a package supplied to Docker Desktop Installer.exe install -package. An attacker able to provide a crafted package and convince a user to approve the Docker-signed UAC prompt could execute attacker-controlled installer actions as LocalSystem.
CVE-2026-104629 2026-10-09 8.8 High
A component loading mechanism in openPDC and openHistorian will construct and run any specified type, which may be an invalid component to load. An attacker with an authenticated user account and the ability to place a file on the host filesystem can use this to run arbitrary constructor code, and this code runs with the privileges of the affected service account.
CVE-2026-104117 2 Illumos, Omnios 2 Illumos-gate, Omnios 2026-10-09 N/A
A missing authorization check in the illumos IP management daemon (ipmgmtd) allows a local user to change the persistent IP multipathing (IPMP) configuration. The ipmgmtd door dispatch table in usr/src/cmd/cmd-inet/lib/ipmgmtd/ipmgmt_door.c does not require the solaris.network.interface.config authorization for the IPMGMT_CMD_IPMP_UPDATE command, although its handler, ipmgmt_ipmp_update_handler(), writes to the persistent ipadm configuration when the IPMGMT_PERSIST flag is set. An unprivileged local user can therefore add interfaces to, or remove them from, existing IPMP groups in the stored configuration. The running configuration is not changed; the modification takes effect when the stored configuration is next applied, such as at boot, and may disrupt network connectivity. The flaw has existed since 2021 (illumos-gate commit a73be61a), and affects any illumos distribution prior to illumos-gate commit e8d3efa1.
CVE-2026-104116 2 Illumos, Omnios 2 Illumos-gate, Omnios 2026-10-09 N/A
A missing authorization check in the illumos zones statistics daemon (zonestatd) allows a local user in any zone to disrupt zonestat in other zones and to determine which zones are running. The zonestatd door server procedure, zsd_server() in usr/src/cmd/zonestat/zonestatd/zonestatd.c, handles the ZSD_CMD_NEW_ZONE command, which is intended to be sent by zoneadmd, without checking the caller's credentials. Because the zonestatd door is accessible to all users in every zone, an unprivileged user can send this command with an arbitrary zone ID, causing zonestatd to re-create its door file in that zone, so that new zonestat requests in that zone can fail while the file is replaced. The time taken to handle the command also reveals whether a given zone ID belongs to a running zone. The flaw has existed since 2010 (illumos-gate commit efd4c9b6), and affects any illumos distribution prior to illumos-gate commit 865b58d2.
CVE-2026-104114 2 Illumos, Omnios 2 Illumos-gate, Omnios 2026-10-09 N/A
A NULL pointer dereference in the illumos Network Auto-Magic daemon (nwamd) allows a local user to crash the daemon. nwamd_door_switch() in usr/src/cmd/cmd-inet/lib/nwamd/door_if.c writes to the caller's request structure before checking that a request was supplied, and before checking the caller's credentials. Because the nwamd door at /etc/svc/volatile/nwam/nwam_door is accessible to all local users, an unprivileged user can issue a door_call() with no argument data to crash nwamd; repeated calls place the svc:/network/physical:nwam service into maintenance, stopping automatic network configuration. nwamd runs only when svc:/network/physical:nwam is enabled, which is not the default. The flaw has existed since 2010 (illumos-gate commit 6ba597c5), and affects any illumos distribution prior to illumos-gate commit 0f1064d9.
CVE-2026-104113 1 Omnios 1 Omnios 2026-10-09 N/A
A double free in the IP management daemon (ipmgmtd) of OmniOS and SmartOS allows a local user to crash the daemon. When authorizing a door request that modifies interface configuration, ipmgmt_handler() in usr/src/cmd/cmd-inet/lib/ipmgmtd/ipmgmt_door.c frees the caller's credential with ucred_free() immediately after reading the user ID, and frees it a second time on the error path if the authorization check fails. An unprivileged local user who does not hold the solaris.network.interface.config authorization can send such a request, for example IPMGMT_CMD_RESETIF, to the ipmgmtd door, causing ipmgmtd to abort; repeated requests place the svc:/network/ip-interface-management service into maintenance, preventing IP interface configuration. The early free was introduced in 2014 to support lx-branded zones (OmniOS commit 4c170900) and is not present in upstream illumos-gate. It affects OmniOS r151020 and later, and SmartOS, prior to the fix.
CVE-2026-104112 2 Illumos, Omnios 2 Illumos-gate, Omnios 2026-10-09 N/A
A missing release of resources in the illumos name service cache daemon (nscd) allows a local user to exhaust kernel memory. The nscd door server procedure, switcher() in usr/src/cmd/nscd/nscd_frontend.c, does not close file descriptors that are passed with a door call but not used by the request, and the main nscd door at /var/run/name_service_door accepts passed descriptors from any user in its zone. Because nscd also runs with an unlimited file descriptor limit, an unprivileged local user, including one in a non-global zone, can repeatedly pass a descriptor to its zone's nscd in a door_call() loop, causing the file descriptor table of nscd to grow without bound in kernel memory. This causes a denial of service of nscd and can render processes in all zones on the host unresponsive. The flaw has existed since 2006 (illumos-gate commit cb5caa98), and affects any illumos distribution prior to illumos-gate commit af810a72.
CVE-2026-103220 1 Canva 1 Affinity 2026-10-09 4.5 Medium
The Affinity by Canva application before 3.3.1 (October 2026 release) did not perform adequate bounds checking when parsing raster image data in Affinity document files, leading to an out-of-bounds read and the dereference of an untrusted pointer. A threat actor could craft an Affinity document that, when opened by a user in Affinity, could result in memory corruption or an application crash.
CVE-2026-102916 2 Illumos, Omnios 2 Illumos-gate, Omnios 2026-10-09 N/A
A reachable assertion in the illumos bhyve instruction emulator allows a guest to panic the host. When emulating a REP-prefixed MOVS or STOS instruction that accesses guest MMIO, vie_emulate_movs() and vie_emulate_stos() in usr/src/uts/intel/io/vmm/vmm_instruction_emul.c do not clear the VIES_REPEAT status flag on the final iteration. For MMIO regions emulated in the kernel (the local APIC, I/O APIC and HPET), the stale flag causes a VERIFY assertion in vie_advance_pc() to fail, and the host panics. A privileged user within a guest VM can issue a REP MOVS or REP STOS instruction against the local APIC page to cause a denial of service of the host and every other guest running on it. The flaw has existed since 2020 (illumos-gate commit e0c0d44e), and affects any illumos distribution prior to illumos-gate commit 696ecf8d.
CVE-2026-101130 1 Canva 1 Affinity 2026-10-09 3.6 Low
The Affinity by Canva application before 3.3.1 (October 2026 release) did not perform adequate bounds checking when parsing arrays of strings in Affinity document files, leading to a heap buffer over-read. A threat actor could craft an Affinity document that, when opened by a user in Affinity, could disclose the contents of adjacent heap memory in the document's text or result in an application crash.